Accessible (barrier-free) toilet min. clearance
60” along the rear wall
56” along side wall
Accessible (barrier-free) shower min. clear floor space required for side transfer
36” x 48”
Accesible (barrier-free) work surface min. and max. height
min: 28”
max: 34”
Accessible lavatory min. depth
17”
Barrier-free lavatory mirror max. mounting height AFF
40” AFF
Mounting height and minimum length of horizontal grab bars at the sidewall of an accessible toilet
mounting height: 33”-36”
length: 42” min
Mounting height and minimum height of vertical grab bars at the sidewall of an accessible toilet
mounting height: 39”-41”
length: 18” min
Accessible urinal mounting height and max. dimension of top rim
mounting height: 44”
top of rim: 17”
Mounting heights between ____ cannnot protrude more than 4” from the wall into a corridor
27”-80”
Minimum clear door width
32”
Toe-kick height for ADA clearance
9”
Push/Pull door clearance
push: 12” min
pull: 18” min
ADA reach height for an upper cabinet at a non-barrier free work surface
44” max. (non-barrier free work surface is 20”-25” max.)
ADA reach height for an upper cabinet at a barrier-free work surface
48” max. (barrier-free work surface is 20” max.)
ADA minimum reach height on a wall
15” min
Accessible stair handrail diameter
1 1/4” - 2”
Max stair riser height
7”
Min. clear space under an accessible counter
27” H x 30” W x 17” D for knee clearance
Min. clear width of a ramp
36”
Min. landing length for a ramp (top and bottom of a ramp too)
60”
1:10 ramp slope is permitted if the max rise does not exceed __
6”
Ramps with risers greater than __ or lengths greater than __ must have handrails
risers greater than 6”
lengths greater than 72”
Mounting height of a handrail above a ramp surface
34”-38”
Floor clearance space for a sign
18” x 18”
Directional and Informational signage letter heights
5/8” - 3” (uppercase or lowercase letters)
Permanent room signage letter heights
5/8” - 2” (uppercase letters only)
Signage mounting height
48”-60”
Commercial grade cabinet panels have a thickness of