What is automatic exposure control (AEC)
If enabled, it eliminates the need for the radiographer to manually select mAs
_____ is very important for proper use of AECs
Patient positioning
Can AECS be used on all projections?
NO
Do all Imaging systems include AEC circuits
NO. Portable X-ray units typically don’t
The term “——“ originates from early AEC systems
Phototimer
Phototimers (orignaited from early AEC systems) used _____ screens that converted X-ray energy into emitted light photons
This light was then absorbed by a _____ tube that converted its energy into electrical current
Fluorescent
Photomultiplier
Modern AEC systems use a ___ ___ chamber
Gas ionization

What are these
AEC units

AEC unit modern systems: 1
Ionization chamber

AEC modern unit: 2
IR
Gas ionization chamber
what happens upon exposure?
X-rays ionize air molecules within the ionization chamber, which ionizes the air molecules and frees electrons
Gas ionization chamber
step 2
Freed electrons are attracted to a positively charged anode wire where they form an electrical current that can be measured
Gas ionization chamber
step 3
The greater the measurement of electrical current, the greater the amount of X-ray exposure the ionization chamber has received
Gas ionization chamber
step 4
When a predetermined amount of exposure has been received and detected by the AEC circuit, the exposure is automatically terminated
AEC intensity control is also called what
Master density or density control
What does the AEC intensity control do
Increases or decreases the present sensitivity of the AEC/ density by specific percentages, such that the resulting exposure time is extended or shortened
What is a common format for AEC intensity control (Or master density or density control)
-3, -2, -1, 0, +1, +2, and +3
AEC intensity control common format
what does N or 0 mean
Normal exposure
AEC intensity control
Genuinely each setting represents a ____% Additive increase or decrease
25%
-1 = 25% decrease in relative exposure
-2 = 50% decrease in relative exposure
+1 = 25% increase in relative exposure
+2 = 50% increase in relative exposure
When adjusting the AEC intensity control, the _____ of exposure will be adjusted (Which impacts the ____ Used)
Length, mAs
The AEC intensity control should only need to be used _____ - The exception rather than the rule
Infrequently
Minimum response time
the AEC is not _____
Instantaneous
Minimum response time (MRT):
Defined as the minimum amount of time it takes for the electric current to detect and react radiation
Minimum response time (MRT) Is typically measured in the _____ Range
Thousandths (0.001)
What is a potential problem for the minimum response time (MRT)?
This can be a problem if the mAs Is very small
(If a very small mAs (mA x time) Calls for a time smaller than the minimum response time the exposure is incapable of occurring that quickly)
What is the solution to the potential problem for the minimum response time (MRT)?
The technologies could maintain the same mAs But use a small smaller mA And a large larger time to ensure the exposure is longer than the minimum response time
MRT practice:
assume a room has a MRT of 0.005 seconds
Suppose the ideal technique for a pediatric trust projection is 65KVP and 0.8 mAs. If the 300 mA Setting is used, In over exposure of almost twice too much would be delivered. Why?