RA 9266
Practice of Architecture
March 17, 2004
Repeal RA 545
RA 545
Architecture Law of 1950
RA 386
Civil Code of the Philippines
June 18, 1949
RA 7160
Local Government Code of the Philippines
October 10, 1991
RA 876
The Philippine Arbitration Law
June 19, 1953
PD 1096
National Building Code of the Philippines (NBCP)
February 19, 1977
IRR latest Version — April 30, 2005
Repeal RA 6541
RA 6541
National Building Code of the Philippines (1972)
August 26, 1972
RA 9514
Fire Code of the Philippines
Revised Fire Code of the Philippines of 2008
December 19, 2008
Repeal PD 1185
BP 344
Enhancing the Mobility of Disabled Persons
February 25, 1983
IRR Latest Version — April 30, 2005
RA 1378
National Plumbing Code of the Philippines
PD 1067
Water Code of the Philippines (1977)
BP 220
Standards for Economic and Socialized Housing Projects
RA 7279
Urban Development and Housing Act
PD 1152
Philippine Environmental Code
RA 8293
Intellectual Property Code of the Philippines
RULE I (RA 9266)
Title, Policy Statement, Definition of Terms and Scope of Practice
RULE II (RA 9266)
Professional Regulatory Board of Architecture (PRBOA) Organization, Powers, and Function
RULE III (RA 9266)
Examination, Registration, and Licensure
RULE IV (RA 9266)
Practice of Architecture (Sundry Provisions)
RULE V (RA 9266)
Final Provisions
RULE 1 (PD 1096; NBCP)
General Provisions
RULE 2 (PD 1096; NBCP)
Administration and Enforcement
RULE 3 (PD 1096; NBCP)
Permits and Inspection
RULE 4 (PD 1096; NBCP)
Types of Construction
RULE 5 (PD 1096; NBCP)
Requirements of Fire Zones
RULE 6 (PD 1096; NBCP)
Fire Resistive Requirements in Construction
RULE 7 (PD 1096; NBCP)
Classification and General Requirements of All Buildings By Use or Occupancy
RULE 8 (PD 1096; NBCP)
Light and Ventilation
RULE 9 (PD 1096; NBCP)
Sanitation
RULE 10 (PD 1096; NBCP)
Building Protection Over Public Streets
RULE 11 (PD 1096; NBCP)
Protection of Pedestrians During Construction or Demolition
RULE 12 (PD 1096; NBCP)
General Design and Construction Requirements
RULE 13 (PD 1096; NBCP)
Electrical & Mechanical Regulations
RULE 14 (PD 1096; NBCP)
Photographic and X-Ray Films
RULE 15 (PD 1096; NBCP)
Prefabricated Constructions
RULE 16 (PD 1096; NBCP)
Plastics
RULE 17 (PD 1096; NBCP)
Sheet Metal Paint Spray Booths
RULE 18 (PD 1096; NBCP)
Glass and Glazing
RULE 19 (PD 1096; NBCP)
The Use of Computers
RULE 20 (PD 1096; NBCP)
Signs
RULE 21 (PD 1096; NBCP)
Final Provisions
1 slot / 10 units
Low income single detached living unit with individual lots not more than 100m2
1 slot / 8 units
Multi-family living units regardless of no. of stories with average living floor area of 50m2
Multi-family living units regardless of no. of stories with average living floor area of above 50m2 to 100m2
1 slot / 1 unit
Multi-family living units regardless of no. of stories with average living floor area of more than 100m2
Motels
1 slot / 10 rooms
Hotels
1 slot / 5 units
Residential Hotels and Apartels
1 slot / 100m2
Shopping Centers
1 slot / 150m2
Markets
1 slot / 30m2 of customer area
Restaurants, fast food outlets, bars and
beerhouses
1 slot / 20m2 of customer area
Nightclubs, supper clubs and theater-
restaurants
1 slot / 125m2 of gross floor area
Office Building
Other buildings in business and
commercial zones
1 slot / 20 beds
Pension/boarding/lodging house
1 slot / 50m2 of spectator area
Public Assembly Buildings
1 slot / 50m2 of congregation area
Places of Worship / Funerary Parlors
1 slot / 10 classrooms
Elementary schools, Secondary Schools, Vocational and Trade Schools
1 slot / 50m2 of gross floor area
Amusement Centers
1 slot / 100m2 of gross floor area
Clubhouse, beach houses, etc.
1 slot / 1000m2 of gross floor area
Factories, manufacturing, mercantile,
warehouses and storage bin
2 bus slots / hotel or theater restaurant
Tourist bus parking
1 slot / 5 classrooms
College and Universities
1 slot / 25 beds
Hospitals
1 slot / 4 alleys
Bowling Alleys
1 loading slot for every 5000m2 of gross floor area (minimum of 1 truck loading slot)
Stores, manufacturing, mercantile, wholesale and the like
1 truck loading slot
Hotels and Hospitals
1 Parking Lot / 50-100 slots (additional slot for every 100)
Accessible Parking Slots
TYPE I (Types of Construction)
Wood Construction
TYPE II (Types of Construction)
Wood Construction with protective fire-resistant materials (1 hour)
TYPE III (Types of Construction)
Masonry and Wood Construction
TYPE IV (Types of Construction)
Steel, Iron, Concrete, or Masonry Construction (1 hour)
TYPE V (Types of Construction)
Steel, Iron, Concrete, or Masonry Construction (4 hour)
Residential Dwellings
Group A
Divisions A1, A2
Zones R-1, R-2
Residentials, Hotels and Apartments
Group B
Divisions B1, B2
Zones R-3, R-4, R-5
Education and Recreation
Group C
Divisions C1, C2
Zones GI
Institutional
Group D
Divisions D1, D2, D3
ZoneS R-1, R-2
Business and Mercantile
Group E
Divisions E1, E2, E3
Zones C-1, C-2, C-3
Industrial
Group F
Division F-1
Zones I-1
Storage and Hazardous
Group G
Divisions G1, G2, G3, G4, G5
Zones I-2, UTS
Assembly Other Than Group I
Group H
Divisions H1, H2, H3, H4
Zones PRE, CUL
Assembly Occupant Load 1000 or More
Group I
Division I-1
Zones CUL, PRE
Accessory / Agriculture
Group J
Division J1, J2, J3
Zones A, AI, PUD
Group A - Division 1 (A-1)
Residential building/structure for exclusive use of single family
occupants including school or company staff housing;
single (nuclear) family dwellings;
churches or similar places of worship; church rectories;
community facilities and social centers;
parks, playgrounds, pocket parks, parkways, promenades and play lots;
clubhouses and recreational uses such as golf courses, tennis
courts, basketball courts, swimming pools and similar uses
operated by the government or private individuals as membership
organizations for the benefit of their members, families, and guests and
not operated primarily for gain.
Group A - Division 2 (A-2)
Residential building for the exclusive use of non-leasing occupants not
exceeding 10 persons including single-attached or duplex or
townhouses, each privately-owned; school dormitories (on
campus); convents and monasteries; military or police
barracks/dormitories; pre-schools, elementary and high schools,
provided that they do not exceed 16 classrooms; outpatient clinics,
family planning clinics, lying-in clinics, diagnostics clinics, medical
and clinical laboratories; branch library and museums;
steam/dry cleaning outlets; party needs and accessories (leasing
of tables and chairs, etc.).
Group B
Occupancies shall be multiple dwelling units including
boarding or lodging houses, hotels, apartment buildings, row
houses, convents, monasteries and other similar building each of
which accommodates more than 10 persons.
Group C
Occupancies shall be buildings used for school or day-care purposes, involving assemblage for instruction, education, or recreation, and not classified in Group I or in Division 1 and 2 or Group H Occupancies.
Group D - Division 1 (D-1)
Mental hospitals, mental sanitaria, jails, prisons, reformatories, and buildings were personal liberties of inmates are similarly restrained.
Group D - Division 2 (D-2)
Nurseries for full-time care of children under kindergarten age, hospitals, sanitaria, nursing homes with non-ambulatory patients, and similar buildings each accommodating more than five persons.
Group D - Division 3 (D-3)
Nursing homes for ambulatory patients, homes for children of kindergarten age or over, each accommodating more than five persons: Provided, that Group D Occupancies shall not include buildings used only for private or family group dwelling purposes
Group E - Division 1 (E-1)
Gasoline filling and service stations, storage garages and boat storage structures where NO WORK is done except exchange of parts and maintenance requiring NO open flame, welding, or the use of highly flammable liquids.
Group E - Division 2 (E-2)
Wholesale and retail stores, office buildings, drinking and dining establishments having an occupant load of LESS than one hundred 100 persons, printing plants, police and fire stations, factories and workshops using not highly flammable or combustible materials and paint stores without bulk handlings
Group E - Division 3 (E-3)
Aircraft hangars and open parking garages where NO repair work is done except exchange of parts and maintenance requiring NO open flame, welding or the use of highly flammable liquids.
Group F
ice plants, power plants, pumping plants, cold storage, and creameries, factories and workshops using incombustible and non-explosive materials, and storage and sales rooms for incombustible and non-explosive materials.
Group G - Division 1 (G-1)
Storage and handling of hazardous and highly flammable material.
Group G - Division 2 (G-2)
Storage and handling of flammable materials, dry cleaning plants using flammable liquids; paint stores with bulk handling, paint shops and spray painting rooms.
Group G - Division 3 (G-3)
Wood working establishments, planning mills and box factories, shops, factories where loose combustible fibers or dust are manufactured, processed or generated; warehouses where highly combustible materials is stored.
Group G - Division 4 (G-4)
Repair Garages
Group G - Division 5 (G-5)
Aircraft Repair Hangars
Group H - Division 1 (H-1)
Any assembly building with a stage and an occupant load of less than 1000 in the building.
Group H - Division 2 (H-2)
Any assembly building without stage and having an occupant load of 300 or MORE in the building.
Group H - Division 3 (H-3)
Any assembly building without a stage and having an occupant load of LESS than 300 in the building
Group H - Division 4 (H-4)
Stadia, reviewing stands, amusement park structures not included within Group I or in Division 1, 2, and 3 of this Group.