Temperature and humidity levels in the Sterile Processing department (SPD) need to be monitored and recorded.

at least daily

2
New cards

Survey readiness is the responsibility of.

Survey readiness is everyone's responsibility

3
New cards

Product expiration dates are located on this part of each package:

There is no standard placement for expiration dates

4
New cards

If an equipment malfunction causes harm to a patient, it should be:

Returned to the Biomedical department

5
New cards

Which of the following is considered formal monitoring?

Monitoring the department's temperature and humidity levels

6
New cards

OSHA is responsible for:

Worker safety and the Bloodborne Pathogen

Standard

7
New cards

The human ear is made up of three parts:

a. Inner, middle and external (page

Inner, middle and external

8
New cards

The most common reason for steam sterilization failure

Lack of steam contact with the contents of the load

9
New cards

When working with glutaraldehyde, technicians should always wear ___gloves for protection

Nitrile

10
New cards

Which of the following cannot be used to protect delicate instrument tips during packaging?

Latex tubing

11
New cards

The purpose of using a decontamination battery or hose when cleaning powered surgical instruments is to

Keep fluid from entering the unit

12
New cards

Healthcare-associated infections (HAls) are

Infections that occur on or after day three of a hospitalization

13
New cards

Items that have been used for patient care should be considered:

Contaminated

14
New cards

The term -excise means

Cut Out

15
New cards

Water must be degassed each time an ultrasonic cleaner's tank is changed because excess bubbles from filing

Reduce the energy of the cavitation process

16
New cards

Wrapped trays should not be stacked because

it can cause holes in the wrappers

17
New cards

___monitoring uses a device affixed directly on the employee's clothing.

Personal monitoring

18
New cards

Instrument lubrication should be performed

Following the manufacturer's instructions for use

(IFU)

19
New cards

Immediate use steam sterilization (IUSS) documentation

should include:

Patient ID, sterilizer number and cycle, name of the instrument sterilized

20
New cards

Microbes

Are useful to break down sewage

21
New cards

Temperature and humidity parameters in the SPD can best be established by reviewing which document?

ANSI/ASHRAE/ASHE 170

22
New cards

Monitoring records must be

accurate, legible, and complete

23
New cards

When quality is not emphasized:

conflicts can arise

24
New cards

Case cart systems:

Reduce the amount of space needed for supply storage in user departments

25
New cards

Which of the following requires that preventive. maintenance (PM) standards be established for medical equipment?

The Joint Commission (TIC)

26
New cards

What is a consequence of a healthcare facility not following regulations and standards?

The facility could face legal consequences

27
New cards

The iris is:

The circular opening that controls the amount of light entering the eye

28
New cards

The main difference between IUSS and steam flush pressure pulse (SFPP) processes 1s:

Reduced dry cycle

29
New cards

The use of heat to kill all microorganisms, except spores, is called:

Thermal disinfection

30
New cards

Clean multi-part instruments that have been assembled to test for functionality should

be disassembled and sterilized following manufacturer's Instructions for Use (IFU)

31
New cards

Robotic instruments

May have exposed cables

32
New cards

To minimize their exposure to blooborne pathogens and

other contaminants. SP technicians must wear special

Attire referred to as

Personal Protective Equipment

33
New cards

Which is not a goal of point-of-use treatment:

Transporting items within two hours of the end of the procedure

34
New cards

The suffis -plasty means:

Sargical restoration

35
New cards

Using untreated water:

increases the likelihood of mineral scale deposits

36
New cards

Sterile trays should:

Not be touched until they are properly cooled , lifted not dragged off the sterilizer cart and checked to be sure the external chemical indicators (CIs)have turned the appropriate color

37
New cards

Aeration instructions for a medical device can be found

In the device manufacturers IFU

38
New cards

Scissors with tungsten carbide cutting edges are usually identified by

Black handles

39
New cards

When is point-of-use treatment performed?

Immediately after use

40
New cards

The basic unit of a living organism is a

cell

41
New cards

Know what is dirty, know what is clean, know what is sterile. Keep conditions separate and remedy contamination immediately. These are known as the

the principles of asepsis

42
New cards

Documentation of JUSS eyes should indude

Patient identification and the reason for the IUSS cycle

43
New cards

A true SP quality program utilizes

All SP personnel and a cross section of it customers

44
New cards

The requisition system where items are ordered as needed is called

Requisition system

45
New cards

when SP supports afiliated clinics:

Planning and communication are critical

46
New cards

Which FDA classification is the most stringently regulated and requires a premarket approval (PMA)?

Class III devices

47
New cards

This organ filers the blood to remove amino acids and some harmful toxins:

Liver

48
New cards

Which of the following statements is not true about devices processed by IUSS? The devices:

May be stored for later use

49
New cards

Which of the following are classified as high-level disinfectants?

Glutaraldehyde and ortho-phthalaldehydes(OPA)

50
New cards

The FDA classifies sterilization packaging as a:

Class II Medical Device

51
New cards

Loaned instruments should

be decontaminated before use

52
New cards

Maintaining professional standards of conduct and adapting to changing situations are examples of.

Methods to improve employability

53
New cards

If a user discovers equipment that is in need of repair, they are responsible for notifying the

Biomedical Engineering department

54
New cards

The term ostomy.

is a suffix

55
New cards

Instrument inspection is performed:

After cleaning

56
New cards

The bottom shelf of any sterile storage system should be;

solid and 8-10 inches from the floor

57
New cards

Packaging materials containing cellulose are not compatible with____sterilization:

Hydrogen peroxide

58
New cards

The purpose of a suction stylet is to:

unclog the suction during surgery

59
New cards

Which type of packaging system can be used for IUSS?

A contaminated device that's has been validated for IUSS

60
New cards

Bacteria that cause disease are called:

pathogens

61
New cards

Asepsis is defined as the:

Absence of all microorganisms

62
New cards

External Cls should be found:

On the outsides of packages

63
New cards

The degree or grade of excellence of a product or service is called:

Quality

64
New cards

Capital equipment items are items:

with a high cost price

65
New cards

Which of the following statements is accurate?

Tracking patient care equipment can prevent equipment shortages

66
New cards

Medical device reporting is regulated by the:

FDA (U.S. Food and Drug Administration)

67
New cards

The surgical procedure that removes tissue or displaced bone from the wrist area to release pressure on the median nerve is called:

carpal tunnel repair

68
New cards

How are steam fush pressure pulse (SPy en

classitied?

Dynamic air removal

69
New cards

Thermal disinfection is accomplished using

Heat

70
New cards

Which of the following is an acceptable i per

plastic pouches?

Self-seal. Lousier systems

71
New cards

Information regarding cleaning proceses for ear should be provided by the:

Device manufacturer

72
New cards

Which of the following is an advantage of n invasive surgery (MIS)?

Shorter recovery times

73
New cards

When moving transport carts throughout the healthcare facility, SP technicians must always:

Yield the right of way to patients and visitors

74
New cards

The last word element in a medical term is the

suffix

75
New cards

Instruments should be manually cleaned using a:

To-and-from motion

76
New cards

Trays that overhang shelving

can become contaminated

77
New cards

What is meant by material compatibility?

There should be no charges in the device's functionality

78
New cards

Which solution is known to damage surgical instrumentation?

Betadine

79
New cards

Trems to be disinfected or sterilized at the point of use must be:

Properly cleaned per the manufacturer's IFU

80
New cards

___ is an example of a fungus

athlete's foot

81
New cards

Hand hygiene should be performed

Before starting work m upon entering work,before leaving work

82
New cards

A positive biological indicator (Bl) means:

There is growth in the ampule after incubation

83
New cards

This organization uses unannounced inspections to monitor standards:

Centers for Medicare and Medicaid Services (CMS)

84
New cards

The inventory system that stocks supplies by pre-established stock levels is called a/an:

PAR system

85
New cards

All patient care equipment that is received after use must be considered

and handled as such,

regardless of its appearance.

Contaminated

86
New cards

This agency imposes very strict labeling requirements on manufacturers of chemicals used by the SPD,

FDA

87
New cards

The largest part of the human brain is the:

cerebrum

88
New cards

The coolest area in a steam sterilizer is the:

Drain

89
New cards

How long must alcohol remain in wet contact with an item to achieve a reasonable level of disinfection?

5-10 minutes

90
New cards

Which of the following locations is NOT ideal for sterile storage

Accessible from an outside hallway

91
New cards

Which of the following statements about endoscopes is true

Flexible endoscopes are time-consuming to clean

92
New cards

While items may be dispensed to all areas of a facility, the major focus of the SP personnel is

The OR

93
New cards

This Symbol means (spiked bar graph like)

Date of manufacture

94
New cards

Injuries or disorders of the muscles,nerves, tendons, or joints are called

musculoskeletal disorders

95
New cards

The purpose of a combining vowel is to:

ease pronunciation of a word

96
New cards

Which of the following is not a goal of point-of-use

treatment?

Thoroughly cleaning all instrumentation

97
New cards

Quality control indicaters

Include root cause analysis (RCA)and failure mode and effect analysis(FMEA), are used to determine how well the department is meeting its objectives, should be monitored periodically

98
New cards

Which system provides supplies and instruments for individual surgical procedures?

case cart

99
New cards

The shelving system of choice for the sterile storage area is

closed

100
New cards

Why is it necessary to aerate devices that have undergone EO sterilization?

To remove residual EO gases before instruments and packaging can be handled safely