All of the following are considered advantages of digital imaging except?

Digital imaging has a narrow exposure latitude

2
New cards

Quantization is:

The process of assigning numerical data to the signal

3
New cards

A string of 8 bits is called aa:

Byte

4
New cards

A matrix with a greater number of pixels displays:

Greater spatial resolution

5
New cards

The number of shades of gray a system can digitize is called a:

Bit depth

6
New cards

A 16-bit depth system can display more shades of gray than a 4-bit depth system.

True

7
New cards

What is the measure of spatial resolution?

line pairs per mm

8
New cards

Which of the following describes the pixel pitch?

Measured from the center of one pixel to the center of the adjacent pixel and includes gaps between them

9
New cards

The ability of a material to respond to excitation and give off light is called:

scintillation

10
New cards

Which of the following describes conversion efficiency?

The percentage of energy absorbed by the receptor that is converted to usable output

11
New cards

Which of the following decreases the exposure required to produce an image, which decreases patient dose?

High DQE

12
New cards

Higher fill factor of a DEL equals:

Higher spatial resolution

13
New cards

Information patterns that don't add to the diagnostic image are called:

Noise

14
New cards

Higher ___ indicates that the receptor is more efficient in converting the input signal.

DQE

15
New cards

A picture element is also called a:

Pixel

16
New cards

The ability to distinguish small objects in a radiographic image is termed:

Spatial resolution

17
New cards

Pixel density and matrix size are fixed characteristics of a digital image receptor and cannot be altered by the technologist.

True

18
New cards

Absorption efficiency multiplied by conversion efficiency equals:

DQE

19
New cards

The element(s) used in flat-panel detectors as a scintillation material is:

Cesium iodide or Gadolinium oxysulfide

20
New cards

What term refers to the receptors' ability to respond to different exposure levels?

Dynamic Range

21
New cards

What term refers to the range of underexposure or overexposure that can occur and still produce an acceptable image?

Exposure latitude

22
New cards

A digital receptor can produce an image that appears acceptable but which was produced at ___% underexposure to ___% overexposure?

50, 100

23
New cards

After the image receptor collects the attenuated beam, the captured image is called:

Latent image

24
New cards

The process of converting the analog signal to a digital signal that happens in the ADC consists of which two steps?

Sampling and quantization

25
New cards

A series of boxes laid out in rows and columns that gives form to the image is called:

Matrix

26
New cards

Which of these statements is true regarding pixel size?

The smaller the pixel, the greater the spatial resolution

27
New cards

The number of pixels in a given area is called:

Pixel density

28
New cards

The type of flat-panel detector that converts energy from the X-ray beam directly into electrons is called?

Direct

29
New cards

In direct DR imaging, which of these materials converts light photons into electrons that migrate to thin-film-transistors (TFTs) and produce an electrical signal?

Amorphous silicon

30
New cards

In direct DR imaging, which of these materials is used to convert X-ray photons into electrons, which are collected by a TFT and produce an electronic signal?

Amorphous selenium

31
New cards

Which of these devices collects electrons emitted from either the amorphous silicon or amorphous selenium?

TFT

32
New cards

Which of these statements are true?

The lower the fill factor, the lower the spatial resolution

33
New cards

When purchasing X-ray equipment, which two of these should be considered by the department manager?

1. Dynamic range of the system

2. SNR of the system

34
New cards

Which of the following will produce an image with the highest resolution?

Narrow pixel pitch

35
New cards

Quantum noise limits the ability to see:

detail

36
New cards

What element traps and stores electrons that make up the latent image in F-centers?

europium activators

37
New cards

Which of these converts the analog signal to a digital signal?

ADC

38
New cards

Which of these is a graphic representation of the exposure values from the IR?

histogram

39
New cards

Which of these is described as a vertical line on the histogram that represents the frequency for each signal?

y-axis

40
New cards

Which of these is described as a horizontal line on the histogram that represents signal intensity that is proportional to X-ray exposure?

x-axis

41
New cards

If the captured values do not match the standardized histogram, the captured values are adjusted to match the standardized ones to display an acceptable image. This process is called:

automatic rescaling

42
New cards

The final step in digital image processing is to set the gray scale or contrast for the image. This process is accomplished by:

look-up table

43
New cards

The potential to gradually increase patient exposure over time because there are no visual cues for overexposure is called:

dose creep

44
New cards

Using the correct technical factors, collimation, and SID for the part allows the LUT to work correctly.

True

45
New cards

The ___ changes the numerical values of the pixels to the expected contrast levels for the anatomical part.

look-up table

46
New cards

Which of these is used to determine the approximate level of exposure to the IR since visual cues are usually not available?

exposure indicator

47
New cards

Which of these organizations has made a concerted effort to standardize exposure indicators?

American Association of Physicists in Medicine

48
New cards

The exposure indicator can have a direct or inverse relationship with receptor exposure.

true

49
New cards

The standard exposure indicator that can be used with all digital systems is called:

deviation index

50
New cards

Which of these devices calculates the dose by determining the entrance dose in centigray multiplied by the exposure field size for the image?

dose area product meter

51
New cards

As the number of pixels per square centimeter in the monitor increases, the monitor is able to display images at a higher resolution.

true

52
New cards

To display the gray scale in a radiograph, the monitor must be able to demonstrate at least ___ shades of gray.

256

53
New cards

The minimal requirement for a monitor's spatial resolution must be ___ when viewing a 14"x17" image.

2.5 lines per mm

54
New cards

What occurs when the electron beam intensity fluctuates as the beam scans back and forth across the back of the phosphor in the monitor?

temporal noise

55
New cards

The contrast resolution of a monitor is described as:

difference between the maximum and minimum luminance of the display

56
New cards

The minimal level of luminance is called:

the black level

57
New cards

Which of these terms refers to the number of times an image drawn on the screen refreshes?

refresh rate

58
New cards

A screen may display thumbnail images of the exams. This is called:

tiling

59
New cards

ACR standards require gray-scale monitors used for radiographic interpretation to provide a minimum of:

171 candela per square meter

60
New cards

Electronic markers applied during post-processing are not legal markers; markers must be placed during image acquisition.

true

61
New cards

The process whereby 2 images can be obtained, and then the software application melds the two images together to create one contiguous image is called:

stitching

62
New cards

Adjusting the window width is used to:

adjust the contrast on the monitor

63
New cards

Which of these describes a workstation software function that allows a black mask to be placed over bright areas on the screen:

shuttering

64
New cards

Specific numerical ranges assigned to pixels that contain the diagnostically useful information are referred to as:

values of interest

65
New cards

Which of these will provide the proper gray-scale, regardless of variation in kVp or mAs, resulting in consistent images?

look-up table

66
New cards

What is described as the distance from the center of one pixel to the center of the adjacent pixel on a radiographic monitor?

pixel pitch

67
New cards

The alternative term for noise is saturation.

false

68
New cards

Which of these can be the cause of grid cut-off?

improper SID

69
New cards

When an image shows signs of noise, what must be done to correct the image?

the image must be repeated with a higher mAs

70
New cards

___ is described as overexposure to the point where the dynamic range of the system can no longer accurately display the image data.

saturation

71
New cards

The purpose of the ___ is to reduce the amount of scatter radiaation reaching the image receptor.

grid

72
New cards

If a technologist fails to properly align the CR with the grid, what effect can result?

grid cut-off

73
New cards

What effect can occur when two exposures are made on one IR?

exposure field recognition error

74
New cards

The predominant cause of image blur is:

motion

75
New cards

Misrepresentation of the true shape of an object is referred to as:

shape distortion

76
New cards

The ___ is developed by the medical imaging department and is designed to produce quality images at acceptable doses.

target exposure index

77
New cards

Plate-based artifacts generally appear as ___ on the image.

white

78
New cards

The plate-based artifacts generally run along an entire plate axis and appear on nearly all images.

false

79
New cards

A hair stuck to one of the optics blocks the signal in that area and can cause an artifact with a ___ pattern.

wig-wag

80
New cards

Which of these is not true regarding artifacts in flat-panel DELs?

can be mitigated by cleaning the flat-panel detector array

81
New cards

An important standard that facilitates communication in medical imaging and establishes the software standards for exchanging electronic information in health care is called:

HL-7

82
New cards

The universally accepted standard for exchanging medical images among networked medical devices that was developed by the American College of Radiology is referred to as:

DICOM

83
New cards

The computer-based storage, retrieval, and viewing system for digital imaging examinations is called:

can be referred to as PACS or MIMPS

84
New cards

The ___ helps to distinguish one patient's data from another, reducing the chance for errors when choosing patient from worklist.

all of these are correct

2 multiple choice options

85
New cards

Diagnostic workstations used by the radiologist require high-resolution monitors that must have a display resolution of:

at least 2000 x 2000

86
New cards

A computer network limited to a relatively small area is referred to as a:

LAN

87
New cards

A network that utilizes a centralized computer that controls the operation of the network is called:

client/ server-based network

88
New cards

The device that connects multiple network segments is called:

network switch

89
New cards

The junction between two or more networks that allows data packets among the networks to be transported and buffered is called a:

router

90
New cards

What security device controls traffic between a single computer and a computer network with no security, or between a computer network in a trusted environment and a computer network in a less secure environment?

firewall

91
New cards

An image was created that showed a line that runs the entire length of the plate and parallel to the direction the plate travels through the reader. This artifact is contributed to:

a dirty light guide

92
New cards

What is the first thing that the technologist should do to correct a flat-panel DEL detector artifact?

recalculate the detector

93
New cards

A ___ network consists of 3 or more comuters that share resources and information.

network

94
New cards

Which of the following is a way that images in PACS can be accessed:

PACS images can be accessed in any of these options

2 multiple choice options

95
New cards

The maximum number of computer that cen be connected in a LAN is:

10

96
New cards

The difference between a bridge and a router is that a bridge uses the media access control to control data transfer, and the router uses an IP address.

true