53 Terms

1
New cards

x-rays

cause biologic changes in living cells, adversely affects all living tissue

2
New cards

prescribing dental radiographs

This is based on the individual needs of the patient

3
New cards

FMX

Appropriate when a new adult patient presents with clinical evidence of generalized dental disease or history of extensive dental treatment

4
New cards

inherent filtration

Takes place when the primary beam passes through the glass window of the x-ray tube, the insulating oil, and the tubehead seal

5
New cards

inherent filtration

It does not meet the standards regulated by state and federal law

0.5-1.0 mm of aluminum

6
New cards

added filtration

An aluminum disk is placed between the collimator and tubehead seal

Filters low-energy and longer wavelength x-rays

7
New cards

total filtration

The sum of inherent and added filtration

Regulated by state and federal law

8
New cards

1.5 mm

Minimum total aluminum filtration for machines operating at 70kV or below

9
New cards

2.5 mm

Minimum total aluminum filtration for machines operating higher than 70kV

10
New cards

collimation

restricts the size and shape of the x-ray beam

11
New cards

round colliator

Located at the opening of the tubehead

Produces a cone-shaped beam 2.75 inches in diameter

12
New cards

rectangular collimator

Located at the opening of the tubehead

Exposes 60% less tissue than round option

13
New cards

PID

An extension of the x-ray tubehead used to direct the x-ray beam

Can be round or rectangular

14
New cards

16in rectangular

What is the recommended PID that is the most effective at reducing patient exposure

15
New cards

thyroid collar

A flexible lead shield placed around the patient’s neck

ONLY recommended for all intraoral exposures

16
New cards

lead apron

Placed over the patient’s chest and lap to protect the reproductive organs and blood forming tissues from scatter radiation

17
New cards

F-speed

Provides 20% more reduction exposure than E-speed

Kodiak InSight

18
New cards

beam alignment device

Stabilizes the receptor in the mouth and reduces the chance for movement

Eliminates the need for patient to hold receptor with a finger

19
New cards

60-80

What is the optimal kilovoltage setting

20
New cards

6-8

What is the optimal mliamperage setting

21
New cards

nondiagnostic images

must be retaken, resulting in additional radiation exposure for the patient

22
New cards

digital

Type of receptors that are most effective method of reducing a patient’s radiation exposure

23
New cards

primary beam

When taking radiographs, he dental radiographer must avoid the:

24
New cards

6 feet

The dental radiographer must maintain a distance of at least __ from the tubehead

25
New cards

inverse square law

The intensity of the beam diminishes as the distance from the source increases

26
New cards

90-135 degrees

What is the angle range the radiographer must be at in comparison to the beam

27
New cards

protective barriers

Leaded walls or lead doors that absorb the primary beam

28
New cards

film badge

Worn at waist level when taking radiographs

Mailed to the monitoring company once a month for evaluation

29
New cards

ALARA

as lows as reasonably achievable

Every possible method of reducing exposure to radiation should be employed

30
New cards

patient education

Explain the precautions taken for radiographs by talking about the prodcedure or providing a pamphlet

31
New cards

intraoral radiographic examination

A radiographic inspection of teeth and intraoral adjacent structures

Requires the use of intraoral image receptors

32
New cards

periapical, interproximal, and occlusal

3 Types of Intraoral Radiographic Examinations

33
New cards

periapical examination

Purpose: examine the entire tooth and 2mm of supporting bone

Technique: Paralleling and bisecting

Type of imaging receptor is in the name

34
New cards

interproximal examination

Purpose: examine the crowns of both the maxillary and mandibular teeth on a single film

Used for examining interproximal surfaces

35
New cards

bite-wing

What is the type of imaging receptor and technique used during interproximal examination

36
New cards

occlusal examination

Purpose: A larger film used to examine large areas of the maxilla or the mandible on one film

Film receptor type and technique is in the name

37
New cards

maximum permissible dose

Limit of ionizing radiation dose that a person is allowed to receive without incurring significant harmful side effects

38
New cards

50 mSv/year

What is the MPD of occupationally exposed people/radiographers

39
New cards

0.5 mSv/month

What is the MPD of pregnant dental personel during pregnancy months

40
New cards

1 mSv/year

What is the MPD of nonoccupationally exposed people

41
New cards

cumulative occupational dose

The accumulated lifetime radiation dose occupationally exposed workers must not receive

Calculation: worker’s age x 10 mSv

42
New cards

occlude

To close or to bite down

43
New cards

FMX

A series of intraoral dental images that show all the tooth-bearing areas of both jaws

Usually 14-20 images

44
New cards

tooth-bearing areas

The regions of the maxilla and mandible where the 32 teeth of the human dentition is normally located

45
New cards

dentulous

Areas of that exhibit teeth

46
New cards

edentulous

Areas where teeth are no longer present

47
New cards

FMX

Combination of periapical images and bite-wing images

48
New cards

diagnostic

Image that meets all the specific criteria for each intraoral image exposure

49
New cards

extraoral imaging examination

An inspection used to examine large areas of the skull or jaws

50
New cards

3

In order to take radiographs of a patient, How many years must have passed from their last FMX

51
New cards

0.25 mm

What is the minimum lead thickness needed for a lead apron to be effective

52
New cards

8in and 16in

What are the 2 sizes PID’s come in

53
New cards

round and rectangular

What are the two shapes PID’s come in