What sample type is collected in a red top?

Serum

2
New cards

What sample type is collected in a green top?

Plasma

3
New cards

What chemical assays must be put on ice?

Ammonia

Blood gas

Lactic acid

4
New cards

What is the additive and anticoagulant in grey top?

Additive: Sodium fluoride

Anticoagulant: Potassium oxalate

5
New cards

What test is done using a grey tube?

Glucose tolerance test (GTT)

Fasting blood sugar

Blood alcohol

Lactic acid

6
New cards

Why must EDTA tubes not be used for chemistry tests? What measurements are falsely increased and decreased?

EDTA contains sodium and potassium which will lead to falsely elevated results, and it chelates calcium ions which will falsely decrease calcium results

7
New cards

What measurements are affected by running a hemolyzed sample? (Hint: KLAMP)

Elevated Potassium, LD, ALD, ACP, Magnesium, Phosphate, and hemoglobin

8
New cards

What causes hemolysis during collection?

Small needle diameter, tourniquet bound for too long, rough pull on syringe, prolonged testing, improper temperature during storage and transport