ARCC - BU

0.0(0)
Studied by 4 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/174

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 1:15 PM on 9/24/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

175 Terms

1
New cards

This pump is used in dewatering tunnels, foundation pits, trenches, and similar locations

Submersible Pump

2
New cards

This is considered a fire pump usually used in high-rise buildings.

Turbine Pump

3
New cards

A type of sanitary pipe that is expensive and can last up to 100 years of use wherein it is usually used in high-rise buildings.

Cast Iron Pipe

4
New cards

A type of pump that displaces a set volume of water with each turn of the pump

Positive Displacement

5
New cards

Plumbing systems consist of the following, except;

Sprinkler System

6
New cards

A water distribution system that uses the pressure pumps from water mains or tanks to supply water to buildings

Upfeed Distribution System

7
New cards

A type of pump that is economical for low-volume facilities, and is commonly used in wells

Jet Pump

8
New cards

A type of pump that is most effective for transferring viscous or high-pressure liquids but is not suitable for handling abrasive liquids

Rotary Pump

9
New cards

The minimum fixture feed pipe size for a water heater.

¾”∅

10
New cards

A type of pipe that has strong resistance to corrosion.

Copper Pipe

11
New cards

This type of pipes and fittings is manufactured from synthetic resins derived from fossil fuels, such as coal and petroleum.

Plastic Pipe

12
New cards

A wastewater containing toilet or urinal waste.

Blackwater

13
New cards

Wastewater from washing machines containing dirty diaper loads, as well as from kitchen sinks and dishwashers, is typically prohibited from reuse.

Dark Graywater

14
New cards

The backwash water generated from reverse osmosis water treatment processes and condensation from cooling coils.

Clearwater

15
New cards

Materials used for sanitary piping systems consist of the following, except;

Aluminium

16
New cards

Sanitary pipes that are not suitable for underground use and must be installed at least 152 mm above ground level.

Steel Pipe

17
New cards

A type of pump usually seen on fire trucks with 175psi.

Jockey Pump

18
New cards

The dimensions of the water pump room serving an area of 18,500 m2 and below.

3.00m x 4.00m

19
New cards

The dimensions of the fire pump room serving an area of 18,500 m2 - 93,000 m2

9.00m x 8.00m

20
New cards

The screening, sedimentation, filtration, etc. of waste water and solids from a sewer, and the disposal of settled sludge in digestion tanks or on drying beds

Disposal System

21
New cards

The minimum horizontal distance of the septic tank from water supply wells and bodies of water.

15.20 m

22
New cards

Means of disposal used for Gross floor area less than 2,000 m2 .

Septic Tank

23
New cards

Means of disposal used for Gross floor area of 2,000 m2 and above.

STP

24
New cards

The Fire Suppression System is used for buildings 4-storey high and below

Standpipe

25
New cards

Sprinkler heads that have a spray pattern that can cover up to 400 square feet, require fewer heads but higher water pressure and water flow rate.

Extended Coverage Sprinkler Head

26
New cards

Which among these sources of energy is considered a non-renewable source of energy? (CHATGPT ANSWER)

Nuclear

27
New cards

A heat energy is generated and stored within the Earth. It can be harnessed for various uses such as heating buildings, generating electricity, and other applications.

Geothermal energy

28
New cards

What kind of transformer is used for a photovoltaic energy source so that it may be used in the building?

Step up

29
New cards

Which of the following is not a space inside a powerhouse?

Panelboard room

30
New cards

These are high-voltage power lines that carry electricity over long distances from power plants to substations.

Transmission Line

31
New cards

These are low-voltage power lines that carry electricity from substations to end users, such as homes and businesses.

Distribution Line

32
New cards

This is the overhead or underground electrical line that connects the utility's distribution line to the customer's premises.

Service drop

33
New cards

A structure that supports overhead power lines, ensuring the distribution of electricity

Electric pole

34
New cards

A structural unit or components which guard the turbine, generator, and other electrical components

Powerhouse

35
New cards

A central location in a building where electrical equipment, switchboards and connections are managed

Main electrical room

36
New cards

In what floor is an on-site powerhouse ideal to be located in a building with a podium?

3rd to 4th floor

37
New cards

What is the height requirement for a generator room where an exhaust can be placed?

4.0 meters

38
New cards

It is where the panelboards are usually located:

Electrical room per flr

39
New cards

What is the minimum wire size recommended for lighting circuits (TW, THW, THWN)?

2 - 3.5 mm^2

40
New cards

A type of conduit that provides excellent protection for electrical wiring in harsh environments.

Rigid Steel Conduit (RSC)

41
New cards

A type of overcurrent protection device that automatically interrupts an electric circuit to prevent damage from excess current

Circuit Breaker

42
New cards

An open metal framework for supporting insulated electrical wires

Cablebus

43
New cards

A tube, pipe, or duct for enclosing and protecting electric wires and cables

Conduit

44
New cards

A type of electric circuit having a single path for current flow.

Series Circuit

45
New cards

What is the maximum height difference between outdoor and indoor units for a multi-split air conditioning system?

50 meters

46
New cards

What is the maximum pipe length from the first separation tube to the farthest indoor unit?

60 meters

47
New cards

A mechanical installation system providing warmed, cooled, clean and otherwise treated air into the habitable spaces of a building

Air-conditioning System

48
New cards

Also known as the outdoor unit of an air-conditioning system

Condenser

49
New cards

What is the minimum height of a chilled water plant for buildings of moderate size?

3.66 meters

50
New cards

Which of the following is not a type of AHU for split-type systems?

Window-type

51
New cards

The 4th method of the body to give off heat

Evaporation of perspiration

52
New cards

Describes a delicate balance of pleasant feeling in the body produced by its surroundings.

Comfort

53
New cards

The refrigeration components of an air conditioning system are composed of the following:

Evaporator, Compressor, Condenser, Refrigerant Metering Device

54
New cards

A type of duct-free air-conditioning system that is composed of a single unit, usually mounted or installed in a wall opening

Window Type System

55
New cards

A type of outdoor unit for multi split systems that can be stored indoors?

Water cooled System

56
New cards

A part of a ducted air-conditioning system that is usually located on the rooftop and outdoors.

Cooling Tower

57
New cards

What is the maximum height for a chilled water plant for large buildings?

4.88 meters

58
New cards

The applicable area of a 4.00hp wall mounted aircon type?

50

59
New cards

Typical chiller area for a commercial building with 10 000 sqm. total floor area?

150

60
New cards

What is the required chiller area for hotels with 5 000 sqm. total floor area?

50

61
New cards

What is the required chiller space for auditoriums and theaters with 3 000 sqm. total floor area?

60

62
New cards

A part of a ducted air-conditioning system which is required per floor

Air Handling Unit

63
New cards

The fan room must only be placed on the basement floor?

False

64
New cards

What is the recommended cooling tower area for commercial buildings with 10 000 sqm. total floor area?

40

65
New cards

What is the recommended cooling tower area for auditoriums with 10 000 sqm. total floor area?

60

66
New cards

What is the recommended cooling tower area for apartments and dormitories with 5 000 sqm. total floor area?

15

67
New cards

A type of duct-free air conditioning system that consists of one outdoor unit for multiple indoor units? (CHATGPT ANSWER)

Multi Split Type System

68
New cards

The three direct ways of the human body to give off heat is through conduction, convection, and radiation?

True

69
New cards

What is the best elevator for a residential building with more than five (5) floors?

Electric Traction Elevator

70
New cards

Parallel escalator configuration is appropriate for a multi-story office project.

False; it should be cross-over escalator

71
New cards

If an escalator is to be integrated in your design project, what angle of inclination will it be?

30

72
New cards

A row of elevators in a high-rise building controlled by a common operating system and responding to a single call button.

Elevator bank

73
New cards

For the LRT 4 terminal station project, what type of elevator would you recommend for passengers?

Hydraulic Elevator

74
New cards

Who is the inventor of the safety elevator?

Elisha Otis

75
New cards

For a 12-story school building, what type of elevator would you recommend for its users?

Electric Elevator

76
New cards

A general term used for an elevator used to move furniture, building material, goods, etc., industrial or any building; an elevator for carrying heavy cargo.

Freight Elevator

77
New cards

If a 16-story office tower has four (4) lifts, what is its classification based on the rule of thumb office lift service adopted by Otis?

Fair

78
New cards

Which of the following elevators is the most suitable for the occupants in a high-rise office building?

Electric passenger elevator

79
New cards

This is a type of lighting design where the overall lighting of a room is generally used for safety and basic visual recognition.

Ambient lighting

80
New cards

This type of lighting design is usually used to highlight displays or features like artworks, architectural features, retail displays, and signs. Generally used in museums and retail stores.

Focal or accent lighting

81
New cards

If a client is looking for a lighting design used for the performance of a specific task, what would you, as an architect, recommend?

Task lighting

82
New cards

This type of lighting design serves mainly as an ornament for a space.

Decorative lighting

83
New cards

This lighting system produces 90-100% light. It is usually used in offices and classrooms.

Direct Lighting

84
New cards

This lighting system is used to create a soft and dim lighting where the ceiling distributes 90-100% of the light.

Indirect Lighting

85
New cards

In this lighting system, light is distributed in two ways where the majority of it (60-90%) is directed to the ceiling.

Semi-Indirect Lighting

86
New cards

In this lighting system, light is distributed in two ways where the majority of it (60-90%) is directed downwards.

Semi-Direct Lighting

87
New cards

This lighting system on the other hand, creates an almost 50-50 distribution of light. It creates light that is brighter than semi-indirect, but softer than direct lighting.

Direct-Indirect Lighting

88
New cards

A science of sound that deals with the production, control, transmission, reception and effects of sound.

Acoustics

89
New cards

This sound phenomena happens when a change in direction occurs while entering a different medium.

Refraction

90
New cards

This happens when a soundwave encounters a sharp discontinuity in the density of its medium, and some of its energy is reflected.

Reflection

91
New cards

An architect would be designing a classroom where understanding of speech is vital. The following are building materials that the architect could consider using, which material would be the BEST.

Hardwood

92
New cards

The following materials are examples of reflective materials. Which among these materials have 100% reflected sound?

Granite stone

93
New cards

This sound phenomena reduces and absorbs sound.

Absorption

94
New cards

If you were to design an office, what could be a good material to absorb sound and control noise?

Acoustic Wall Panel

95
New cards

Absorptive materials are generally used in which of these spaces?

Cinema

96
New cards

This sound phenomena occurs when there is bending of waves around small obstacles and the spreading out of waves beyond small opening.

Diffraction

97
New cards

This is the reflection of sound off a convex or uneven surface.

Diffusion

98
New cards

Diffusive Materials are good materials for dispersing sound. The following materials have these characteristics, EXCEPT.

Hard materials with smooth surfaces

99
New cards

Which of the spaces below uses diffusive materials?

Opera

100
New cards

The idea that there exists a characteristic time for sound to die out in a room.

Reverberation Time