A red placard with the number 3 on the back of a tanker indicates:
Flammable liquid
You arrive first at a tanker rollover marked with a Class 8 placard, product leaking. Your first action as an Operations-level responder is to:
Isolate the area and establish command
An oval, smooth-surface, non-pressurized tanker carrying gasoline is classified as:
MC-306/DOT-406
A tanker with visible reinforcing rings around its circumference most likely carries:
Corrosives
Shipping papers for a highway hazmat load are called the _ and kept by the _:
Bill of Lading; the driver
On a train, hazmat shipping papers are located:
In the caboose with the conductor (Waybill/Consist)
Vapor density greater than 1 means a gas will:
Sink and pool in low areas
Specific gravity less than 1 means a liquid will:
Float on water
A BLEVE occurs when:
A pressurized container holding liquefied gas fails from external heat
Operations-level responders are limited to which type of action?
Defensive only
Which decon type is performed immediately with no formal setup, for life-threatening contamination?
Emergency decon
Technical decon takes place in the:
Warm zone
The first unit on scene at a hazmat incident should assume:
Defensive position
In the EVADE acronym, 'A' stands for:
Assume a secondary device is present at all scenes
In the EVADE acronym, 'D' stands for:
Do not become part of the problem
Level __ PPE is required for an unknown environment per HAZWOPER:
Level B
A chemical that moves through PPE at the molecular level with no visible hole is:
Permeation
An underflow dam is used when the spilled product:
Floats on top of water
An overflow dam is used when the spilled product:
Sinks below water
The minimum number of responders that may enter a contaminated area is:
2 (never less than two)
A backup team must be ready to enter within approximately:
A minute
REL stands for:
Recommended Exposure Limit
TWA stands for:
Time-Weighted Average (8hr/day, 40hr/week)
IDLH stands for:
Immediately Dangerous to Life or Health
The green-bordered pages of the ERG are used to find:
Evacuation distances
The orange-bordered pages of the ERG are used to find:
Emergency response guides
Carbon monoxide is best described as having:
No odor and no taste
The antidote for hydrogen cyanide poisoning is:
Hydroxocobalamin
A cyanide antidote kit should be administered:
In a prehospital setting
Span of control refers to:
How many people one supervisor can effectively manage
Which ICS position has authority to alter or terminate unsafe activities?
Safety officer
In a CAN report, the letters stand for:
Conditions, Actions, Needs
FIRESCOPE is credited with creating:
The ICS
A 'Mayday' is called when an entry team member needs:
More than 30 seconds to resolve a hot zone issue
On the NFPA 704 diamond, the blue quadrant represents:
Health hazard
On the NFPA 704 diamond, the red quadrant represents:
Flammability
On the NFPA 704 diamond, the yellow quadrant represents:
Reactivity
On the NFPA 704 diamond, the white quadrant represents:
Special hazards
NFPA 704 hazard scale runs from 0 to 4, with 4 meaning:
Severe hazard, the worst rating
A chemical NOT listed in 4H MEDIC ANNA is assumed to be:
Heavier than air
The 'shuns' of evacuation include which of the following:
Persuasion
Which container hauls propane and ammonia, identifiable by rounded ends:
MC-331
Which container is used for cryogenic liquids, double-jacketed and insulated:
MC-338
DOT Class 1 represents:
Explosives
DOT Class 6 represents:
Toxic and infectious substances
DOT Class 8 represents:
Corrosives
A simple asphyxiant works by:
Displacing oxygen without being toxic itself
A chemical asphyxiant works by:
Poisoning the bodyโs ability to use oxygen
Mesothelioma is a cancer caused by long-term exposure to:
Asbestos
The DECIDE modelโs six steps are:
Detect, Estimate, Choose, Identify, Do, Evaluate
Bulk storage containers are classified as such above:
119 gallons
Hazard control zones are established based primarily on:
The chemical and physical properties of the released material