1/24
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
What mechanism does a powered instrument use to fracture calculus deposits from the tooth surface?
Option A
Force of water spray exiting the tip
Option B
Tiny bubbles that collapse, producing shock waves
Option C
Electricity
Option D
Rapid energy vibrations of the instrument tip
Option D
Rapid energy vibrations of the instrument tip
The rule of thumb when adjusting the power setting of the ultrasonic unit is to set it _____ than you think necessary.
Option A
faster
Option B
lower
Option C
slower
Option D
higher
Option B
lower
The water flowing through a powered instrument tip forms tiny bubbles that collapse, producing shock waves that destroy bacteria by tearing the bacterial cell walls. This mechanism of action is termed _____.
Option A
cavitation
Option B
acoustic turbulence
Option C
deplaquing
Option D
aerosol production
Option A
cavitation
Strengths of using powered instrumentation include all of the following except:
Option A
Provides access to furcation areas
Option B
Irrigation of pocket washes toxic products and bacteria
Option C
Penetrates deeper into periodontal pockets
Option D
Extends instrumentation time
Option D
Extends instrumentation time
Which insert tip design would you select to remove large-sized calculus supragingival deposits from the proximal surfaces of posterior teeth?
Option A
Beavertail
Option B
Triple bend
Option C
Slim-diameter straight
Option D
Standard-diameter universal
Option B
Triple bend
The water that exits near the tip of an ultrasonic instrument tip _____.
Option A
cools the instrument tip and washes bacteria from the pocket
Option B
cools the instrument tip
Option C
removes calculus deposits
Option D
warms the instrument handpiece
Option A
cools the instrument tip and washes bacteria from the pocket
On a powered instrument tip, the power to remove calculus is concentrated in the last _____ of the length of the tip.
Option A
10 mm
Option B
6 mm
Option C
2 mm
Option D
1 mm
Option C
2 mm
Which of the following powered instrument tip designs should be used on posterior tooth surfaces located more than 4 mm below the CEJ?
Option A
Standard-diameter triple bend tip
Option B
Standard-diameter universal tip
Option C
Slim-diameter curved tips
Option D
Slim-diameter straight tip
Option C
Slim-diameter curved tips
On a powered instrument tip, which of the surfaces is recommended for adaptation to the tooth surface with all sonic, piezoelectric, and magnetostrictive ultrasonic instruments?
Option A
Back of the tip (the convex surface)
Option B
Face of the tip (the concave surface)
Option C
Lateral surfaces of the tip
Option D
Point of the tip
Option C
Lateral surfaces of the tip
Which insert tip design would you select to remove supragingival and subgingival calculus deposits throughout the mouth?
Option A
Slim-diameter straight
Option B
Triple bend
Option C
Beavertail
Option D
Standard-diameter universal
Option D
Standard-diameter universal
Which insert tip design would you select to remove large calculus ledges on the lingual of mandibular anterior teeth?
Option A
Standard-diameter universal
Option B
Triple bend
Option C
Beaver tail
Option D
Slim-diameter straight
Option C
Beaver tail
The vertical or “probe position” for the powered tip is used _____________.
Option A
with a powered periodontal probe
Option B
when deplaquing deep periodontal pockets
Option C
when removing supragingival calculus only
Option D
for anterior teeth only
Option B
when deplaquing deep periodontal pockets
Powered tips should be inspected for wear and discarded when they have _____ of wear.
Option A
3 mm
Option B
4 mm
Option C
2 mm
Option D
1 mm
Option C
2 mm
On a powered instrument tip, which of the surfaces produces the greatest amount of energy vibrations?
Option A
Point of the tip
Option B
Lateral surfaces of the tip
Option C
Face of the tip (the concave surface)
Option D
Back of the tip (the convex surface)
Option A
Point of the tip
How many times a powered instrument tip vibrates in 1 second is known as the _____.
Option A
power
Option B
stroke
Option C
frequency
Option D
adjustment
Option C
frequency
The transverse tip orientation is recommended for _______________.
Option A
removing moderate subgingival calculus in deep pockets
Option B
removing calculus in furcations
Option C
none of the above
Option D
removing calculus above or slightly below the gingival margin
Option D
removing calculus above or slightly below the gingival margin
When removing calculus deposits with a powered instrument, what type of lateral pressure is recommended?
Option A
Light lateral pressure
Option B
Moderate lateral pressure
Option C
Firm, scraping pressure
Option D
Either moderate or firm pressure
Option A
Light lateral pressure
The rule of thumb when adjusting the water flow on the ultrasonic unit is to _____ than you think necessary.
Option A
use less
Option B
make sure it is cooler
Option C
use more
Option D
make sure it is warmer
Option C
use more
How far the tip of a powered instrument tip moves during one cycle is known as the _____.
Option A
stroke
Option B
power
Option C
frequency
Option D
adjustment
Option A
stroke
On a powered instrument tip, which of the surfaces produces the least (lowest) amount of energy vibrations?
Option A
Lateral surfaces of the tip
Option B
Face of the tip (the concave surface)
Option C
Back of the tip (the convex surface)
Option D
Point of the tip
Option A
Lateral surfaces of the tip
For calculus removal, a powered instrument is used in a series of tapping motions. For subgingival deplaquing, the lateral surface of a powered instrument is moved in a series of sweeping motions.
Option A
The first statement is false; the second statement is true.
Option B
Both statements are false.
Option C
The first statement is true; the second statement is false.
Option D
Both statements are true.
Option D
Both statements are true.
Higher power settings for powered instrumentation deliver a shorter stroke. To maximize patient comfort, the power setting should rarely be placed above low.
Option A
The first statement is true; the second statement is false.
Option B
The first statement is false; the second statement is true.
Option C
Both statements are false.
Option D
Both statements are true.
Option C
Both statements are false.
On a powered instrument tip, which of the surfaces should never be adapted to the tooth surface because it could damage the tooth surface?
Option A
Face of the tip (the concave surface)
Option B
Lateral surfaces of the tip
Option C
Point of the tip
Option D
Back of the tip (the convex surface)
Option C
Point of the tip
The lowest effective power setting should be used during powered instrumentation. Two criteria that should be considered to determine the power setting for powered instrumentation are the size of the calculus deposit and the diameter of the powered instrument tip.
Option A
The first statement is false; the second statement is true.
Option B
Both statements are true.
Option C
The first statement is true; the second statement is false.
Option D
Both statements are false.
Option B
Both statements are true.
One effective way to reduce the number of airborne organisms in the aerosols produced by a powered instrument is _____.
Option A
asking the patient to wear a mask that has a high bacterial filtration efficiency
Option B
changing the clinician mask every 20 minutes during powered instrumentation
Option C
asking the patient to use an antimicrobial mouthrinse before treatment
Option D
adjusting the water flow to a minimum flow rate until the instrument handpiece feels warm during use
Option C
asking the patient to use an antimicrobial mouthrinse before treatment