What is the clinical indication for Lucas Device use?

Cardiac arrest in a patient with chest width less than 17.7 inches and sternum height between 6.7 and 11.9 inches.

2
New cards

What chest width range is required for Lucas Device use?

Less than 17.7 inches.

3
New cards

What sternum height range is required for Lucas Device use?

Between 6.7 and 11.9 inches.

4
New cards

What is the contraindication for Lucas Device use if a patient is too small?

The plunger cannot provide adequate depth of compressions.

5
New cards

What is the contraindication for Lucas Device use if a patient is too large?

The top part of the Lucas cannot click into the back plate.

6
New cards

What must happen to manual CPR while placing the Lucas Back Plate under the patient?

It is temporarily stopped.

7
New cards

Where is the Lucas Device Back Plate positioned under the patient?

Immediately below the armpits.

8
New cards

What is one method to place the Lucas Back Plate under the patient?

Lift the patient's torso and slide the Back Plate under from the head.

9
New cards

What is another method to place the Lucas Back Plate under the patient?

Log roll the patient and slide the Back Plate in from the side.

10
New cards

What should be done after the Back Plate is placed under the patient?

Continue manual CPR and turn on the Lucas device.

11
New cards

How is the LUCAS Upper Part removed from the bag?

Hold the handles on the Support Legs.

12
New cards

What confirms the Claw Locks are open when removing the LUCAS Upper Part?

Pulling the Release Rings once, then letting go of them.

13
New cards

What confirms the Lucas support legs are securely attached to the back plate?

Hearing a click when pulling up on it.

14
New cards

What is used to confirm the Suction Cup is immediately above the end of the sternum?

A finger.

15
New cards

How is the Lucas device repositioned if the Suction Cup is not correctly placed above the sternum?

By pulling the Support Legs to adjust the position.

16
New cards

What does adjusting the height of the Suction Cup set?

The Start Position.

17
New cards

What two things does the Start Position on the Lucas Device establish?

The point where the device starts its two-inch compressions and the point where it returns the chest for full recoil.

18
New cards

How is the Suction Cup pulled down to touch the patient's chest?

With two fingers, until the Pressure Pad touches the chest without compressing it.

19
New cards

What is done after locking the start position on the Lucas Device?

Check for proper position, adjust if needed, and press Start.

20
New cards

What should not delay Lucas Device application?

Applying the Stabilization Strap.

21
New cards

What is the Lucas Stabilization Strap used to secure?

The device itself, not the neck.

22
New cards

Where can the Lucas Stabilization Strap be placed relative to a c-collar?

On the outside of a c-collar.

23
New cards

What is secured in the patient straps at the end of Lucas Device application?

The patient's wrists.

24
New cards

What provider levels can apply the Lucas Device?

EMT-A, EMT-B, and EMT-P.