IPP operation limits with cover 4101 removed
-Max IPP oper. w/ cool down ____ minutes
-Req’d Interim cool down w/ IPP off ____ minutes
-Max oper. time after cool down ____ minutes
-Req’d cool down time to set time back to max w/ IPP of ____ minutes
35 / 20 / 35 / 20
FUEL CRITICAL ICAW is set at ____. Judgment of personnel and task being performed will dictate minimum quantity of fuel on aircraft before IPP operation.
1000 LBS
When _____ switch is set to on, ____ will automatically be performed.
28v BATT / SBIT
During SBIT, _____ and _____ lights will come on for approximately _____ and then go off.
28v low / 28v Discharge / 1 second
When ____ is complete, ____ light will come on and stay on
SBIT / 28v Discharge
If ____ light is flashing, IPP must be started within ____ to make sure IPP start is successful.
28v low / 30 seconds
If ____ light is flashing for more than ____, 28v battery will automatically go off. If automatic shutoff occurs, ____ switch must be set ____ and then 28v batter must be charged.
28v low / 60 seconds / 28v BATT / OFF
_____ should become available approximately ____ after 28v BATT switch has been set to ON.
Left MFD / 2 minutes
Operate UHF radio to local tower frequency ____
335.8
____ switch is not functional until after ____ is on (____ after 28v BATT switch was set to ON).
IPP / VMC / 15 seconds
____ switch must be held to ____ for ____ so ____ battery system can complete ____.
IPP / Start / 3 seconds / 270v / SBIT
____ and ____ lights will flash ____ time when IPP switch is set to ____ and shows lights are operating correctly.
270v low / 270v Discharge / 1 / Start
____ light should come on showing that 270v battery is discharging.
270v Discharge
If ____ light is on, IPP start can continue to be performed.
270v low
IPP switch will automatically move to ____ when released.
AUTO
If IPP has failure during start or operation, IPP should automatically ____.
Shutdown
Selecting ____ will not stop start sequence.
IPP OFF
IPP start sequence can only be stopped before ______ comes on solid by pushing ________ light button (emergency shutdown).
COMBUSTER light / IPP EMER OFF FIRE
IPP will not enter ____ cool down when IPP EMER OFF FIRE light button is pushed.
2 minute
If IPP EMER OFF FIRE light button is pushed, ____ light must go off. If light does not go off, IPP EMER OFF FIRE light button must be pushed again, and then ____ light must be inspected again.
270v Discharge / after 5 seconds
IPP combustor light will become solid when IPP is at command speed for standby mode (approximately ____ after START is selected).
30 seconds
IPP will have ______ during normal operations and can be heard.
Speed fluctuations
If ____ does not become available within ____, IPP must be shutdown immediately and troubleshooting performed.
Left MFD / 5 minutes
Ensure ____ indicator light is ____ when IPP combustor indicator light ______ and comes on solid.
270v Discharge / not on / Stops Flashing
Ensure ____ indicator light is not on ____ after IPP combustor indicator light comes on solid.
28v Discharge / 15 seconds
ENGINE INDICATIONS AND PARAMETERS PRIOR TO START
THRUST
HYD A
N1 RPM
OIL
FF (FUEL FLOW)
HYD B
NOZZLE
N2 PRM
EGT
COLOR VALUE
Red 000
Yellow N/A
Green less than 5%
Red less than 20 psi
Green 000
Yellow N/A
Green 100 to 106% open
Yellow less than 5%
Green uncalibrated between 20-60 degrees C
Maximum ESG Operation time
Engine can be motored maximum of ____.
2 minutes
Minimum IPP operation time
IPP must be operated minimum of ____ before motoring engine.
1 minute
ICC overheating
If ____ attempts are made in 120 minute period, ESG must have ____ cool down or ____ of IPP operation to decrease ____ and ____ Temperature.
2 Start / 120 minute / 10 minutes / ICC1 / ICC2
Component Overheating
If overheating component ICAW are asserted _____ sequence must be stopped and ____ must continue to operate to decrease component temperature.
motoring / IPP
Engine start is not recommended until after ____ of PCD is on (approx. ____ after IPP start)
Right side / 2 minutes
PARKING BRAKE must be cycled form ____ position to ____ positing and then to PARKING BRAKE position to engage.
Parking brake / OFF
Engine can be motored ____ time with GEN HOT 1&2 ICAW shown. If GEN HOT 1&2 ICAW ____ go away during ____ motor, motoring must be stopped to troubleshoot
1 time / does not / 2 minute
Engine must not be motored with ____ HOT ICAW showm
FUEL
Engine can be motored with GEN OIL FAIL 1&2 ICAW but must go away within ____ or engine motoring should be stopped. Engine motoring can be tried for a ___ attempt but also must go away within ____. If ICAW is still present after ____ motoring must be stopped to troubleshoot.
45 seconds / 2nd / 45 seconds / 45 seconds
When motoring, monitor engine indications of PCD engine page and make sure ____ RPM stabilizes at ____% RPM’s.
N2 / 11-19%
ICAW’s Before Engine Operation
_______ ICAW = Engine motoring must be performed
_______ ICAW = Engine must not be operated
GEN HOT 1&2
FUEL HOT
ICAW’s During Engine Operation
________ ICAW = If ICAW does not go away when engine gets to idle, engine operation must be stopped to troubleshoot
GEN OIL 1&2
If ETR higher then idle is required, engine must be operated for a minimum of ____ before advancing throttle.
2 minutes
IPP must be operated for minimum of ____ before engine start.
1 minute
Fuel Feed tank temperature must be more than ____ prior to engine start.
-18 Degrees C
Oil pressure can decrease into ____ range for approximately ____ during start sequence, and then rebound into the ____ range.
Red / 3 seconds / Green
Oil pressure should increase with increasing ____ RPM and when above ____ PSI, oil pressure gauge will turn green and ____ gauge will turn yellow.
N2 / 15 PSI / ETR
Engine start is not permitted if tailwinds is more than _____.
30 knots
If engine motoring was performed, engine N2 must be ____ before engine operation can be performed.
0%
Engine ____ RPM must always be ____ prior to switching engine states.
N2 / 0%
If ambient temperature is less than ____, 2 minute motoring must be accomplished.
0 degrees F
If engine start is less than ____ of abnormal engine shutdown or less than ____, but greater than ____ from normal shutdown, ____ engine motoring must be performed prior to engine start that follow.
6 hours / 6 hours / 20 minutes / 2 minute
Engine Start will ____ if ____ RPM does not get to ____% withing ____ or ____% withing ____.
AUTO Abort / N2 / 20-22% / 45 seconds / 55% / 150 seconds
After engine start ensure ____, ____ and ____ are off.
DAS / EOTS / RADAR
Engine must have been at idle (less than ____) for minimum of ____ before shutdown, to let engine cool down.
15% ETR / 5 minutes
If vehicle system IBIT is performed during engine operation, engine must be operated for ____ after IBIT is completed.
15 seconds
FPS fire bottle will automatically release approximately ____ after fire is detected in IPP or IPP exhaust bays.
10 seconds
FPS fire bottle will not release if BATT switch is set to ____
OFF