AUTOMATIC PROCESSOR

0.0(0)
studied byStudied by 2 people
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
Card Sorting

1/111

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

112 Terms

1
New cards
Automatic processing units
___________ standardize the processing of radiographs with consistency and efficiency.
2
New cards
Automatic Processor
also known as “dry to dry” system
3
New cards
1942
(year)

First automatic x-ray film processor was introduced by Pako
4
New cards
120 films
First automatic x-ray film processor Can process _______ per hour
5
New cards
First automatic x-ray film processor
Uses special film hanger
6
New cards
40 minutes
First automatic x-ray film processor

\
Approximately ______ total cycle time
7
New cards
1956
transport rollers were introduced by Eastman Kodak Company
8
New cards
(1) 10 ft.

(2) three quarters
transport rollers

\
_______ long and weighs nearly _______ of a ton
9
New cards
6 to 7
transport rollers

\
______ min. processing time
10
New cards
1965
90 second rapid processing by Eastman Kodak Company
11
New cards
1965 – 90 second rapid processing by Eastman Kodak Company
Development of new chemistry and emulsion and faster drying permitted by the polyester film base
12
New cards
1987
Konica introduce 45 second automatic processing
13
New cards

1. Control of temperature
2. Agitation of chemical solutions
3. Replenishment
4. Minimum spilling of chemicals as film moves from tank to tank
5. Transportation of film through system remains constant
6. Time-temperature relationship
7. Compact in size
8. Strategic placement
Requirements for automatic processor (8)
14
New cards
Control of temperature
Requirements for automatic processor

\
\- Helps maintain adequate density and contrast
15
New cards
* Agitation of chemical solutions
* Minimum spilling of chemicals as film moves from tank to tank
Requirements for automatic processor

\
\- Provides thorough mixing of chemical solutions
16
New cards
Replenishment
Requirements for automatic processor

\
\- Maintains volume and strength of solution
17
New cards
Transportation of film through system remains constant
Requirements for automatic processor

\
\- Controls length of time film is in developer and fixer
18
New cards
Time-temperature relationship
Requirements for automatic processor

\
\- Maintains consistency with all processor system
19
New cards
Compact in size
Requirements for automatic processor

\
\- Requires very little space to operate
20
New cards
Strategic placement
Requirements for automatic processor

\
\- Reduces time spent by radiographers travelling to and from the darkroom area
21
New cards
Glutaraldehyde
Special chemical hardener added to developer solution in automatic processing
22
New cards
22 to 24 seconds at 92 to 94 degrees Farenheit
Time-Temperature Relationship

\
___________ seconds at ___________ degrees Farenheit
23
New cards

1. Transport system
2. Recirculation system
3. Replenishment system
4. Wash system
5. Dryer system
6. Electrical system
Systems That Compose the Automatic Processor
24
New cards
Transport System
Moves the film through the processor
25
New cards
Transport System
Transports film through various stages at precise time intervals
26
New cards
Transport System
Controls the time in which the film is immersed in each wet chemistries
27
New cards
(1) speed

(2) constant
The _______ at which the film is moved through the processor must remain _______.
28
New cards
transport system
The ___________ agitates the solution and helps maintain the temperature.
29
New cards
* Rollers
* Transport rack
* Drive
Transport System’s Subsystem (3)
30
New cards
Rollers
steer film movement
31
New cards
Transport rack
rollers and guide shoes to move and change direction of film
32
New cards
Drive
provide power to turn rollers at precise rate
33
New cards
* Transport rollers
* Master rollers
* Planetary rollers
Roller Assembly (3)
34
New cards
Transport Rollers
1 inch in diameter
35
New cards
Transport Rollers
Positioned opposite to each other
36
New cards
Transport Rollers
Positioned offset from one another
37
New cards
Master Rollers
3 inches in diameter
38
New cards
Master Rollers
Also known as “solar” roller
39
New cards
Planetary Rollers
Number of rollers that surrounds the master roller
40
New cards
Transport Rack Assembly
where Most transport rollers are positioned
41
New cards
Transport Rack Assembly
They are easily removable and provide for convenient maintenance and efficient cleaning of the processor
42
New cards
“Turn-around” Assembly
Turn the film around in the bottom of the tank
43
New cards
“Crossover” Assembly
Moves the film from one to tank to another
44
New cards
“Guideshoes”
Special devices that guide the film to change direction
45
New cards
“Guideshoes”
For a 180 degrees bending of film
46
New cards
“Squeegee” Assembly
Squeeze the excess developer from the wet film emulsion
47
New cards
Drive System
Transfer power to transport rack and drive the rollers
48
New cards
Drive System
Used to connect the mechanical energy of the drive motor to drive mechanism of the rack assembly
49
New cards
fractional horsepower drive motor
Power for the transport system is provided by _______________
50
New cards
(1) shaft

(2) 10 to 20 rpm

(3) gear reduction assembly
The ________ of the drive motor is usually reduce ________ through ___________
51
New cards
* Belt and pulley
* Chain and sprocket
* Gears
3 way (means) by which transfer of power to transport rack can be accomplished
52
New cards
Recirculation System
Provides continuous mixing of the chemicals
53
New cards
Recirculation System
Continuous agitation and mixing play an important role in maintaining proper temperature and strength of the solutions.
54
New cards
temperature and strength
Continuous agitation and mixing play an important role in maintaining proper _____________ of the solutions.
55
New cards
* Heater
* Thermostat
* filters
Recirculation System is composed of:
56
New cards
95 degrees F (35 C)
Temperature control system

\
Optimal temperature is ______________
57
New cards
Thermocouple or thermistor
A thermostatically controlled heating element is in the developer tank
58
New cards
100
Filters

\
_______ um – to trap fleck of gelatin that are dislodge from the emulsion because they can cause artifacts
59
New cards
tanks and rollers
Filters

\
Not 100% efficient, so cleaning the ___________ is needed
60
New cards
Filters
Not necessary in the fixer solution
61
New cards
Filters
_______ are placed throughout replenishment system
62
New cards
Replenishment System
Adds solution to the developer and fixer as each film is processed
63
New cards
(1) shorter

(2) always
The _______ dimension of the film should _______ be against the side rail to maintain proper replenishment rate.
64
New cards
Replenishment System
Serves to maintain the volume and strength of the solutions
65
New cards
(1) not

(2) continually
Replenishment System

\
Wash water is _______ recirculated, it is _______ replaced by fresh tap water
66
New cards
Microswitch
Activates the pump that sends replenisher solution to the tank
67
New cards
(1) length of time

(2) how long
The _________ it takes for the film to enter the system determines _________ the replenisher pump will operate.
68
New cards
(1) stable

(2) tackiness
Adequate replenishment keeps the chemical activity ________ and helps prevent ________ of the film
69
New cards
control replenishment
The direction of travel for a particular film size becomes an important key to _____________
70
New cards
(1) 60 to 70 mL

(2) 100 to 110 mL

(3) 14
Replenishment Rate

\
____________ of developer and ____________ of fixer for every _______ inches of film
71
New cards
increases
Increase in replenishment rate _________ contrast
72
New cards
decreases
Decrease in replenishment rate __________ contrast
73
New cards
Wash System
Removes excess chemicals
74
New cards
developed silver halide crystals
Wash System

\
Finished film must contain only ____________________
75
New cards
deterioration
Wash System

\
All excess chemicals must be washed away to prevent _________ of the film after it is stored
76
New cards
Wash System
Tap water is sufficient
77
New cards
Dryer System
Blows hot air across the surface of the film to enhance drying on the surface
78
New cards
110 and 120
Dryer System

\
Temperature of air is approximately __________ degrees Fahrenheit
79
New cards
blower,

ventilation ducts,

drying tubes,

exhaust fan
Dryer System

\
Consist of __________ (4)
80
New cards
Dryer System
To remove surface moisture as rapidly as possible
81
New cards
dehumidifier
Dryer System

\
The air continually dried by a __________
82
New cards
(1) recirculate

(2) vented
Most of dry air is ________ however the dryer must be ________ to release built-up air as new air is pulled into the system
83
New cards
(1) Damp or wet radiograph

(2) emulsion
________________ picks up dust, becomes sticky and the ___________ is destroyed
84
New cards
Dryer System
Completely extracts residual moisture
85
New cards
low
Sucks in room air, therefore the room air is at _____ humidity vents hot moist air outside
86
New cards
(1) 3

(2) 2500
Dryer System

\
________ heating coils uses approximately _______ watt
87
New cards
Damp film
___________ indicates Automatic Processor malfunction or mostly depletion of glutaraldehyde
88
New cards
Electrical System
Distributes fused power to each system
89
New cards
Electrical System
Provides power to thermal and mechanical components, electrical component
90
New cards
Fuse box
Electrical System

\
\- only component significant to radiographer
91
New cards

1. Routine checks and cleaning of the transport rollers by lifting the racks of the tank
2. Careful examination and adjustment of guideshoes
3. Cleaning and replacement of filters throughout the processor unit
Maintaining the Processing Unit (3)
92
New cards
true
Regular maintenance procedures are required for consistency in performance of processors.
93
New cards
Maintaining the Processing Unit
Temperature readings, water flow, drainage check daily maintenance
94
New cards
Maintaining the Processing Unit
Check the numerous filters
95
New cards
true
Replenishment rate and microswitch control must be on routine checklist
96
New cards
Rapid Processing
Processing as low as 30 seconds
97
New cards
Rapid Processing
Usually used in angiography procedures, emergency, surgery, special procedures where time is critical
98
New cards
Rapid Processing
Uses special chemicals
99
New cards
Rapid Processing
Chemicals are concentrated, and temperatures are high
100
New cards
Extended Processing
3 minute processing time