___________________ replaces the visual cues of density and contrast used in analog imaging systems.
exposure indicators
This is defined as the degree of geometric unsharpness or accuracy of structural lines recored in the image.
detail, definition, spatial resolution
How many shades of gray are possible with a 6 bit system?
64
Cassette-based digital radiography systems uses a ____________________ inside an imaging plate.
photostimulable storage phosphor
Digital images are made of discrete picture elements, or _____________________, arranged in a matrix.
pixels
With "direct digital" radiography, a cassette is not needed.
true
Direct acquisition systems utilize this as the detector.
amorphous selenium
With cassette-based digital systems, a thin film transistor (TFT) and individual detector elements collect the image.
false
In digital radiography, this type of system uses a two-part process that involves both a scintillator and a photodetector.
indirect acquisition
These collect the electrons given off by Amorphous Selenium or Amorphous Silicon.
DEL's
The two types of plate scanning mechanics found with cassette-based digital imaging include:
line scan and flying spot scan
What happens to the patient dose if I have a high DQE?
patient dose is decreased
As DQE decreases, the noise in a digital image is reduced.
true
An underexposure greater than 50% results in a loss of image contrast.
false
What is the function of a scintillator?
converts incoming x-ray photons to light
_______________________ is the range of under or overexposure that can occur in producing an acceptable image and does not violate ALARA.
exposure latitude
In digital imaging, exposure level and spatial resolution are closely associated.
false
With Carestream digital imaging systems, doubling the exposure increases the EI by 300.
true
With digital imaging, the latent image loses about ______________ of its energy in approximately 8 hours.
25
Digital imaging systems have an extremely high tolerance for patient overexposure.
true
This refers to the operational exposure level at which a digital imaging system is operated.
speed class
ADC stands for:
analog-to-digital converter
Smaller pixels equals greater detail.
true
With PSP imaging plates, the barcode reader must be read/scanned before an exam is performed.
false
With digital imaging, if the exposure field is not recognized accurately, a histogram analysis error followed by a rescaling error might occur.
true
The light guide assembly works much like fiber optic technology.
true
This device measures the exposure levels at the collimator and calculates as ESE based on this measurement.
DAP meter
___________________ is the reason why digital imaging systems can produce an image even when significant exposure error occur.
automatic rescaling
Direct acquisition radiography converts incoming x-rays directly to an electronic signal.
true
Which of the following vendors/brands utilizes a sensitivity number as their exposure indicator?
fuji, philips, konica
This may result in histogram analysis errors and rescaling errors.
inappropriate collimation and inappropriate beam alignment
Prior to image creation, the exposure values extracted from the PSP plates are subject to a process known as:
quantization
Excessive processing could result in an inaccurate dictation/diagnosis due to inappropriate default processing.
true
Quantization may sometimes be referred to as:
sampling frequency
With Priori Histogram Analysis, the standardized set of data comes from two or more pre-defined histograms.
false
The predetermined values used to create the digital image are known as:
values of interest
PSP's respond to an exposure as low as ____________ micro-roentgens.
60
Scatter radiation is not part of the useful beam.
true
Ways at reducing scatter radiation include which of the following:
beam limiting, optimal exposure, grid use, utilizing compression bands
Examples of beam limiting devices include all of the following except:
grids
With Neutral Histogram Analysis, a digital image is created after extracted data is matched to exams derived from experience of like subjects under ideal conditions.
false
Spatial resolution is one of the principal factors affecting the amount of scatter radiation produced.
false
Changes in kVp will not greatly affect radiographic contrast as it did with film-screen combinations.
true
To help avoid the Moire Effect a technologists should:
make sure that the grid line is not running in the same direction as the laser beam that is scanning the PSP, use high-frequency grid, use a grid with 103-178 lpi
Automatic rescaling can also be referred to as auto-ranging, rescaling, scaling, and normalization.
true
If you see gray areas outside the exposure field borders, a PSP exposure field recognition error might have occurred.
true
______________________ described the concept of density as it is displayed on a soft-copy monitor for digital image viewing.
brightness
Image contrast describes the difference between adjacent densities.
true
Excessive edge enhancement may cause this type of artifact:
halo
Digital filtering transforms images into their corresponding ____________________.
frequencies
Low-pass filtering may also be classified as smoothing and/or noise suppression.
true
smoothing greatly improves edge visibility.
false
Too much equalization can result in a poor image.
true
High-pass filtering either amplifies or deletes all but the low frequencies.
false
Scatter radiation is produced during _______________________ interaction.
compton
High-pass filtering may also be referred to as edge enhancement.
true
Equalization is a software function designed to even out the noise displayed in a digital image.
false
___________________ graphically represent a collection of exposure values extracted from the digital image receptor.
histograms
This term describes excessive equalization caused by a metal prosthesis.
metal mottle
An important step in the analysis of image data is recognizing exposure field borders.
true
The probability that an x-ray will interact with an image receptor depends on which of the following:
thickness of capture layer, atomic composition
Digital systems can be operated at a wide range of exposures, therefore making the term "speed" an inappropriate descriptor.
true
This is a measure of x-ray absorption efficiency.
DQE
Characteristics of PSP's include the following:
phosphor types, conversion efficiency, system speed class, detective quantum efficiency
With digital imaging systems, contrast is now unrelated to dose unlike analog film-screen systems.
true
You can not and should not collimate with digital imaging systems because it could result in a histogram error.
false
A partial loss of row of DEL's can be fixed easily because all you have to do is replace the individual DEL or row of DEL's.
false
Digital imaging systems are more sensitive to scatter and background radiation than analog film-screen systems.
true
With digital imaging systems, your kVp may be ___________________ higher than with analog film-screen systems.
5-15
________________________ is the rate at which x-ray energy is transformed into light in an intensifying screen.
conversion efficiency
With digital imaging systems, an additional 0.1-0.2 mm of copper filtration is recommended to reduce patient dose.
true
rescaling forces radiographers to look elsewhere for signs that a proper exposure was used to produce an image.
true
DQE is highest for __________________ systems and lowest for __________________ systems.
DR, analog film-screen
_____________________ refers to the tendency, with digital radiography, to gradually increase patient dose over time.
dose creep
You do not need to use a grid with digital imaging systems.
false
Digital imaging blur is caused by motion and changes in geometric factors.
true
needle crystals result in more light divergence when stimulated compared to turbid phosphor material.
false
Digital imaging is mAs driven.
false
Suggested ways aimed at controlling patient exposure with digital imaging systems include which of the following:
additional filtration, higher kVp levels, interfacing with AEC, maintain ALARA principles
Common image capture elements utilized with digital image receptor include all of the following except:
CaS
With the advent of digital imaging systems, it has become a lot harder for patient dose to be monitored.
false
Three main types of acceptance testing include all of the following except:
dark noise evaluation
Daily test regarding quality assurance includes what?
visual inspection, plate reader inspection, laser printer QC, monitor QC
Monthly QA test include all of the following:
PSP plate erasure, phantom image test, monitor calibration
Excessive dark noise improves the digital image.
false
Failure to demonstrate a uniformly bright image means that there may be a problem with the PSP plate or the reader (processor).
true
With image brightness uniformity, a ______% variation in pixel value is allowed.
10
Regarding digital imaging QA, this test assesses pixel values.
linearity and slope
With this test, a radiograph is processed through the PSP reader to determine if its edges, of the displayed image, are straight and continuous.
laser beam function
The high contrast resolution test uses a grid that measures line pairs per millimeter to assess the high contrast resolution capability of PSP systems.
true
If PSP imaging plate is not throughly erased, noise will be added to the next image.
true
The wire mesh test is utilized to access ___________________.
distortion
The daily monitor test is performed using which of the following test tool devices?
SMPTE test pattern, TG18QC test pattern
Part of the daily plate maintenance and cassette inspection involves checking the PSP imaging plate for cracked or broken hinges.
true
PSP imaging plates should be erased at least every 48 hours if they have not been in use.
true
If you come across a cracked or broken PSP imaging plate, just throw it in the garbage. It doesn't matter how you dispose it.
false
This refers to the number of pixels in a matrix and the size of the display screen.
spatial resolution
when viewed in a landscape format, lcd monitors typically have an aspect ratio of 4:3.
false
The gaps between pixels where no image information is displayed is called:
dead space
A bit depth of 1 equals a monochrome color display.
true