Credentia: Northern California Skill Listing
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No analytics yet
Send a link to your students to track their progress
Step 1
Explains procedure, speaking clearly, slowly and directly, maintaining face-to-face contact whenever possible
Step 2
Before using stethoscope, wipes bell/diaphragm and earpieces of stethoscope with alcohol
Step 3
Client’s arm is positioned with palm up and upper arm is exposed
Step 4
Feels for brachial artery on inner aspect of arm, at bend of elbow
Step 5
Places blood pressure cuff snugly on client’s upper arm, with sensor/arrow over brachial artery site
Step 6
Earpieces of stethoscope are in ears and bell/diaphragm is over brachial artery site
Step 7
Candidate inflates cuff between 160mm Hg to 180 mm Hg. If beat heard immediately upon cuff deflation, completely deflate cuff. Reinflate cuff to no more than 200 mm Hg
Step 8
Deflates cuff slowly and notes the first sound (systolic reading), and last sound (diastolic reading) (If rounding needed, measurements are rounded UP to the nearest 2 mm of mercury)
Step 9
Removes cuff
Step 10
Signaling device is within reach
Step 11
Before recording, washes hands
Step 12 (Bold)
After obtaining reading using BP cuff and stethoscope, records both systolic and diastolic pressures each within plus or minus 8 mm of evaluator’s readings