1/41
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
Design of a Pressurized Irrigation System – Part A: Sprinkler Irrigation
PNS/BAFS/PAES 223:2017
average sprinkler pressure of a lateral
average pressure
pressure required to overcome the elevation difference between the water source and the sprinkler nozzle, to counteract friction losses and to provide adequate pressure at the nozzle for good water distribution
design pressure
numerical value on the uniformity of application for agricultural irrigation systems
distribution uniformity
time required to cover an area with one application of water
irrigation period
delivers water from the source to the pipe system at an adequate capacity
pump unit
consists of screen openings considerably lower than the nozzle diameter to prevent nozzles from clogging
filtration system
device of various nozzle sizes which sprays water over the ground or crop.
sprinkler
pipes which convey water from the pump to the laterals
Mainline and Submainlines
deliver water from the mainlines or submainlines to the sprinklers
lateral
type of sprinkler usually made of brass, stainless steel, aluminium and heavy duty plastic
impact sprinkler
type of sprinkler which are mostly used for landscape irrigation
Gear-driven sprinklers
type of sprinkler used for solid set, portable and semi-portable systems in agriculture as well as for landscape irrigation
rotor-type sprinklers
type of sprinkler with built-in flow controller, making it suitable for undulating terrain. It also has no moving parts and a unique flow pattern.
stationary sprinkler
Stationary sprinkler has nominal discharge covering the range of
280 to 1400 l/hr
The application rate shall always be _______ the basic infiltration rate of the soil.
less than
_______ shall be laid up and downhill.
Mainlines
______ shall be laid across slope or nearly on the counter.
Laterals
For multiple lateral operation, lateral pipe sizes shall be limited to not more than _____ diameters.
two
Sprinkler irrigation is not suitable for soils with an intake rate of less than ______ .
3 mm/hr
operate with sprinklers set in a fixed position
set system
sprinklers operate while moving in either a circular or straight path.
Continuous Move System
sprinklers that must be moved manually through a series of positions during the course of irrigation
Periodic-Move System
composed of portable or buried pipe with valve outlets at intervals for attaching the portable laterals.
Hand-Move System
Side-roll lateral system, End-tow lateral system, Gun and boom sprinkler system
Mechanical-Move System
Portable, Semi-portable, Drag-hose type
Hand-Move System
the lateral pipes are rigidly coupled and each joint of pipe is supported by a large wheel where the lateral line forms the axle for the wheels. This is mechanically moved by an engine mounted at the center of the line.
Side-roll lateral system
consists of rigidly coupled lateral pipe connected to a buried mainline positioned in the center of the field. Laterals are towed lengthwise over the mainline from one side to the other in an “s” form
End-tow lateral system
–nozzles are attached to long discharge tubes and rotated by means of a rocker arm drive
Gun and boom sprinkler system
Solid-set, Permanent Buried, Sequencing-Valve Laterals
Fixed System
Maximum sprinkler spacing for wind speed of up to 10 kph (rectangular pattern)
40% between sprinklers, 65% between laterals
Maximum sprinkler spacing for wind speed of 10-15 kph (rectangular pattern)
40% between sprinklers, 60% between laterals
Maximum sprinkler spacing for wind speed of above 15 kph (rectangular pattern)
30% between sprinklers, 50% between laterals
Maximum sprinkler spacing for wind speed of up to 5 kph (square pattern)
55%
Maximum sprinkler spacing for wind speed of 6-11 kph (square pattern)
50%
Maximum sprinkler spacing for wind speed of above 13-19 kph (square pattern)
45%
The total pressure variation in the laterals, if practicable shall not be more than _____ of the design pressure.
10%
The allowable friction loss in the laterals is _____ of the average pressure.
20%
The velocity in the main line shall be less than or equal to _____
2 m/s
Standard pipe length
6m
Maximum flow velocity for rigid PVC pipes should not exceed
1.5 m/s
Maximum flow velocity in the plastic pipes should not exceed _____
1.5 m/s