1
New cards

PSO + ISA = ______

Maximum Allowable Construction Area (MACA)

2
New cards

The required open space left between the outermost face of the building/structure and the property lines

Yard

3
New cards

Setback on two sides shall be optional on what residential occupancy?

R-2, R-3, R-4

4
New cards

Roofed Carports are not part of the Total Open Space within Lot (TOSL)

True

5
New cards

Habitable rooms provided with artificial ventilation shall have ceiling heights not less than ______

2.40m

6
New cards

For buildings of more than one (1) storey, the minimum ceiling height of the first storey shall be _________

2.70m

7
New cards

The minimum ceiling height of a naturally ventilated habitable room is

2.70m

8
New cards

Mezzanine floors shall have a clear ceiling height not less than ______ above and below it

1.80m

9
New cards

Minimum size of Rooms for Human Habitations

6.00 sqm with at least dimension of 2.00m

10
New cards

Minimum kitchen floor area

3.00 sqm

11
New cards

Minimum size of bath and toilet

1.20 sqm with at least dimension of 900mm

12
New cards

Eaves, canopies, awnings over required windows shall not be less than _____ from the side and rear property lines

750mm

13
New cards

The window area of a toilet and bathrooms shall be at least

1/20 of floor area

14
New cards

Minimum vent shall have dimension of

600mm

15
New cards

Minimum air space per person in a habitable room

14m³

16
New cards

Lots bounded on two or more sides by the property line of the subdivision or by public open spaces ; accessible only through one side of the lot

End Lot

17
New cards

Referred to as a regular lot

Inside Lot

18
New cards

Minimum provisions for lighting and ventilation at basement levels: A primary or main natural light and ventilation shaft with a clear distance of at least _____ meters shall be located at the center of the building and traverse the entire combined height of the building above and below grade

3.00m