- traditional indigenous family dwelling
- projects covered by BP220
what is excluded and is not required to use NBCP as a requirement to construct?
addition
any new construction increasing the height and/or floor area
alteration
changes in materials, partitioning, openings, or utilities that do not increase height or floor area
conversion
a change in the use of occupancy of a building
renovation
any physical change made to increase value, quality, or improve aesthetics
- public buildings (government)
- traditional indigenous family dwelling (less than 15k, native materials, single family)
who are exempted from building permit fees
null and void
what happens to the building permit if you lack ancillary permits
false, mandatory
true or false:
a location clearance from the city/ municipal zoning administration is optional
building permit will be void
what happens if after 1 yr of issuance of building permit, there is still no construction?
120 days
how long can a work be suspended or paused for the building permit not be voided?
false, subject to most restrictive requirement
true or false:
when a building has mixed occupancy, the whole building is subject to whichever has high percentage of space.
occupancy
defines how a specific building within that zone is used
zoning
dictates where land can be used, density, development controls
R1
Low-density residential zone, characterized mainly by single-family, single detached dwellings with the usual community ancillary uses on a neighborhood scale, such as executive subdivisions and relatively exclusive residential communities which are not subdivisions
R2 BASIC
Single-attached or duplex building/structure of from one (1) storeyup to three (3) storeysin height and with each unit for separate use as single-family dwellings
R2 MAX
Low-rise multi-level building/structure of from three (3) up to five (5) storeysin height and for use as multiple family dwellings
R3 BASIC
Row house building/structure of from one (1) storey up to three (3) storeys in height and with each unit for separate use as single-family dwellings
R3 MAX
Medium-rise multi-level building/ structure of from six (6) up to twelve (12) storeys in height and for use as multiple family dwellings
R4
A medium to high-density residential use or occupancy, characterized mainly as a low-rise townhouse building/ structure for exclusive use as multiple family dwellings
R5
A very high-density residential use or occupancy, characterized mainly as a medium-rise or high-rise condominium building/structure for exclusive use as multiple family dwelling
PSO (Percentage of Site Occupancy)
portion of the lot that can be covered by the building footprint
TOSL (total open space of the lot)
the remaining portion of the lot not covered by the PSO, dedicated to yards, courts, and setback
10% of rooms floor area
according to NBCP for rooms without artificial ventilation, the total free area of windows must be at least _____________
2.7m
minimum floor to ceiling height for naturally ventilated rooms
occupant load
the maximum number of people a space is designed to safely hold
1.80
what is the unit area in sqm per occupant in a classroom use
9.30
what is the unit area in sqm per occupant in a office use
0.65
what is the unit area in sqm per occupant in a auditorium use
2
how many exit is required for occupant load less than 500
3
how many exit is required for occupant load 500-999
4
how many exit is required for occupant load 1000 or more
not less than 1/5 of the perimeter of the area served
if 2 exits are required they must be placed a distance apart of
60m
with sprinkler system what is the maximum travel distance to exits
45m
without sprinkler system what is the maximum travel distance to exits
1.1m
what is the minimum stairway dimension according to NBCP For occupant load less than 50
200MM, 250MM
maximum rise and minimum rise of stairs as per NBCP
3m
minimum clear height of arcades above the sidewalk, vertoical clearance of canopies/ marquees, and balconies
2.4m
minimum height of fences
1.2m
when sidewalk is closed a temporary walkway of not less than _______ wide must be provided
development controls
A set of inter-acting regulationsconcerning the physical utilization of a lot and likewise governing the planning/design of spaces and/or the use or occupancy of a building/structure to be introduced (or already existing) on a lot
development controls
help determine in detail the Development Potential
and/or the Carrying Capacityof all lots and/or of proposed developments on lots.
It can be enforced on any building, regardless of when it was built.
what is the meaning of this: fire code is retrospective
architect in charge of construction
who signs for occupancy permit
Fire Safety Inspection Certificate
No
Certificate of Occupancy, Business Permit or Permit to Operate
shall be issued without securing a
means of egress
a continuous and unobstructed route of exit from one point in a building, structure, or facility to a public way.
Access, Exit, Exit discharge
what are the 3 distinct parts of means of egress
exit
That portion of means of egress that is separated from all other spaces of a building or structure by construction, location, or equipment as required to provide a protected way of travel to the exit discharge.
access
That portion of means of egress that leads to an exit.
exit discharge
That portion of a means of egress between the termination of an exit and a public way.
3m
Public Way. A street, alley, or other similar parcel of land open to the outside air, deeded to the public, with a clear width and height of at least ___________
self-closing fire resistive door
Any opening in the separation wall/construction shall be protected by an approved
1hr
for protective enclosures of exit of 3 storeys what is the fire resistance duration
2hrs
for protective enclosures of exit of 4 or more storeys what is the fire resistance duration
915mm
The width of any means of egress shall not be less than
the number of fixed seats installed
The occupant load of an area having fixed seats shall be determined by
not less than two (2) exits by separate ways of travel
When exits are not immediately accessible from an open floor area, continuous passageways, aisles, or corridors leading directly to every exit shall be maintained and shall be arranged to provide access for each occupant to
not less than 1/2 of the length of the maximum overall diagonal dimension of the building
When two (2) exits or exit access doors are required, they shall be located at a
distance from one another
false, single exit
true or false:
interlocking or scissor stairs are considered 2 exits for new buildings
6m
Means of egress shall be so arranged that there are no dead-end pockets, hallways, corridors, passage ways or courts, whose depth exceeds
2m
fire exit The minimum headroom shall not be less than
side-hinged or pivoted-swinging type
Any door in a means of egress shall be of the
1/2 of corridor
When the door is swinging open, it cannot block more than
178mm
When the door is completely open, it must not stick into the corridor by more than:
not less than the width of the door
he landing shall have a width...
710mm
Door openings in means of egress shall not be less than
1.22m
No single door in a doorway shall exceed a width of
915mm
What is the minimum clear width of a stair serving fewer than 50 occupants, excluding projections below handrail height?
1120mm
What is the minimum clear width of a stair serving less than 2000 occupants, excluding projections below handrail height?
1420mm
What is the minimum clear width of a stair serving more than 2000 occupants, excluding projections below handrail height?
applies only to events, construction, or changes that occur after the law takes effect
what is the meaning of this:bp344 is prospective
10%
how many percent of the total units for government housing shall be accessible
1.1m x 0.8m
wheelchair size
1.8m
wheelchair turning diameter
0.4m
lowest point a person on a wheelchair can can reach
1.2m
highest point a person on a wheelchair can can reach
1.2m
Minimum clear width for a PWD ramp
there is dropped sidewalk, curb ramp, an elevator, or other mechanical device
Changes in level shall require a ramp except when
100mm
ramp raised edge on both sides minimum height
tactile warning strips
Ramps shall be provided with __________________ at the head, foot, and landings.
300 mm
handrails must extend __________ past the start and end of the ramp
1.8m
minimum landing length and length of level area before and after the ramp
10.50m
Maximum total length allowed for a ramp with 1:15 slope
700mm
Maximum rise allowed for a ramp with 1:15 slope
15m
for a 1:20 slope at what length do you need to add landing (landing interval for 1:20 slope)
10m
for a 1:15 slope at what length do you need to add landing (landing interval for 1:15 slope)
railing across the full width of its lower end
Any ramp with a rise greater than 200 mm and leads down towards an area where vehicular trafficis possible, shall have a
170mm
Handrails
shall be required for accessible ramps for changes in grade higher than
900mm
upper handrail height for accessible ramp and stairs
700mm
lower handrail height for accessible ramp and stairs
150mm
for accessible stairs what is the maximum uniform riser
300mm
for accessible stairs what is the minimum uniform treads
1.5m
accessible staircase shall have a clear width of
1.5m
Sidewalks, walkways, and pathways shall have a minimum width of
1.8m
Where space is required for two (2) wheelchairs to pass, the minimum width shall be
2.2m
Sidewalk/walkway headroom shall not be less than
900mm/leaf
according to bp344 All doors shall have a minimum clear width of
1.5m
Corridors shall have minimum clear width of
12 m, 1.8 m × 1.8 m
for Every _________ along a long corridor, you must provide a ___________ turnabout space
2
Highly populated or high occupancy buildings shall be able to accommodate at least _________ wheelchair users per elevator at the same time
30m
accessible elevators should be how far from the entrance