SEPTIC TANK

0.0(0)
studied byStudied by 0 people
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
Card Sorting

1/26

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

27 Terms

1
New cards

2

MINIMUM COMPARTMENTS OF SEPTIC TANK (INLET AND OUTLET)

2
New cards

0.6-1.8 m

LIQUID DEPTH OF SEPTIC TANK

3
New cards

2/3

MINIMUM INLET OF FIRST COMPARTMENT

4
New cards

2 CU.M

MIN. CAPACITY OF 1ST COMPARTMENT

5
New cards

0.9 m

MIN. WIDTH OF 1ST COMPARTMENT

6
New cards

1.5 m

MIN. LENGTH OF 1ST COMPARTMENT

7
New cards

1/3

MAX. OUTLET 2ND COMPARTMENT

8
New cards

1 CU.M

MIN. CAPACITY OF 2ND COMPARTMENT

9
New cards

1.5 m

MIN. LENGTH OF THE SECONDARY COMPARTMENT IF THE SEPTIC TANK HAS OVER 6 CU.M CAPACITY

10
New cards

2

MIN. NUMBER OF MANHOLES IN SEPTIC TANK

11
New cards

508 mm

MIN. DIMENSION OF MANHOLE

12
New cards

1

__ MANHOLE IS OVER THE INLET AND MANHOLE OVER THE OUTLET

13
New cards

3.7 M

ADD 1 MORE MANHOLE ABOVE THE BAFFLE WALL IF THE FIRST COMPARTMENT EXCEEDS __ M IN LENGTH

14
New cards

50.8 MM

VERTICAL CLEARANCE OF INVERT OF THE INLET PIPE ABOVE THE INVERT OF THE OUTLET PIPE

15
New cards

50.88 MM

VERTICAL CLEARANCE OF THE COVER OF THE SEPTIC TANK ABOVE THE BACK VENT OPENINGS

16
New cards

101.6 MM

EXTENSION OF INLET AND OUTLET PIPE OR BAFFLE PARTITIONS BETWEEN COMPARTMENTS ABOVE THE WATER SURFACE

17
New cards

104.6 MM

MIN. VERTICAL LEG OF THE INLET AND OUTLET FITTING

18
New cards

104.6 MM

MIN. INVERTED FITTING INSTALLED IN THE INLET COMPARTMENT SIDE OF THE BAFFLE

19
New cards

106.6 MM

MIN. HORIZONTAL DIMENSION OF BAFFLE TYPE FITTING WHEN MEASURED AT THE INLET AND OUTLET PIPE INVERTS

20
New cards

228.6 MM

EXTENSION OF SIDEWALLS ABOVE THE LIQUID DEPTH

21
New cards

304.8 MM

EXTENSION OF INLET AND OUTLET PIPE OR BAFFLE BELOW THE WATER SURFACE

22
New cards

14.4 KPA

MIN. EARTH LOAD SUPPORT OF SEPTIC TANK COVER WHEN THE MAX. COVERAGE DOES NOT EXCEED 9 m

23
New cards

101.6 MM

MIN. BITUMINOUS COATING EXTENSION BELOW THE WATER LINE FOR CONCRETE SEPTIC TANKS AND SHALL COVER ALL OF THE INTERNAL AREAS ABOVE THAT POINT

24
New cards

GAUGE 12 US (2.8 MM)

MIN. WALL THICKNESS OF ANY STEEL SEPTIC TANK

25
New cards

BITUMINOUS COATING

STEEL SEPTIC TANK MUST BE PROTECTED EXTERNALLY AND INTERNALLY BY _____

26
New cards

PROHIBITED

WOODEN SEPTIC TANKS AND BAFFLES ARE _____

27
New cards

EFFLUENT DISPOSAL

ALL FLOW TEST SHALL BE PERFORMED THROUGH THE SYSTEM TO THE POINT OF ______