fire apparatus
fire department emergency vehicle used for rescue, fire suppression, or other specialized functions
NFPA 1901
Standard for automotive Fire Apparatus
pumper fire apparatus
bread and butter of the fire service. most common type of fire apparatus. terms pumper and engine are used interchangeably
miscellaneous equipment
portable tools and equipment carried on a fire apparatus, not including suction hose, fire hose, ground ladders, fixed power sources, hose reels, cord reels, breathing air systems, or other major equipment or components specified by the purchaser to be permanently mounted on the apparatus as received from the apparatus manufacturer.
initial attack fire apparatus
fire apparatus with a fire pump of at least 250 gpm capacity, water tank, and hose body, whose primary purpose is to initiate a fire suppression attack on structural, vehicular, or vegetation fires, and to support associated fire department operation
chassis
basic operating motor vehicle, including the engine, frame, and other essential structural and mechanical parts, but exclusive of the body and all appurtenances for the accommodation of driver, property, passengers, appliances, or equipment related to other than control. Common usage might, but need no, include a cab (or cowl)
mobile water supply apparatus
vehicle designed primarily for transporting (pickup, transporting, and delivering) water to fire emergency scenes to be applied by other vehicles or pumping equipment. also known as tanker or tender.
aerial fire apparatus
vehicle equipped with an aerial ladder, elevating platform, or water tower that is designed and equipped to support firefighting and rescue operations by positioning personnel, handling materials, providing continuous egress, or discharging water at positions elevated from the ground
aerial ladder
self-supporting, turntable-mounted, power-operated ladder of two or more sections permanently attached to a self-propelled automotive fire apparatus and designed to provide a continuous egress route from an elevated position to the ground.
quint
fire apparatus with a permanently mounted fire pump, a water tank, a hose storage area, an aerial ladder or elevating platform with a permanently mounted waterway, and a complement of ground ladders.
special service fire apparatus
designed for a particular purpose and does not quite fit into the other categories. ie; hazmat, heavy rescue
mobile foam fire apparatus
fire apparatus iwth a permanently mounted fire pump, foam proportioning system, and foam concentrate tank who primary purpose is use in the control and extinguishment of flammable and combustible liquid fires in storage tanks and other flammable liquid spills.
aircraft rescue and firefighting (ARFF) vehicle
vehicle intended to carry rescue and firefighting equipment for rescuing occupants and combating fires in aircraft at, or in the vicinity of, an airport.
6%
Apparatus must be able to maintain speed of at least 20 miles an hour on any grade up to and including
25 seconds
From standing start the apparatus must be able to attain a speed of 35 Miles per hour within____on a level Road
50 miles an hour
Apprentice must be able to attain a minimum top speed of____on a level Road
26,000 pounds
Maximum top speed of fire apparatus with a gross vehicle weight rating of more than______
750 gallons
Pumper must be equipped with a permit we mounted pump with a minimum rating of_____
300 gallons
Onboard water tank holding a minimum of
750 to 1000 gallons
Many engines have a tank size of at least 500 gallons although_______tanks are also very common
800 foot
Of 2 1/2 inch or larger supply/attack hose
400 feet
1 1/2 to 1 3/4 or 2 inch attack hose
200 GPM
One combination spray nozzle capable of delivering____at a minimum
95 GPM
Two combination spray nozzles capable of delivering____at a minimum
1, 1 1/8, 1 1/2, 1 1/4 tips
One play pipe, when shut off and
250 GPM
Initial attack fire apparatus pump must have a minimum rated capacity of______, in the apparatus water tank must have at minimum a certified capacity of 200 gallons
300 feet
Initial attack pumper must have______2 1/2 inch Or larger supply hose
400 feet
Initial attack pumper must have____ 1 1/2 to 1 3/4 or two inch Attack firehose
22 feet
Initial tech bumper mandates a minimum of_____and then close weather resistant compartments, which are to be used for storage of equipment
Overloading the chassis with too much weight
Because initial attack fire apparatus is built on a commercial chassis, there is a potential for
Mobile water supply apparatus
Equipped with a fire pump, 400 feet of 1 1/2 Or 2 inch attack hosing to combination spray nozzles with a minimum capacity of 95 GPM
115 foot
NFPA 1901, the apparatus must include at a minimum a_____total compartment of ground ladders that are supplied and installed by the manufacture
40 feet
Aerial apparatus must include a minimum of____of enclosed weather resistant compartment space for equipment
1 attic ladder
2 straight ladders with folding roof looks
2 extension ladders
1000 GPM
300 gallons
Quint fire apparatus minimum capacity water tank of____
85 feet
Minimum total compartment of____for ground ladders for quint fire apparatus
40 feet
Minimum enclosed resistant compartment space for storage of equipment for quint fire apparatus
120 feet
NFPA 1901 states it must have a minimum of____haven't close, weather resistant compartment space for storage of special service fire apparatus
Mobile foam apparatus
Shall be equipped with a fire pump that has a minimum rated capacity of 700 GPM, or an industrial supply pump that meets the requirements of NFPA 1901
500 gallons
Mobile phone fire apparatus shall be equipped with one or more foam concentrate tanks that meets the NFPA requirements and have a minimum capacity of
40 feet
Equipment storage on mobile foam fire apparatus must include a minimum of____of enclose weather resistant compartment space
Mobile water supply fire apparatus, tenders
Provide enough on board water to extinguish most fires that are held to only one or two bedrooms of a home