Digital Radiography Flat-Panel Systems (Ch. 22)

0.0(0)
studied byStudied by 0 people
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
Card Sorting

1/31

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

32 Terms

1
New cards

Flat panel digital radiography (DR) eliminates having a ______, therefore reducing the steps for the radiographer

Cassette

2
New cards

DR systems use either a:

  1. Direct detector with a photoconductor (one type)

  2. Indirect detector with a scintillator (three types)

3
New cards

Direct detectors convert incoming x-ray photons to an ___________

Electronic digital signal

4
New cards

A direct detector uses ________ being the active layer (photoconductor) and a _________

Amorphous selenium (a-Se), thin film transistor (TFT)

5
New cards

_____ are used in flat panel technology for both amorphous silicon and selenium plates

TFT’s

6
New cards

TFT’s containing _________ are the last step of the x-ray conversion which collects the electric charge to produce an electronic readout

Detector elements (DELs)

7
New cards

TFT’s are set up like an array or matrix with pixel-size ______

DELs

8
New cards

_______ sense/collect and store image signal information and contain a switch

DELs

9
New cards

When DELs are filled with information, they become a ______

Dexel

10
New cards

Each pixel contains a “____________”, while other electronics which are not sensitive to charge

Sensing area

11
New cards

Fill factor

Refers to the sensing area compared to the non-sensing area (expressed as a percentage)

12
New cards

The fill factor has a _______ relationship with spatial resolution and contrast resolution

Direct

13
New cards

The ______ the fill factor, the ______ the spatial resolution and contrast resolution, compared to detectors with a lower fill factor

Higher

14
New cards

______ is a semiconductor with excellent x-ray photon detection ability

a-Se

15
New cards

The process of direct conversion contains three steps:

  1. High voltage is applied to the top surface of a-Se

  2. Ionization from the exposure frees the atoms from a-Se for the collection by electrodes at the bottom of an a-Se layer

  3. Charges are collected by the TFT and are then read line by line to the computer for processing

16
New cards

Indirect detectors _______ directly convert x-rays into an electric signal

Cannot

17
New cards

Indirect detectors all use a ________

Scintillator

18
New cards

The three types of indirect detectors are:

  1. Amorphous silicon (a-SI:H) with a flat panel TFT detector

  2. Charged coupled device (CCD)

  3. Complementary metal oxide semiconductor (CMOS)

19
New cards

All indirect detector systems need the ________ to change x-ray photons to light

Scintillator

20
New cards

All indirect detector systems must have a _______ or _______ to change light to an electronic signal

Photocathode or photodetector

21
New cards

The process of the indirect conversion when using amorphous silicon with a TFT contains three steps:

  1. The scintillator emits light isotropically

  2. Amorphous silicon (a-Si:H) acts as a light detector (photodiode)

  3. Flat panel TFT detector read line by line to computer for processing

22
New cards

When the scintillator emits light isotropically is will be made of either two things:

  1. Cesium iodide (Csl)

  2. Rare-earth intensifying screen composed of gadolinium oxysulfide (Gd2O2S)

23
New cards

Amorphous silicon will need a relatively _____ layer to provide adequate sensitivity to photons and must be paired with a scintillator

Thicker

24
New cards

Amorphous silicon capture fluorescent light, and then converts that light into ____________ which are then gathered by the TFT within DELs

Electrical charges

25
New cards

The three disadvantages of using CMOS chips with the indirect conversion is:

  1. Less stable over time

  2. Yield lower quality images

  3. More susceptible to noise

26
New cards

The DR images are processed with an algorithm selected that will use exposure field recognition, histogram analysis, and applying the ________

LUT

27
New cards

Flat field detectors can have bad ______, which creates artifacts

DELs

28
New cards

One major difference with DR processing (compared to CR) is that only exposed ______ are read and use for image data

DELs

29
New cards

DR panels range from $_____ to $_______

$30,000 to $80,000

30
New cards

The routine use of DR panels requires cleansing to prevent the spread of ________

Infection

31
New cards

Some DR panels can handle _____ lbs of direct weight, but only around 500 lbs if the DR panel is bending

800

32
New cards

Detector bag

Protects the DR panel from blood urine, discharge, scrub fluid, saline, etc