Temperature and humidity levels in the Sterile Processing department (SPD) need to be monitored and recorded.
at least daily
Survey readiness is the responsibility of.
Survey readiness is everyone's responsibility
Product expiration dates are located on this part of each package:
There is no standard placement for expiration dates
If an equipment malfunction causes harm to a patient, it should be:
Returned to the Biomedical department
Which of the following is considered formal monitoring?
Monitoring the department's temperature and humidity levels
OSHA is responsible for:
Worker safety and the Bloodborne Pathogen
Standard
The human ear is made up of three parts:
a. Inner, middle and external (page
Inner, middle and external
The most common reason for steam sterilization failure
Lack of steam contact with the contents of the load
When working with glutaraldehyde, technicians should always wear ___gloves for protection
Nitrile
Which of the following cannot be used to protect delicate instrument tips during packaging?
Latex tubing
The purpose of using a decontamination battery or hose when cleaning powered surgical instruments is to
Keep fluid from entering the unit
Healthcare-associated infections (HAls) are
Infections that occur on or after day three of a hospitalization
Items that have been used for patient care should be considered:
Contaminated
The term -excise means
Cut Out
Water must be degassed each time an ultrasonic cleaner's tank is changed because excess bubbles from filing
Reduce the energy of the cavitation process
Wrapped trays should not be stacked because
it can cause holes in the wrappers
___monitoring uses a device affixed directly on the employee's clothing.
Personal monitoring
Instrument lubrication should be performed
Following the manufacturer's instructions for use
(IFU)
Immediate use steam sterilization (IUSS) documentation
should include:
Patient ID, sterilizer number and cycle, name of the instrument sterilized
Microbes
Are useful to break down sewage
Temperature and humidity parameters in the SPD can best be established by reviewing which document?
ANSI/ASHRAE/ASHE 170
Monitoring records must be
accurate, legible, and complete
When quality is not emphasized:
conflicts can arise
Case cart systems:
Reduce the amount of space needed for supply storage in user departments
Which of the following requires that preventive. maintenance (PM) standards be established for medical equipment?
The Joint Commission (TIC)
What is a consequence of a healthcare facility not following regulations and standards?
The facility could face legal consequences
The iris is:
The circular opening that controls the amount of light entering the eye
The main difference between IUSS and steam flush pressure pulse (SFPP) processes 1s:
Reduced dry cycle
The use of heat to kill all microorganisms, except spores, is called:
Thermal disinfection
Clean multi-part instruments that have been assembled to test for functionality should
be disassembled and sterilized following manufacturer's Instructions for Use (IFU)
Robotic instruments
May have exposed cables
To minimize their exposure to blooborne pathogens and
other contaminants. SP technicians must wear special
Attire referred to as
Personal Protective Equipment
Which is not a goal of point-of-use treatment:
Transporting items within two hours of the end of the procedure
The suffis -plasty means:
Sargical restoration
Using untreated water:
increases the likelihood of mineral scale deposits
Sterile trays should:
Not be touched until they are properly cooled , lifted not dragged off the sterilizer cart and checked to be sure the external chemical indicators (CIs)have turned the appropriate color
Aeration instructions for a medical device can be found
In the device manufacturers IFU
Scissors with tungsten carbide cutting edges are usually identified by
Black handles
When is point-of-use treatment performed?
Immediately after use
The basic unit of a living organism is a
cell
Know what is dirty, know what is clean, know what is sterile. Keep conditions separate and remedy contamination immediately. These are known as the
the principles of asepsis
Documentation of JUSS eyes should indude
Patient identification and the reason for the IUSS cycle
A true SP quality program utilizes
All SP personnel and a cross section of it customers
The requisition system where items are ordered as needed is called
Requisition system
when SP supports afiliated clinics:
Planning and communication are critical
Which FDA classification is the most stringently regulated and requires a premarket approval (PMA)?
Class III devices
This organ filers the blood to remove amino acids and some harmful toxins:
Liver
Which of the following statements is not true about devices processed by IUSS? The devices:
May be stored for later use
Which of the following are classified as high-level disinfectants?
Glutaraldehyde and ortho-phthalaldehydes(OPA)
The FDA classifies sterilization packaging as a:
Class II Medical Device
Loaned instruments should
be decontaminated before use
Maintaining professional standards of conduct and adapting to changing situations are examples of.
Methods to improve employability
If a user discovers equipment that is in need of repair, they are responsible for notifying the
Biomedical Engineering department
The term ostomy.
is a suffix
Instrument inspection is performed:
After cleaning
The bottom shelf of any sterile storage system should be;
solid and 8-10 inches from the floor
Packaging materials containing cellulose are not compatible with____sterilization:
Hydrogen peroxide
The purpose of a suction stylet is to:
unclog the suction during surgery
Which type of packaging system can be used for IUSS?
A contaminated device that's has been validated for IUSS
Bacteria that cause disease are called:
pathogens
Asepsis is defined as the:
Absence of all microorganisms
External Cls should be found:
On the outsides of packages
The degree or grade of excellence of a product or service is called:
Quality
Capital equipment items are items:
with a high cost price
Which of the following statements is accurate?
Tracking patient care equipment can prevent equipment shortages
Medical device reporting is regulated by the:
FDA (U.S. Food and Drug Administration)
The surgical procedure that removes tissue or displaced bone from the wrist area to release pressure on the median nerve is called:
carpal tunnel repair
How are steam fush pressure pulse (SPy en
classitied?
Dynamic air removal
Thermal disinfection is accomplished using
Heat
Which of the following is an acceptable i per
plastic pouches?
Self-seal. Lousier systems
Information regarding cleaning proceses for ear should be provided by the:
Device manufacturer
Which of the following is an advantage of n invasive surgery (MIS)?
Shorter recovery times
When moving transport carts throughout the healthcare facility, SP technicians must always:
Yield the right of way to patients and visitors
The last word element in a medical term is the
suffix
Instruments should be manually cleaned using a:
To-and-from motion
Trays that overhang shelving
can become contaminated
What is meant by material compatibility?
There should be no charges in the device's functionality
Which solution is known to damage surgical instrumentation?
Betadine
Trems to be disinfected or sterilized at the point of use must be:
Properly cleaned per the manufacturer's IFU
___ is an example of a fungus
athlete's foot
Hand hygiene should be performed
Before starting work m upon entering work,before leaving work
A positive biological indicator (Bl) means:
There is growth in the ampule after incubation
This organization uses unannounced inspections to monitor standards:
Centers for Medicare and Medicaid Services (CMS)
The inventory system that stocks supplies by pre-established stock levels is called a/an:
PAR system
All patient care equipment that is received after use must be considered
and handled as such,
regardless of its appearance.
Contaminated
This agency imposes very strict labeling requirements on manufacturers of chemicals used by the SPD,
FDA
The largest part of the human brain is the:
cerebrum
The coolest area in a steam sterilizer is the:
Drain
How long must alcohol remain in wet contact with an item to achieve a reasonable level of disinfection?
5-10 minutes
Which of the following locations is NOT ideal for sterile storage
Accessible from an outside hallway
Which of the following statements about endoscopes is true
Flexible endoscopes are time-consuming to clean
While items may be dispensed to all areas of a facility, the major focus of the SP personnel is
The OR
This Symbol means (spiked bar graph like)
Date of manufacture
Injuries or disorders of the muscles,nerves, tendons, or joints are called
musculoskeletal disorders
The purpose of a combining vowel is to:
ease pronunciation of a word
Which of the following is not a goal of point-of-use
treatment?
Thoroughly cleaning all instrumentation
Quality control indicaters
Include root cause analysis (RCA)and failure mode and effect analysis(FMEA), are used to determine how well the department is meeting its objectives, should be monitored periodically
Which system provides supplies and instruments for individual surgical procedures?
case cart
The shelving system of choice for the sterile storage area is
closed
Why is it necessary to aerate devices that have undergone EO sterilization?
To remove residual EO gases before instruments and packaging can be handled safely