1/7
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
Tzanck preparation
imprint the lesion
clean lesion with saline sponge
take another imprint
debride and take another imprint
If scab is present, imprint the bottom of that scab
Imprint the exposed tissue
syringe and needle for needle biopsy
21-25g needle
3-20 ml syringe
softer tissue needs smaller syringe and needle, as large needles will collect tissue cores leading to blood contamination and poor yield of free cells
Wedge Film
use sample collected by fine needle biopsy
Transfer the sample to a clean slide, near the frosted edge
use a second slide at an angle, back the slide edge into the sample
allow sample the spread along the edge
use the slide to push the sample the full length of the slide
Is basically done like a blood smear
Fine needle - aspiration technique
stabilize the mass
insert needle into the mass and draw back to create negative pressure
Redirect the needle several times, do not exit the mass and maintain negative pressure
remove the needle from the mass
remove the syringe from the needle
fill syringe with air and reattach needle
gently force the sample from the needle onto clean slide
air dry, fix ans stain
Fine needle - non-aspiration technique
Done the same as aspiration technique but done with just a needle or a needle and syrine wirth the plunger removed from the syringe
stabilize the mass
insert needle into the mass
Redirect the needle several times, do not exit the mass and maintain negative pressure
remove the needle from the mass
remove the syringe from the needle
fill syringe with air and reattach needle
gently force the sample from the needle onto clean slide
air dry, fix ans stain
compression smear
Transfer the sample to a clean slide, near the frosted edge
add another slide perpendicular (the should be criss crossed)
in a smooth single motion pull the top slide evenly across the bottom
air dry, fix, and stain the top slide
viewed under 40x
Modified compression smear
use sample collected by fine needle biopsy
transfer sample to clean slide near frosted edge and toward middle of the slide
add another slide perpendicular (the should be criss crossed)
in a smooth single motion twist the two slides in opposite directions (create an X shape)
life the top slide straight up
air dry, fix, and stain the top slide
viewed under 40x
Line smear
use sample collected by fine needle biopsy
Transfer sample to a clean slide near the frosted edge
use a second slide at an angle and back the edge of the slide into the drop of the sample
allow sample to spread along the edge of the slide
Use the second slide to push the sample across the slide and stop abuptly before getting to slide end abruptly
pick second slide straight up
air dry, stain, and fix