When will the D air removal pump start

4.2 condenser A

4.8 condenser B

5.3 condenser C

Inches mercury vacuum

New cards
2

Hogging valve alarm

if hogging valve is open will alarm due to unmonitored release path

New cards
3

Suction valve interlock on pump start

permissive

vacuum breaker is closed permissive for the suction valve

can only open on less than 1.5 HGA DP

Pump starts; discharge valve opens when 1.5 HGA DP is met

New cards
4

Purpose of AR pumps

establishes vacuum on startup and will remove non condensable gasses from the condenser

New cards
5

How is the release of the AR pumps monitored?

what happens when setpoint is met?

what does this indicate ?

Monitored for radiation by RU 141, when radiation levels are high it will send flow through the filter. starts the post filter blower.

indicates early indication of a SG tube rupture.

New cards
6

How many stages is the AR pump compressor

2 stages

New cards
7

where do the AR pumps discharge normally

Normally through the vent stack

New cards
8

How does Gland seal steam interface with the AR system? what about PW

the Gland seal steam system should be in service prior to placing AR in service

PW MUST be in service prior to placing AR in service

New cards
9

how does the condensate service header interface with AR system

Condensate system provides seal water to the AR pumps

New cards
10

what happens when the Hi radiation is detected and the valves fail to actuate

the indicating light will not illuminate until the valves are in the correct position