CompEx Practice Exam - Hazardous Area Certification and Safety

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/51

flashcard set

Earn XP

Description and Tags

Comprehensive Question and Answer flashcards derived from the CompEx practice examination notes covering ATEX directives, Ex concepts, cable installation, ingress protection, temperature classes, and inspection standards.

Last updated 9:15 AM on 9/5/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

52 Terms

1
New cards

What is the primary objective of European Directive ATEX 95?

To remove technical barriers to trade between member nations of the European Union.

2
New cards

Under ATEX 95 Directive, which equipment group and categories apply to non-mining gas or dust hazards?

Group II, Categories 1, 2, or 3.

3
New cards

What does the European Directive ATEX 95 specifically govern?

The design of equipment for use in potentially explosive atmospheres.

4
New cards

How does the installation standard BS EN60079-14 relate to IEC60079-14?

BS EN60079-14 is identical to IEC60079-14.

5
New cards

Which standard governs the installation of new equipment in potentially explosive gas atmospheres?

IEC60079-14.

6
New cards

Into which gas sub-division does Hydrogen fall?

IIC.

7
New cards

Into which gas sub-division does Acetylene fall?

IIC.

8
New cards

Into which gas sub-division does Ethylene fall?

IIB.

9
New cards

What is the temperature at which a gas/air mixture spontaneously ignites without an external ignition source called?

The ignition temperature.

10
New cards

What is the temperature at which a gas/air mixture ignites in the presence of an external ignition source called?

The flash point.

11
New cards

Which gas property dictates the selection of equipment's 'T' rating?

The ignition temperature of the gas.

12
New cards

What is the default design ambient temperature range for IEC 60079 equipment unless marked otherwise?

20oC-20^\text{o}\text{C} to +40oC+40^\text{o}\text{C}

13
New cards

What does the temperature classification ('T' class) of Ex equipment represent?

The maximum surface temperature reached by equipment in contact with flammable gas at maximum ambient conditions, which will not be exceeded in normal or specified fault conditions.

14
New cards

How many recognised temperature classes exist for Ex equipment?

6 (ranging from T1 to T6).

15
New cards

What is the maximum allowable surface temperature for equipment with temperature classification T5?

85oC85^\text{o}\text{C}

16
New cards

How is Zone 0 defined regarding the presence of an explosive gas/air mixture?

An area in which an explosive gas/air mixture is present continuously, for long periods, or frequently.

17
New cards

How is Zone 1 defined regarding the presence of an explosive gas/air mixture?

An area in which an explosive gas/air mixture is likely to occur in normal operation occasionally.

18
New cards

How is Zone 2 defined regarding the presence of an explosive gas/air mixture?

An area in which an explosive gas/air mixture is unlikely to occur in normal operation, and if it does occur, will persist for a short period only.

19
New cards

What Equipment Protection Level (EPL) and Category correspond to Zone 0?

EPL 'Ga' (Category '1G').

20
New cards

What Equipment Protection Level (EPL) and Category correspond to Zone 1?

EPL 'Gb' (Category '2G').

21
New cards

What Equipment Protection Level (EPL) and Category correspond to Zone 2?

EPL 'Gc' (Category '3G').

22
New cards

In which locations can intrinsically safe equipment marked Ex 'ib' be used?

Locations requiring EPL 'Gb' or 'Gc' (Categories '2G' or '3G').

23
New cards

In which locations can intrinsically safe equipment marked Ex 'ic' be used?

Locations requiring EPL 'Gc' (Category '3G') only.

24
New cards

Where can equipment marked Ex 'ia' be safely installed?

Locations requiring EPL 'Ga', 'Gb', or 'Gc' (Categories '1G', '2G', or '3G').

25
New cards

Which type of protection offers the highest level of safety and integrity?

Ex 'ia'.

26
New cards

Where can type Ex 'n' equipment be installed?

Locations requiring EPL 'Gc' (Category '3G') only.

27
New cards

Where can type Ex 'd' flameproof equipment be installed?

Locations requiring EPL 'Gb' or 'Gc' (Categories '2G' or '3G').

28
New cards

What does the letter 'U' appended to a certificate number signify?

The item is a component intended for incorporation in certified Ex equipment.

29
New cards

What does the suffix 'X' on a certificate number indicate?

Special conditions apply for safe use; refer to documentation.

30
New cards

What does the CE marking on an item of equipment indicate?

Compliance with all applicable European Union directives.

31
New cards

Why is flameproof (Ex 'd') apparatus given that designation?

An internal explosion will not ignite an external gas atmosphere.

32
New cards

What is 'pressure piling' in flameproof Ex 'd' enclosures?

A phenomenon where ignition in one part of an enclosure causes a higher explosion pressure in another interconnected part.

33
New cards

What do the two numbers following 'IP' in an Ingress Protection rating refer to?

Protection against solid matter (first digit) and water (second digit).

34
New cards

Which protection concept uses internal overpressure to prevent external flammable gas from entering equipment?

Ex 'p' (Pressurisation).

35
New cards

What is the minimum Ingress Protection (IP) rating required for an Ex 'e' junction box?

IP54.

36
New cards

What does 'te' time represent for an Ex 'e' motor?

The time to disconnection for a stalled motor starting from hot operating temperature.

37
New cards

What explosion protection technique is represented by Ex nA?

Non-sparking apparatus.

38
New cards

What is the main function of safety units such as Zener Barriers?

To limit the maximum energy transferred from power supplies to equipment in the hazardous area.

39
New cards

What does 'Um' on an intrinsically safe apparatus label specify?

The maximum r.m.s. supply voltage that can be applied to non-intrinsically safe terminals (typically 250 V250\text{ V}).

40
New cards

What is the minimum clearance distance between bare I.S. terminal conductors and earthed metal?

3 mm3\text{ mm}

41
New cards

What is the minimum clearance distance required between adjacent terminals of different intrinsically safe circuits?

6 mm6\text{ mm}

42
New cards

What is the minimum clearance distance required between live parts of I.S. terminals and non-I.S. terminals in the same enclosure?

50 mm50\text{ mm}

43
New cards

What is the minimum cross-sectional area required for aluminium cables used in hazardous areas for non-I.S. circuits?

16 mm216\text{ mm}^2

44
New cards

What is the minimum clearance distance between flanged openings in Ex 'd' IIC apparatus and solid obstructions?

Not less than 40 mm40\text{ mm}

45
New cards

What is the maximum allowable earth impedance for a Zener barrier earth connection?

Less than 1 ohm1\text{ }\text{ohm}

46
New cards

What minimum cross-sectional area copper conductor is required for single-wire earthing of a Zener barrier?

4.0 mm24.0\text{ mm}^2

47
New cards

What is the preferred identification color for intrinsically safe cables and equipment?

Light blue.

48
New cards

What is the maximum interval between periodic inspections for portable and transportable equipment?

6 months.

49
New cards

Which grade of inspection is required before equipment is brought into service upon handover?

Initial Detailed inspection.

50
New cards

What defines a Visual inspection in hazardous area maintenance?

An inspection which identifies defects apparent to the eye without using tools or access equipment.

51
New cards

At which grade of inspection is an Ex 'd' cable gland dismantled for examination?

Detailed inspection.

52
New cards

According to IEC 60079-14, what is the maximum allowable insulation resistance to protect new plastic-covered cable trays against static electricity?

Insulation resistance must not exceed 1 Gohm1\text{ G}\text{ohm}