1. Which of the following statements is true regarding interpretation of SPRCA results?

a. Grading reactions is based on a l-to-4 grading scale where 4+ is a strong positive.

b. A tight button of cells on the bottom of the well would be interpreted as a positive reaction.

c. Hemagglutination assay results are interpreted the same as SPRCA results.

d. An evenly distributed layer of cells on the well surface is a negative reaction.

2
New cards

C

Indicator cells used in SPRCA are:

a. IgM-coated red cells useful in determining the presence of ABO antibodies

b. cells used to agglutinate IgG antibodies to form a pellet in the well after centrifugation

c. IgG-coated red cells that cross-link with IgG antibodies attached to the well

d. check cells that are added to negative reactions to validate the washing step

3
New cards

C

3. In the gel test, a button of cells at the bottom of the well is

a:

a. 4+ positive reaction

c. negative reaction

b. 1+ positive reaction

d. invalid reaction

4
New cards

B

4. The gel test and SPRCA share which of the following advantages over the antiglobulin tube testing method?

a. both use prediluted cells, saving reagent expense

b. endpoints are stable and reviewable for at least 2 days

c. centrifugation is not required for either system

d. a washing step is not required for either system

5
New cards

D

5. Which method is used in the automated Immucor system for ABO and D phenotype?

a. solid phase red cell adherence assay (SPRCA)

b. enzyme-linked immunosorbent assay (ELISA)

c. reverse-passive hemagglutination (RPHA)

d. hemagglutination in a microwell

6
New cards

D

6. False-negative reactions can occur in both gel test and SPRCA for which of the following errors?

a. failing to centrifuge

c. incubation time was too short

b. not mixing reagent red cells sufficiently

d. all of the above

7
New cards

C

7. Mixed-field reactions were observed in the 1D-MTS Gel Test for ABO and D phenotype using the ORTHO Pro Vue. What is the most likely cause of this observation?

a. improper pipetting technique

b. the use of contaminated reagents

c. transfusion of group O cells to an A or B patient

d. centrifugation error

8
New cards

B

8. After centrifugation using the ID-MTS anti-IgG gel cards, a layer of agglutinated cells was observed at the top of two of the three screening cell microtubes. What should be done next?

a. repeat the test

b. proceed to an antibody identification panel

c. perform a DAT to determine if the patient has an autoantibody

d. verify the negative reaction with check cells

9
New cards

A

9. The MTS Monoclonal A/B/D Grouping Gel Card is used for:

a. typing A, B, and D antigen

c. typing Rh system antigens

b. antiglobulin crossmatches

d. direct antiglobulin test

10
New cards

D

10. The Capture-R select microwell strips are used for:

a. direct antiglobulin test

b. antiglobulin testing of selected panel cells

c. weak D test

d. all of the above

11
New cards

A

11. Bar-code technology is used in automated instruments to ensure positive sample identity.

a. True

b. False

12
New cards

A

12. LIS interfaces link the automated test system with a laboratory information system for reporting results.

a. True

b. False

13
New cards

A

13. Automation should make it easier to do things the right way and more difficult to do the wrong things.

a. True

b. False

14
New cards

B

14. When selecting an automation partner , a laboratory does not need to determine its requirements in terms of customer support, training, and service.

a. True

b. False

15
New cards

A

15. Rapid turnaround times for selected samples and the ability to accommodate large volume batch testing contribute to overall operational efficiency.

a. True

b. False

16
New cards

A

16. Vendors of automation for the transfusion service require prior approval from the FDA.

a. True

b. False

17
New cards

A

17. Vendor assessment, base technology, and instrument assessment are important considerations in the selection of an automated system.

a. True

b. False

18
New cards

A

18. Automation can be purchased for gel technology and SPRCAs.

a. True

b. False

19
New cards

B

19. Because of the sensitivity of the SPRCAs and gel assays, the immediate-spin crossmatch for detecting ABO compatibility is no longer necessary.

a. True

b. False