TUBE
It specifies OD and wall thickness.
SCHEDULE
It specifies wall thickness.
FUSION WELDING
How do you connect PPR?
SDR
It is the specific ration of the average specified outside diameter to the minimum wall thickness for outside controlled diameter plastic pipe.
SCHEDULE 40
It refers to STD (Standard) of a pipe.
ABLUTION
It is a ceremonial act of washing parts of the body of sacred containers.
WATER POTABILITY
The discharge from clinical sinks and conveyed to the building drain is defined as a waste pipe.
building sewer that conveys both sewage and storm water
The combination building sewer is a ____.
SOLDERED JOINT
A joint obtained by joining of metal parts with metallic mixtures or alloy that melt at a temperature up to and including 840°F is a ____.
CONDUCTOR
A pipe inside a building that conveys storm water from the roof to a storm drain is called a/an ____.
BOILER BLOWOFF
An outlet on a boiler to permit emptying and discharging of sediment is called a/an ____.
AIR CHAMBER
A pressure surge-absorbing device operating through the compressibility of air is called _____.
BOTTOM
When a backflow prevention device does not bear a critical level marking, the part of the device that shall constitute the critical level is the _____.
EVERY OTHER STOREY
Cast iron soil pipe, installed vertically shall be supported at its base and at _____.
45°
All trenches deeper than the footing of any building or structure and paralleling the same shall be at least ____ therefrom.
10 ft
Threaded pipe (IPS) 3/4” except for gas piping, installed horizontally shall be supported at approximately ____ intervals.
A FIRM BED
Piping in the ground shall be laid on ____.
AUTOMATIC IN OPERATION
Tanks flushing more than one urinals shall be ____.
PROHIBITED
Trough urinals shall be ____.
AIR GAP
It is the clear vertical distance between the spout of a faucet or other outlet of a supply pipe and the flood level of a receptacle.
TO COMPLY WITH ACCESSIBILITY STANDARDS
The curb or threshold of a shower compartment may be eliminated ___.
30”
Water closets set side by side shall be no closer than _____ center to center.
ONE URINAL
No manually controlled flushometer valves shall be used to flush more than _____.
FLUSH TANKS
Automatically controlled flushometer valves may be substituted for automatic ____.
SCHEDULE 80
The minimum wall thickness for threaded plastic pipe shall be _____.
CARRIER FITTING
Wall-mounted water closets shall be securely bolted to a ____.
1000
When brazing, the alloys shall have a melting temperature of at least ____ degrees Farenheit.
BRASS
Screws or bolts for securing floor mounted fixtures shall be _____.
UTILITY SPACE or ACCESS PANEL
Fixtures having concealed slip joint connections shall be provided with a _____.
TAPE
It is acceptable for use on male threads only if screwed pipe joint.
FLARING TOOL
Soft copper water tubing shall be expanded with ____.
180 mm
The P-trap top should be no higher than ____ below floor level.
LEVELING ROD
A graduated rod used in measuring the vertical distance between a point on the ground.
GAGE PRESSURE + ATMOSPHERIC PRESSURE
Absolute pressure is ____.
23 m
Standard length of a fire hose.
DOWNSPOUT
The vertical portion of a rainwater conductor.
BLIND FLANGE
A flange that closes the end of a pipe.
BUILDING DRAIN
Part of the lowest horizontal piping of a drainage system which receives the discharge from soil, waste, and other drainage pipes inside the walls of a building.
BUILDING SUBDRAIN
Portion of an underground system, which cannot drain by gravity into the building sewer.
CAP
A fitting, screwed or caulked over the end of a pipe for closing the pipe end.
CATCH BASIN
A receptacle in which liquids are retained for a sufficient period of time to allow settleable material to deposit.
ACIDIC
pH = 0 stands for ____.
RELIEF VENT
Primary function is to provide air circulation of air between drainage and vent systems.
LIQUID WASTE
Is the discharge from any fixture, appliance or appurtenance in connection with a plumbing system which does not receive fecal matter.
VENT SYSTEM
Is a pipe or pipes installed to provide a flow or circulation of air within the plumbing system to protect trap seals siphoning and back pressure.
ALKALINE
pH = 14 means ___.
102 mm
The minimum pipe size for dry standpipe is ___.
125 mm
The minimum diameter of a dry standpipe requiring a 3-way Siamese connection is ____.
152 mm
The minimum diameter of a dry standpipe requiring a 4-way Siamese connection.
FIRM BED
Each receptor built directly on the ground shall have, except:
smooth
impervious
durable surfaces
firm bed
1 HOUR
The ABS stack can be tested ____ after the last joint is made.
DRUM TRAP
The name was derived from its size being large in diameter and also classified as a water seal device.
ZINC
Copper has several alloys such as brass that are used as a plumbing material. What is the principal alloy found in brass?
LETTER C
Air test procedures, except:
a. attaching an air compressor testing apparatus to any suitable opening
b. having uniform gauge pressure of 5 psi at least 15 mins
c. having uniform gauge pressure of 35.4 kPa at least 15 mins.
d. the inlet and outlet of the system shall be closed and sufficient balance a column of 254 mmHg in height
MACK
What is the name of the washer that seals the bottom of a lavatory bowl?
END-TO-CENTER
What is the correct and most accurate way to measure out lengths of pipe?
same gpm
How do you connect pump in series?
120°F
According to the IPC, above what temperature can you consider as hot water?
COMPRESSION TYPE
What type of faucet is now most often used on plumbing fixtures?
VENT
Straight tees are used in what section of the DWV system?
BIDET
Women’s urinal fixture.
PIPE CHASE
Best location to put soil pipes?
INDIVIDUAL HOUSE PIPES IN CONNECTION WITH METER
Level 3 types of water service refers to ___.
GAS PIPE
Black steel pipe with galvanized malleable fitting is ideal for ____.
COUPLING
A pipe fitting to joint two straight lengths of pipes.
SCHEDULE
The quality of Galvanized Iron pipe are rated by _____.
LOCAL VENT
A pipe or shaft to convey foul air from a plumbing fixture or a room to the outer air.
PENDENT
Kind of sprinkler heads that basically used with ceiling that has temperature of 155°F.
DRAINAGE, WASTE, VENT
DWV in the drainage installation of plumbing system stands for ____.
SPIGOT
The end of a cast iron pipe that fits into a bell or hub.
HYDROGEN SULFIDE
What gas in the septic tank is colorless and has an irritating odor?
SERIES 1000
What type of PVC pipe is used on sanitary drainage system?
OFFSET
A combination of elbows or bends which brings one section of the pipe out of line but into a line parallel with the original section.
SLIP JOINT
It is a joint primarily on the fixture side of a trap made tight with a rubber plastic type washer and slip nut.
2.4 m
Fixtures outlet shall not be connected to the horizontal drainage pipe within ____ of any vertical to horizontal change of direction of a stack containing suds producing fixtures.
CLOSING PIPE ENDS WITH FEMALE THREAD
What is the purpose of a plug?
25 mm
Drainage airgap shall not be less than ____ between the plumbing fixture and the flood level rim.
SACRARIUM
Waste from church altar services that must be disposed off directly to the ground.
2 3/4 inches
Which is not a commercial size of a galvanized steel pipe?
WATER CLOSETS
Cleanouts may be omitted from horizontal drainage pipes less than 1.5 m on length, unless serving _____.
1/2 of the cross-sectional area
For horizontal drain pipe, what is the ideal airspace?
TO PREVENT ADDITIONAL STRESS ON THE JOINTS
Reason why supports are installed next to a fitting?
DURHAM SYSTEM
Term used to describe soil or waste system where all piping are of threaded pipe.
GOOSENECK
Return bend of small-sized pipe, one end of which is about 30 cm long and the other is about 7.5 cm long. It is commonly used as a faucet for a pantry sink. Also, the term means the flexible tubing connection between a service pipe and water main.
COUNTERSUNK
A kind of cleanout plug that will be installed in case where raised heads may cause hazards to passing personnel or vehicles.
AT EVERY FIXTURE WITH INTEGRAL TRAP
At what locations are plumbing traps required?
NO; INDIRECT WASTE
Are wastes from a drinking fountain needed to be trapped?
AIR GAP
The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe, conveying waste to the flood level rim of the receptor.
SUPPORT
Devices for holding and securing pipes and fixtures to walls, ceiling, floors, or structural members.
BACKWATER VALVE
Device that prevents the reversal flow in the drainage system.
GALVANIZED STEEL PIPE
Piping material made from mild steel that is drawn through a die and welded. It is dipped in batch of zinc, which treatment serves to some degree protects the ipe against the effects of acids.
FLOOD LEVEL RIM
Which of the following is not a part of a typical trap.
BACK PRESSURE
Air pressure in the drainage pipes greater than the atmospheric pressure.
SANITARY WARE
Porcelain enamel ware, such as bathtubs, water closet, wash basins.
DOUBLE TEE
DOUBLE WYE
DOUBLE HUB
Prohibited fittings.
HIGHEST OPENING
In testing sanitary drainage pipes, all opening in the piping system should be closed except for the ____.
ALL OF THESE
Which will cause a slower drain in the floor drain?
a . accumulation of debris in the pipe
b. poor venting system
c. significant volume of suds
d. all of these
INDIRECT WASTE
How are pipes that discharge into a drainage system but which are not connected directly to the drainage system classified?
SLEEVES
What is a recession in a wall for holding pipes and conduits passing from floor to floor?
same gpm
How do you connect pump in series?