FLSA Time Records Retention
FLSA time cards and schedules must be retained for a minimum of 2 years.
FLSA Payroll Records Retention
FLSA payroll records must be retained for a minimum of 3 years.
Building Permit Expiration Threshold
Permits typically expire if work is not started within 180 days or if work is suspended or abandoned for 180 days.
Commercial Stairway Riser and Tread Dimensions
Maximum riser height of 7 inches and minimum tread depth of 11 inches.
Residential Stairway Riser and Tread Dimensions
Maximum riser height of 743 inches and minimum tread depth of 10 inches.
Handrail Height Requirement
Handrails must be placed between 34 inches and 38 inches measured vertically from the leading edge of the stair tread.
Exit Sign Emergency Power Duration
Emergency exit signs must be powered by an emergency circuit providing illumination for at least 90 minutes upon power loss.
ASTM C143
The standard governing the slump test for concrete using a cone that is 12 inches high.
Type M Mortar
High-strength mortar used for heavy structural loads and below-grade applications.
Type S Mortar
Medium-high strength mortar used for normal structural loads and exterior load-bearing walls.
Type N Mortar
Medium-strength mortar used for general interior above-grade applications.
Type O Mortar
Low-strength mortar used for historic restoration and non-load-bearing interior applications.
Concrete Initial Curing Requirement
Requires maintaining moisture and temperature for a minimum of 7 days during initial curing.
Dry Lumber Classification
Dimension lumber classified as 'dry' when its moisture content is 19% or less.
Low-Slope Roof Drainage Minimum
Built-up or single-ply low-slope roofs require a minimum slope toward points of drainage of 41 inch per foot.
Garage and Dwelling Separation Wall
Requires 21-inch gypsum board (or 85-inch Type X gypsum board if habitable rooms are above the garage) with no hourly fire-resistance rating required.
Slotted Deflection Track
A steel top runner track used on non-bearing interior steel-framed walls to allow vertical structural deflection from floor/roof movement without taking on axial loads.
Fire Alarm Control Panel (FACP) Enclosure Rating
Requires a baseline minimum 1-hour fire-resistance rating (or 2-hour depending on elevator or smoke control infrastructure supported).
Cripple Wall Height Threshold (IRC R602.9.1)
If a cripple wall exceeds 48 inches (4 feet) in height, it must be framed with studs the next size larger or engineered as a full story.
Untreated Plywood Siding Ground Clearance
Requires a minimum clear distance of 6 inches from the earth (8 inches if touching concrete or masonry foundations).
Accessible Route
A continuous, unobstructed path connecting all accessible elements and spaces of a building or facility.
Hot Weather Concrete Pour Risk
High temperature, high wind, and low relative humidity trigger plastic shrinkage cracking and reduce compressive strength due to rapid surface evaporation.
Concrete Over-Agitation in Transit Truck
Grinds coarse aggregates, increases mix temperature, lowers slump, decreases air entrainment, and reduces overall concrete compressive strength.
Roof Soffit Property Line Proximity
Projections cannot extend closer than 2 feet to an interior property line and must be 1-hour fire-resistance rated or heavy timber if between 2 feet and 5 feet.
Unexposed Foundation Concrete Strength
A baseline minimum compressive strength of 2500 PSI for interior footings, basement walls, or slab-on-grade foundations completely protected from weathering.
Clothes Washer Standpipe Rating
Rated as a 2 DFU (Drainage Fixture Unit) load on the drainage system and requires a minimum standpipe/trap diameter of 2 inches.
Maximum Bored Hole in Load-Bearing Wood Stud
Strictly capped at 25% of stud depth (121 inches maximum diameter for a nominal 2x6 stud).
Foundation Anchor Bolt Rules
Must be embedded at least 7 inches into concrete, spaced maximum 6 feet apart, and located within 12 inches of the end of each sill plate section.
Area of Refuge
A fire-resistive and smoke-protected location within a building where persons unable to use stairways can shelter temporarily during emergency evacuation.
Area of Refuge Wheelchair Space Rule
Requires a designated clear space measuring at least 30 inches×48 inches for every 200 occupants served.
Ventilation Clearance for Roof Insulation
A minimum 1-inch clear space maintained between insulation material and roof sheathing at soffit or eave vents.
Fireblocking
Solid materials installed inside wall cavities and floor-ceiling spaces at maximum intervals of 10 feet horizontally and at floor/ceiling levels vertically to eliminate hidden air paths.
Draftstopping
Thinner materials installed in large concealed spaces to divide horizontal cavities into compartments not exceeding 1000 sq ft in residential or 3000 sq ft in commercial.
Interlayment
An 18-inch wide layer of asphalt-saturated felt woven between every course (layer) of wood shakes.
Type A Construction Classification
Refers to Protected Construction sub-classification of Types I through V building materials.
Floor Joist Notching Limits (Outer Thirds)
Maximum notch depth cannot exceed 61 of the joist depth and is prohibited in the middle third of the joist span.
Floor Joist End Notch Limit
Maximum notch depth cannot exceed 41 of the joist depth at support points.
Floor Joist Bored Hole Limit
Diameter cannot exceed 31 of the joist depth and must be located at least 2 inches from edges, notches, or other holes.
Joist Bearing Length Requirements
Minimum 121 inches on continuous wood top plates or steel beams, and minimum 3 inches directly on masonry or concrete.
Sloped Glazing Definition
Glass or glazing installed at a slope of more than 15 degrees from the vertical plane.
Habitable Room Ventilation Requirement
Openable window area must equal at least 4% of the room's total floor area (with glazing total area at least 8% for natural light).
Emergency Escape Window (EERO) Area Specs
Minimum net clear opening of 5.7 sq ft (5.0 sq ft at grade level) with a maximum sill height of 44 inches above the floor.
Stairway Headroom Clearance
Minimum clear vertical headroom height of 80 inches (6 feet 8 inches).
Horizontal Wood Bevel Siding Overlap
Requires each course of siding to overlap the board beneath it by a minimum of 1 inch.
Minimum Thickness for Plywood
Roof Sheathing (IRC Table R803.2.1(1) / IBC Table 2304.8(1))
7/16-inch. These panels will carry a Span Rating stamp of 24/16 from the manufacturer (meaning 24 inches on a roof, or 16 inches on a floor)
Minimum Thickness for Plywood Subfloors (IRC Table R503.2.1(1) / IBC Table 2304.8(2))
For 16-Inch Joist Spacing: Minimum 5/8-inch (or 19/32-inch nominal).
For 24-Inch Joist Spacing: Minimum ¾-inch (or 23/32-inch nominal).
A contractor is building a two-story home and needs to select sawn lumber for the first-floor load-bearing wall studs. What is the minimum grade allowed?
No. 2. Stud is for vertical wall columns and Utulity is max roof and ceiling, never a floor. Section R602.3.1
Can you use No. 3 lumber for a floor girder?
No. Minimum would be zero
Openings in the partitions
shall be protected by self-closing doors with automatic latches.
Floor joists must have a minimum of 1 ½ inches of bearing where they rest on wood wall plates or steel beams UNLESS
the ends of the joists are supported on a 1-inch by 4-inch (1x4) ribbon strip that is notched into the wall studs, and the joist is securely nailed directly to the face of the adjacent stud
The absolute maximum distance allowed between the washer trap weir and the vent fitting
8 feet
Markets (Group M - Mercantile) and Banks (Group B - Business) that cross the 49-person threshold
Two separate exits/exit doors are required, the main exit doors must swing outward in the direction of exit travel and requiring doors to be equipped with panic hardware or fire exit hardware (push bars)
If a room is calculated to hold 50 or more people
it is legally classified as an Assembly space, and it must have a minimum of two separate exits