Plumbing (C-36) Practice Exams

0.0(0)
studied byStudied by 0 people
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
Card Sorting

1/99

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

100 Terms

1
New cards

28.0 degrees

The boiling points at 0 degrees gas pressure in Fahrenheit are: Ammonia (NH3):

2
New cards

110.50 degrees

Carbon dioxide (C2H5CO2):

3
New cards

55.6 degrees

Ethyl Chloride (C2H5CL)

4
New cards

21.7 degrees

Freon (F-12) (CC12F2)

5
New cards

2.31

(Note: 1.0 / 0.433 = 2.31)

(Note: 1.0 / 2.31 = 0.433)

One pound of pressure per sq. in. of water equals ______ feet of water at 62 degrees F.

6
New cards

0.433

(Note: 1.0 / 2.31 = 0.433)

(Note: 1.0 / 0.433 = 2.31)

One foot of water at 62 degrees F equals ________ pounds pressure per square inch.

7
New cards

14.0 degrees

Sulfur Dioxide (SO2)

8
New cards

10.6 degrees

Methyl Chloride (CH3CL)

9
New cards

10.0 degrees

Freezol (iso-butane) (CH3) (3CH)

10
New cards

27,000 grains per regeneration cycle

What is the minimum size water softener that may be used for a one inch water line in order to prevent pressure drop?

11
New cards

4 ounces

(~7 IWC)

Gas pressures for gas systems vary widely. What is the working pressure normally used on hot water heaters installed at individual houses.

12
New cards

2,000 - 300

No more than ______ cu. ft. of fuel gas or ______ lbs. of liquefied petroleum gas may be stored inside.

13
New cards

Slotted plug core shut off valve

What type of valve is used to shut off the main from the service?

14
New cards

5"

A gas vent connector shall have a continuous rise from the appliance to the vent of not less than ____ per foot of length.

15
New cards

1/2".

The size of the supply piping outlet for any gas appliance shall be not less than:

16
New cards

-66

What is the specific gravity of natural gas?

17
New cards

6

A single-wall metal flue pipe installed to serve a gas fired water heater is required by code to have a min. clearance of _____ inches from any combustible type materials.

18
New cards

188 - 40

The melting point of propane is _______ degrees C. and the boiling point of propane is _______ degrees C.

19
New cards

138 - 0.0

The melting point of butane is _______ degrees C. and the boiling point of butane is _______ degrees C.

20
New cards

14".

Low pressure gas piping 1/2" is installed to convey gas at pressure not to exceed a water column of:

21
New cards

10,000 - 16

Mechanical ventilation must be provided when welding or cutting is done where there is less than ______ cu. ft. of air per welder, where the ceiling is less than ____ ft. high, or when working in confined quarters.

22
New cards

9"- 4"

Earthquake security straps for a hot water heater shall be installed _____ from the top of the tank and ____ from the bottom.

23
New cards

top of boiler.

Placement of safety valves on a boiler is on the:

24
New cards

1/2".

The size of the gas supply piping outlet for a recessed oven cannot be less than:

25
New cards

20

Oxygen cylinders must be stored at least ____ ft. from fuel gas cylinders or combustible materials.

26
New cards

1-1/2"-16 gauge.

The minimum size strap for a hot water heater is:

27
New cards

3 feet.

The maximum distance from a gas appliance that the shut off valve may be is:

28
New cards

18

Gas water heaters burning not more than 40,000 BTU's per hr. may be connected with approved metal tubing connectors having a nominal diameter of 3/8" and an overall length not to exceed _____ inches.

29
New cards

7

According to Code, exit terminals of mechanical draft systems must be located a minimum of ____ feet above grade when adjacent to public walkways.

30
New cards

Type C vent.

A gas vent pipe which passes through the roof of a building must be provided with a vent cap. According to Code, it must not obstruct or reduce the effective cross-sectional area of the vent outlet and can be used on all but a:

31
New cards

1200

__________ degrees F. is the approximate combustion point of natural gas.

32
New cards

6'

Maximum length of any gas flexible connector is ______.

33
New cards

1/2".

The water supply piping should be sized accordingly. Concealed pipe within a wall going to a fixture is:

34
New cards

Only A and B are applicable:

(A) The piping and equipment between the street gas main and the gas piping system inlet;

(B) Piping and equipment which is under the control and maintenance of the serving gas supplier.

The term "service piping" refers to which of the following?

35
New cards

1/2".

The minimum size of a fixture water supply pipe for a single shower head is:

36
New cards

1/2".

The minimum size of a fixture water supply pipe for a domestic dishwasher is:

37
New cards

1/2".

The minimum size of a fixture water supply pipe for a wall hydrant is:

38
New cards

1/2".

The fixture supply pipe for women's restroom lavatories rated at 2 cwsfu each is ___ size.

39
New cards

5'.

Discharge from relief valves of liquefied petroleum piping systems shall be into open air and shall be horizontally away from any opening into a building which is below such discharge not less than:

40
New cards

3/4".

The water supply piping should be sized accordingly. The first section of a water pipe within a building is:

41
New cards

3/8".

The minimum size of a fixture water supply pipe for a bidet is:

42
New cards

1"

At the point where a 1/2" lavatory fixture branch joins a 3/4" urinal fixture branch pipe, the demand increases to 14 cwsfu and the pipe increases to ___ size.

43
New cards

1'.

Labels on copper tubing systems shall be permanently affixed to the tubing at walls, floors or partitions penetrations within:

44
New cards

3/4".

The water supply piping should be sized accordingly. Sillcock is:

45
New cards

1".

The minimum size of a fixture water supply pipe for a flush-valve toilet is:

46
New cards

1/2".

The minimum size of a fixture water supply pipe for a wall hydrant is:

47
New cards

1/2".

The minimum size of a fixture water supply pipe for a flush-tank urinal is:

48
New cards

underground.

Combination stop-and-waste valves are not allowed to be installed:

49
New cards

at the same location except where impractical.

Where more than one gas meter is set on a specific premises, they shall all be set:

50
New cards

80

An approved pressure-reducing valve must be installed in a water service pipe of a building, near where the pipe enters a building, when the street pressure of the water main providing potable water exceeds ____ pounds per sq. inch.

51
New cards

3/8".

The minimum size of a fixture water supply pipe for a lavatory is:

52
New cards

Quick-closing valves

Under normal conditions, a water hammer arrestor is required whenever certain valves are used, which of the following valves are of a type to require such a device?

53
New cards

Only B and C are approved tests:

(A) a minimum of 10 psi for 15 minutes.;

(B) at the discretion of the administrative authority to specify the pressure and duration of time.

The administrative authority shall inspect the test of fuel gas piping installations and the pressure required is:

54
New cards

the maximum hourly rating specified by the manufacturer.

The hourly volume of gas required at each piping outlet shall be taken as not less than:

55
New cards

3/4".

The minimum size of any gas piping outlet for a mobile home shall be;

56
New cards

1/2".

The minimum size of a fixture water supply pipe for a bathtub is:

57
New cards

1/2".

The minimum size of a fixture water supply for a kitchen sink is:

58
New cards

1/2".

The fixture supply pipe for women's restroom lavatories rated at 2 cwsfu each is ___ size.

59
New cards

3/4".

The water supply piping should be sized accordingly. Pipe for more than three fixtures or a branch is:

60
New cards

1/2".

The minimum size of a fixture water supply pipe for a combination sink and tray is:

61
New cards

1/2".

The water supply piping should be sized accordingly. Fixture branch pipe is:

62
New cards

3/4".

The minimum size of a fixture water supply for a flush-valve urinal is:

63
New cards

1/2".

The minimum size of a fixture water supply pipe for a hose bibb is:

64
New cards

1/2".

The minimum size of a fixture water supply pipe for a laundry tray with up to 3 compartments is:

65
New cards

6'.

Labels shall be spaced throughout copper tubing systems at maximum intervals of:

66
New cards

black letters on a yellow field.

Copper tubing systems shall be identified with an appropriate label to indicate the piping system conveys fuel gas. Labels shall be:

67
New cards

Only A and C apply:

(A) welded;

(B) flanged.

All joints in fuel gas piping shall be:

68
New cards

identified and labeled to show the fixture being served.

When valves are installed in locations which are not adjacent to the fixture or appliance being served, the valves must be:

69
New cards

gate valve (also known as a fullway valve)

Of the following valves, the one code-approved for a building water service line is the:

70
New cards

25

Flow pressure ranges from 8 psi for faucets and tank-type water closets to ___ psi for certain models of flushometer valve.

71
New cards

Flanged

Which of the following types of joints are not used to join copper tubing?

72
New cards

3/4".

The water supply piping should be sized accordingly. Pipe extending from the water main to water meter is:

73
New cards

1/2".

The minimum size of a fixture water supply for a service sink is:

74
New cards

one half inch diameter.

The minimum size of the supply piping outlet for any gas appliance shall not be less than:

75
New cards

the I.D.

Ferrous pipe (iron and steel) is measured by:

76
New cards

3

How many grades of wall thickness does the hard temper tubing come in?

77
New cards

14

How many threads per inch does a 1/2" pipe have?

78
New cards

White

Name the color used to denote brass pipe.

79
New cards

L

Name the medium wall thickness of copper tubing.

80
New cards

To change the direction of a soil or waste pipe from horizontal to vertical usually short quarter bends are used.

Which of the following is LEAST true?

81
New cards

Rigid stationary pipe clamps

What types of supports are used for PVC piping? Which of the following is LEAST true?

82
New cards

1136 sq. in.

The minimum floor area of a shower stall must be:

83
New cards

Where a trap can not be vented

The use of a deep seal trap is required in which of the following situations?

84
New cards

Never

Should a damper be installed in the vent to all gas water heaters as a matter of safety?

85
New cards

where those structures allow combustible construction.

ABS or PVC drainage installations are limited to residential construction:

86
New cards

PVC schedule 80.

Plastic piping from a septic tank to a drainfield located under paving shall be:

87
New cards

Vitrified clay pipe is ordered by the piece.

Which of the following is MOST FALSE when working with vitrified clay pipe?

88
New cards

Drainage pipe fittings are the same as water supply fittings.

Which of the following is LEAST true?

89
New cards

2 inches

What is the smallest diameter of pipe that should be used for floor drain waste lines?

90
New cards

Black

Name the color used to denote copper pipe.

91
New cards

4 hours

If the maximum test pressure is to be maintained at 160 psi, what is the minimum curing time for cemented joints on 2" PVC schedule 40 pipe with ambient temperature at 50 degrees F.?

92
New cards

DWV.

Copper tubing for both above and under ground drainage and vent piping shall have a weight of not less than that of copper drainage tube type:

93
New cards

Green

What color is the stripe of the thickest walled (Type K) copper tubing?

94
New cards

open floor drain.

A refrigerator must be drained into a/an:

95
New cards

Yellow

Type DWV drain copper tubing is marked with what color identification stripe?

96
New cards

a water pressure regulator is installed.

A pressure relief valve is required when:

97
New cards

80

The minimum schedule recommended for plastic pipe to be threaded is:

98
New cards

horizontal to vertical.

A sanitary tee may be used to change the direction from:

99
New cards

It's more durable

What is the main reason for using thick wall as opposed to thin wall copper pipe?

100
New cards

All of the above:

(A) galvanized pipe;

(B) plastic pipe;

(C) copper type K, L, or DWV.

Soil, waste and vent piping above ground within buildings over deleterious fill may be: