Quality Assurance (QA) = _____ of US to guarantee optimal image quality

eval

2
New cards

US should be based on _____ standards

objective

3
New cards

Objective = _____ = Factual = always the ____regardless

unbiased, same

4
New cards

Subjective = ____ by experience/belief = affected by _____ = ____ from person to person

influenced, opinion, varies

5
New cards

What 3 people inspect US machines

medical physicist, biomed engineer, US vendors

6
New cards

What are the 4 REQUIREMNETS for QA

  1. asses sys ____

  2. _____

  3. ______ maintenance

  4. _____ keeping

components, repairs, preventative, record

7
New cards

What are the 5 GOALS of QA?

  1. guarantee proper ____ of sys

  2. detect ____ changes

  3. ______ downtime

  4. _____ # of non-diagnostic exams

  5. reduce # of _____ exams

operation, gradual, min, reduce, repeat

8
New cards

The 3 devices used to perform a QA are the ____ equivalent phantom, ____ phantom, ___ ___/ ____ ____ phantom

Tissue, Doppler, Beam Profile/Slice Thickness

9
New cards

Tissue Phantom is used to eval ____ ___ imaging, _____ texture and _____ focus phased arrays

grey scale, tissue, multi

10
New cards

What are the 3 types of Doppler Phantoms

vibrating string, moving belt, flow phantom

11
New cards

The _____ _____ phantom determines the elevational + lateral resolution

slice thickness

12
New cards

Sensitivity = ability of sys to eval ____ lvl echoes

low

13
New cards

_____ sensitivity = all pins/solid/cystic struct in phantom on display and do NOT vary from 1 eval to another

normal

14
New cards

_____ sensitivity = output power/amp is set to max

Maximum

15
New cards

The ____ ____ is the area closet to the transducer where images are _____

Dead Zone, inaccurate

16
New cards

_____ freq transducers have a THINNER dead zone vs _____ freq transducer

higher, lower

17
New cards

A ______ ___ is useful to eliminate the dead zone

Standoff pad

18
New cards

Registration Accuracy = ability for sys to place reflectors in ____ ____

proper positions

19
New cards

_____ accuracy = placing reflectors at correct DEPTHS parallel to sound beam

Range

20
New cards

Horizontal Calibration = placing reflectors at correct position ______ to sound beam

perpendicular

21
New cards

_____ ______ Accuracy is imp in follow up/repeat exam w/ measurement

Distance Measurement

22
New cards

Focus = depth where beam is ______, Focal Zone = ____ the focus

narrowest, surrounds

23
New cards

Axial Resolution is determined by the ____ ____

pulse length

24
New cards

Axial Resolution = ability to tell apart objects that are ____ to the sound beam

parallel

25
New cards

_____ Pulses = improved axial res

shorter

26
New cards

Lateral Resolution is determined by the _____ _____

beam width

27
New cards

Lateral res = ______ _____

beam diameter

28
New cards

Lateral Resolution = ability to tell apart objects that are ____ or ____ ___ ___ to the sound beam

perpendicular, side by side

29
New cards

_____ is in reference to the ENTIRE image + eval if identical reflectors are the same brightness at diff depth

Uniformity

30
New cards

Display = _____/_____ of the monitor

brightness/contrast