1
New cards

___________________ replaces the visual cues of density and contrast used in analog imaging systems.

exposure indicators

2
New cards

This is defined as the degree of geometric unsharpness or accuracy of structural lines recored in the image.

detail, definition, spatial resolution

3
New cards

How many shades of gray are possible with a 6 bit system?

64

4
New cards

Cassette-based digital radiography systems uses a ____________________ inside an imaging plate.

photostimulable storage phosphor

5
New cards

Digital images are made of discrete picture elements, or _____________________, arranged in a matrix.

pixels

6
New cards

With "direct digital" radiography, a cassette is not needed.

true

7
New cards

Direct acquisition systems utilize this as the detector.

amorphous selenium

8
New cards

With cassette-based digital systems, a thin film transistor (TFT) and individual detector elements collect the image.

false

9
New cards

In digital radiography, this type of system uses a two-part process that involves both a scintillator and a photodetector.

indirect acquisition

10
New cards

These collect the electrons given off by Amorphous Selenium or Amorphous Silicon.

DEL's

11
New cards

The two types of plate scanning mechanics found with cassette-based digital imaging include:

line scan and flying spot scan

12
New cards

What happens to the patient dose if I have a high DQE?

patient dose is decreased

13
New cards

As DQE decreases, the noise in a digital image is reduced.

true

14
New cards

An underexposure greater than 50% results in a loss of image contrast.

false

15
New cards

What is the function of a scintillator?

converts incoming x-ray photons to light

16
New cards

_______________________ is the range of under or overexposure that can occur in producing an acceptable image and does not violate ALARA.

exposure latitude

17
New cards

In digital imaging, exposure level and spatial resolution are closely associated.

false

18
New cards

With Carestream digital imaging systems, doubling the exposure increases the EI by 300.

true

19
New cards

With digital imaging, the latent image loses about ______________ of its energy in approximately 8 hours.

25

20
New cards

Digital imaging systems have an extremely high tolerance for patient overexposure.

true

21
New cards

This refers to the operational exposure level at which a digital imaging system is operated.

speed class

22
New cards

ADC stands for:

analog-to-digital converter

23
New cards

Smaller pixels equals greater detail.

true

24
New cards

With PSP imaging plates, the barcode reader must be read/scanned before an exam is performed.

false

25
New cards

With digital imaging, if the exposure field is not recognized accurately, a histogram analysis error followed by a rescaling error might occur.

true

26
New cards

The light guide assembly works much like fiber optic technology.

true

27
New cards

This device measures the exposure levels at the collimator and calculates as ESE based on this measurement.

DAP meter

28
New cards

___________________ is the reason why digital imaging systems can produce an image even when significant exposure error occur.

automatic rescaling

29
New cards

Direct acquisition radiography converts incoming x-rays directly to an electronic signal.

true

30
New cards

Which of the following vendors/brands utilizes a sensitivity number as their exposure indicator?

fuji, philips, konica

31
New cards

This may result in histogram analysis errors and rescaling errors.

inappropriate collimation and inappropriate beam alignment

32
New cards

Prior to image creation, the exposure values extracted from the PSP plates are subject to a process known as:

quantization

33
New cards

Excessive processing could result in an inaccurate dictation/diagnosis due to inappropriate default processing.

true

34
New cards

Quantization may sometimes be referred to as:

sampling frequency

35
New cards

With Priori Histogram Analysis, the standardized set of data comes from two or more pre-defined histograms.

false

36
New cards

The predetermined values used to create the digital image are known as:

values of interest

37
New cards

PSP's respond to an exposure as low as ____________ micro-roentgens.

60

38
New cards

Scatter radiation is not part of the useful beam.

true

39
New cards

Ways at reducing scatter radiation include which of the following:

beam limiting, optimal exposure, grid use, utilizing compression bands

40
New cards

Examples of beam limiting devices include all of the following except:

grids

41
New cards

With Neutral Histogram Analysis, a digital image is created after extracted data is matched to exams derived from experience of like subjects under ideal conditions.

false

42
New cards

Spatial resolution is one of the principal factors affecting the amount of scatter radiation produced.

false

43
New cards

Changes in kVp will not greatly affect radiographic contrast as it did with film-screen combinations.

true

44
New cards

To help avoid the Moire Effect a technologists should:

make sure that the grid line is not running in the same direction as the laser beam that is scanning the PSP, use high-frequency grid, use a grid with 103-178 lpi

45
New cards

Automatic rescaling can also be referred to as auto-ranging, rescaling, scaling, and normalization.

true

46
New cards

If you see gray areas outside the exposure field borders, a PSP exposure field recognition error might have occurred.

true

47
New cards

______________________ described the concept of density as it is displayed on a soft-copy monitor for digital image viewing.

brightness

48
New cards

Image contrast describes the difference between adjacent densities.

true

49
New cards

Excessive edge enhancement may cause this type of artifact:

halo

50
New cards

Digital filtering transforms images into their corresponding ____________________.

frequencies

51
New cards

Low-pass filtering may also be classified as smoothing and/or noise suppression.

true

52
New cards

smoothing greatly improves edge visibility.

false

53
New cards

Too much equalization can result in a poor image.

true

54
New cards

High-pass filtering either amplifies or deletes all but the low frequencies.

false

55
New cards

Scatter radiation is produced during _______________________ interaction.

compton

56
New cards

High-pass filtering may also be referred to as edge enhancement.

true

57
New cards

Equalization is a software function designed to even out the noise displayed in a digital image.

false

58
New cards

___________________ graphically represent a collection of exposure values extracted from the digital image receptor.

histograms

59
New cards

This term describes excessive equalization caused by a metal prosthesis.

metal mottle

60
New cards

An important step in the analysis of image data is recognizing exposure field borders.

true

61
New cards

The probability that an x-ray will interact with an image receptor depends on which of the following:

thickness of capture layer, atomic composition

62
New cards

Digital systems can be operated at a wide range of exposures, therefore making the term "speed" an inappropriate descriptor.

true

63
New cards

This is a measure of x-ray absorption efficiency.

DQE

64
New cards

Characteristics of PSP's include the following:

phosphor types, conversion efficiency, system speed class, detective quantum efficiency

65
New cards

With digital imaging systems, contrast is now unrelated to dose unlike analog film-screen systems.

true

66
New cards

You can not and should not collimate with digital imaging systems because it could result in a histogram error.

false

67
New cards

A partial loss of row of DEL's can be fixed easily because all you have to do is replace the individual DEL or row of DEL's.

false

68
New cards

Digital imaging systems are more sensitive to scatter and background radiation than analog film-screen systems.

true

69
New cards

With digital imaging systems, your kVp may be ___________________ higher than with analog film-screen systems.

5-15

70
New cards

________________________ is the rate at which x-ray energy is transformed into light in an intensifying screen.

conversion efficiency

71
New cards

With digital imaging systems, an additional 0.1-0.2 mm of copper filtration is recommended to reduce patient dose.

true

72
New cards

rescaling forces radiographers to look elsewhere for signs that a proper exposure was used to produce an image.

true

73
New cards

DQE is highest for __________________ systems and lowest for __________________ systems.

DR, analog film-screen

74
New cards

_____________________ refers to the tendency, with digital radiography, to gradually increase patient dose over time.

dose creep

75
New cards

You do not need to use a grid with digital imaging systems.

false

76
New cards

Digital imaging blur is caused by motion and changes in geometric factors.

true

77
New cards

needle crystals result in more light divergence when stimulated compared to turbid phosphor material.

false

78
New cards

Digital imaging is mAs driven.

false

79
New cards

Suggested ways aimed at controlling patient exposure with digital imaging systems include which of the following:

additional filtration, higher kVp levels, interfacing with AEC, maintain ALARA principles

80
New cards

Common image capture elements utilized with digital image receptor include all of the following except:

CaS

81
New cards

With the advent of digital imaging systems, it has become a lot harder for patient dose to be monitored.

false

82
New cards

Three main types of acceptance testing include all of the following except:

dark noise evaluation

83
New cards

Daily test regarding quality assurance includes what?

visual inspection, plate reader inspection, laser printer QC, monitor QC

84
New cards

Monthly QA test include all of the following:

PSP plate erasure, phantom image test, monitor calibration

85
New cards

Excessive dark noise improves the digital image.

false

86
New cards

Failure to demonstrate a uniformly bright image means that there may be a problem with the PSP plate or the reader (processor).

true

87
New cards

With image brightness uniformity, a ______% variation in pixel value is allowed.

10

88
New cards

Regarding digital imaging QA, this test assesses pixel values.

linearity and slope

89
New cards

With this test, a radiograph is processed through the PSP reader to determine if its edges, of the displayed image, are straight and continuous.

laser beam function

90
New cards

The high contrast resolution test uses a grid that measures line pairs per millimeter to assess the high contrast resolution capability of PSP systems.

true

91
New cards

If PSP imaging plate is not throughly erased, noise will be added to the next image.

true

92
New cards

The wire mesh test is utilized to access ___________________.

distortion

93
New cards

The daily monitor test is performed using which of the following test tool devices?

SMPTE test pattern, TG18QC test pattern

94
New cards

Part of the daily plate maintenance and cassette inspection involves checking the PSP imaging plate for cracked or broken hinges.

true

95
New cards

PSP imaging plates should be erased at least every 48 hours if they have not been in use.

true

96
New cards

If you come across a cracked or broken PSP imaging plate, just throw it in the garbage. It doesn't matter how you dispose it.

false

97
New cards

This refers to the number of pixels in a matrix and the size of the display screen.

spatial resolution

98
New cards

when viewed in a landscape format, lcd monitors typically have an aspect ratio of 4:3.

false

99
New cards

The gaps between pixels where no image information is displayed is called:

dead space

100
New cards

A bit depth of 1 equals a monochrome color display.

true