1/32
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
1. Water
2. Movement and circulation
3. Storm drainage
4. Solid and liquid waste disposal
5. Park/playground
6. Power
Basic needs of human settlements, enumerated in descending order as follows:
with reasonable distance from the project site / shall be provided for by the developer.
The prioritized basic needs cited earlier shall preferably be available ____
no fixed ratio
There shall be ____ between the saleable portion and non-saleable portion of a subdivision project.
1 hectare or above
Area allocated for parks and playgrounds shall be mandatory for projects ____ and shall be strategically located within the subdivision project.
100 square meters
In no case shall an area allocated for parks and playgrounds be less than
72 sqm
Minimum Lot Area - Single - Economic
64 sqm
Minimum Lot Area - Single - Socialized
48 sqm
Minimum Lot Area - Duplex - Socialized
54 sqm
Minimum Lot Area - Duplex - Economic
36 sqm
Minimum Lot Area - Row houses - Economic
28 sqm
Minimum Lot Area - Row houses - Socialized
22 sqm
The minimum floor area requirement for single-family dwelling shall be _____ for economic housing
18 sqm
The minimum floor area requirement for single-family dwelling shall be _____ for socialized housing
1.5, 1.5, 2
The minimum setback of dwelling unit both for economic and socialized housing project shall be as follows: (Front, Side, Rear)
150 liters per capita per day.
Minimum quantity requirement shall be (water)
concrete lined canal with load bearing cover.
The minimum drainage system for economic and socialized housing shall be
300 milimeters
Minimum drainage pipe shall be
50%, 20%, 10%, 5%
Percentage of Open Space

2.0 meters shall be provided
Where ceilings are not provided, a minimum headroom clearance of
10 occupants
A minimum of one entrance/exit shall be provided where the number of occupants is not more than
0.60 meter
Stairways shall have a minimum clear width of
150 millimeters or 6 inches thick
The firewall shall be of masonry construction, at least
duplex/single-attached units and at every unit for row houses.
A firewall shall be provided for

4.0 meters.
In general, the minimum distance between 2 buildings in which the taller buildings does not exceed 2 storeys shall be

10 meters.
The minimum distance between buildings with more than 4 storeys
one (1) parking slot per eight (8) living units. (1:8)
For multi-family dwellings and condominiums, the parking requirement shall be
the minimum floor area of a living unit in multi-family dwellings shall be
6 storeys and beyond.
Provision of elevators shall be required for buildings