1
New cards

1. Water

2. Movement and circulation

3. Storm drainage

4. Solid and liquid waste disposal

5. Park/playground

6. Power

Basic needs of human settlements, enumerated in descending order as follows:

2
New cards

with reasonable distance from the project site / shall be provided for by the developer.

The prioritized basic needs cited earlier shall preferably be available ____

3
New cards

no fixed ratio

There shall be ____ between the saleable portion and non-saleable portion of a subdivision project.

4
New cards

1 hectare or above

Area allocated for parks and playgrounds shall be mandatory for projects ____ and shall be strategically located within the subdivision project.

5
New cards

100 square meters

In no case shall an area allocated for parks and playgrounds be less than

6
New cards

72 sqm

Minimum Lot Area - Single - Economic

7
New cards

64 sqm

Minimum Lot Area - Single - Socialized

8
New cards

48 sqm

Minimum Lot Area - Duplex - Socialized

9
New cards

54 sqm

Minimum Lot Area - Duplex - Economic

10
New cards

36 sqm

Minimum Lot Area - Row houses - Economic

11
New cards

28 sqm

Minimum Lot Area - Row houses - Socialized

12
New cards

22 sqm

The minimum floor area requirement for single-family dwelling shall be _____ for economic housing

13
New cards

18 sqm

The minimum floor area requirement for single-family dwelling shall be _____ for socialized housing

14
New cards

1.5, 1.5, 2

The minimum setback of dwelling unit both for economic and socialized housing project shall be as follows: (Front, Side, Rear)

15
New cards

150 liters per capita per day.

Minimum quantity requirement shall be (water)

16
New cards

concrete lined canal with load bearing cover.

The minimum drainage system for economic and socialized housing shall be

17
New cards

300 milimeters

Minimum drainage pipe shall be

18
New cards

50%, 20%, 10%, 5%

Percentage of Open Space

<p>Percentage of Open Space</p>
19
New cards

2.0 meters shall be provided

Where ceilings are not provided, a minimum headroom clearance of

20
New cards

10 occupants

A minimum of one entrance/exit shall be provided where the number of occupants is not more than

21
New cards

0.60 meter

Stairways shall have a minimum clear width of

22
New cards

150 millimeters or 6 inches thick

The firewall shall be of masonry construction, at least

23
New cards

duplex/single-attached units and at every unit for row houses.

A firewall shall be provided for

24
New cards
<p>4.0 meters.</p>

4.0 meters.

In general, the minimum distance between 2 buildings in which the taller buildings does not exceed 2 storeys shall be

25
New cards
<p>10 meters. </p>

10 meters.

The minimum distance between buildings with more than 4 storeys

26
New cards

one (1) parking slot per eight (8) living units. (1:8)

For multi-family dwellings and condominiums, the parking requirement shall be

27
New cards

the minimum floor area of a living unit in multi-family dwellings shall be

28
New cards

6 storeys and beyond.

Provision of elevators shall be required for buildings

29
New cards
30
New cards
31
New cards
32
New cards
33
New cards