8 Terms

1
New cards

Q: What is the factory specification range for the JDF cabinet temperature?

A: 35°F to 41°F

2
New cards

Q: How do you adjust the drink strength if the sugar refractometer reading is incorrect?

A: PC board dials: clockwise (stronger) or counterclockwise (weaker)

3
New cards

Q: How long should you wait for the JDF cabinet temperature to settle before checking it?

A: 10 minutes

4
New cards

Q: What needs to be done with the O-rings before reinstalling the dispense nozzles?

A: Apply food-grade lubricant

5
New cards

Q: When testing the flow rate and finish drink temperature, how long should you dispense?

A: 3 seconds

6
New cards

Q: If the dispensed volume during the three-second test is less than 3 ounces, what should you do?

A: Service call for repair

7
New cards

Q: Where should the water bath level be maintained on the JDF?

A: At the sight tube holding clip

8
New cards

Q: What must you ensure about the thermometer when checking the product cabinet temperature?

A: Touching air only, no surfaces