What is an exit passageway?

Horizontal, fully enclosed, fire resistance rated portion of an exit that is used only as a means of egress to an exit discharge or a public way

<p>Horizontal, fully enclosed, fire resistance rated portion of an exit that is used only as a means of egress to an exit discharge or a public way</p>
2
New cards

When a door is approached perpendicularly to its opening, what is the minimum maneuvering clearance for wheelchair access at the strike side of the door opening on the pull side of the door?

18”

<p>18” </p>
3
New cards

Where can information be found regarding the code permitting process, the required fees for filing, the types of inspections required, and the powers of the building official?

The chapter on administrative requirements in a building code

4
New cards

Minimum clear floor space required to accomodate one stationary wheelchair

30” x 48”

5
New cards

What is fire resistance rated glazing?

Glass or other glazing material tested according to ASTM E119 as part of a fire resistance rated wall assembly

6
New cards

What percentage of the seating provided in restaurants, nightclubs, and churches must be accessible?

At least 5%

7
New cards

For an occupant load greater than 50, what is the absolute minimum corridor width?

44”

8
New cards

In a building equipped with sprinklers, when two exits are required in a space, what is the minimum separation required?

One third the diagonal distance of the space

9
New cards

What is an exit access travel distance?

Distance an occupant must travel from the most remote point within a building to the entrance of a nearest entrance

<p>Distance an occupant must travel from the most remote point within a building to the entrance of a nearest entrance</p>
10
New cards

What is a common path of egress travel?

The portion of an exit access that occupants are required to traverse before two separate and distinct paths of egress travel to two exits become available

<p>The portion of an exit access that occupants are required to traverse before two separate and distinct paths of egress travel to two exits become available</p>
11
New cards

What are the three parts of a means of egress?

  • exit access

  • exit

  • exit discharge


<ul><li><p>exit access</p></li><li><p>exit</p></li><li><p>exit discharge</p></li></ul><p></p>
12
New cards

Under what conditions would a wood veneer not have to adhere to flame spread requirements?

Less than 0.036” thick and applied to noncombustible material

13
New cards

Minimum diameter of a circle in which a wheelchair can turn?

60”

14
New cards

Maximum allowable projection of a door into a corridor when fully opened?

7”

15
New cards

How is minimum exit width calculated?

Multiplying the occupant load of a space by the appropriate factor given in the building code

16
New cards

On a commercial project, which professional on the design team must the interior designer coordinate with in regard to the location of audio and visual alarms?

Mechanical engineer

17
New cards

How is the occupant load of a space calculated?

Total area in square feet is divided by the occupant load factor

18
New cards

if an object is between 27” and 80” above the floor, what is the maximum allowable protrusion of that object from the wall?

4”

<p>4”</p>
19
New cards

How high above the floor must a grab bar be mounted?

Between 33” - 36”

<p>Between 33” - 36”</p>
20
New cards

What is maximum allowable slope for an accessible ramp?

1 vertical unit for every 12 horizontal units, or 8.33%

21
New cards

Two main factors in determining if a space requires two exits rather than just one?

Space’s occupancy and occupant load

22
New cards

Within a means of egress system, what are the exit access areas?

Areas that do not provide a protected path of travel and which leads to the entrance of an exit

<p>Areas that do not provide a protected path of travel and which leads to the entrance of an exit</p>
23
New cards

Minimum percentage of wall or ceiling area that combustible trim can occupy in a room?

No more than 10%

24
New cards

Generic name for fire rated gypsum wallboard

Type X

25
New cards

In accessibility regualtions, what type of provisions might require that a certain percentage of seating in an area be accessible?

Scoping provisions

26
New cards

What two situations require the construction of a fire barrier?

  • a separation where there are different occupancies

  • an enclosure where there are vertical exits


27
New cards

What is an intumescent material?

Material that, when exposed to heat, expands rapidly and insulates or fills spaces to prevent the passage of fire and smoke

28
New cards

What type of gypsum wallboard must be used for fire rated partitions

Type X

29
New cards

Minimum clear width of an accessible toilet staff?

60”

<p>60”</p>
30
New cards

To be classified as accessible, what is the maximum allowable vertical change in floor level?

Must not have a vertical change exceeding 1/4”

31
New cards

When a zoning ordinance does not allow a particular use for a building, what can the designer suggest to the client as a course of action?

Client apply to the zoning board for a variance to allow a nonconforming use

32
New cards

What is compartmentation in interior design?

Practice of separating areas of a building with fire rated construction in order to contain a fire to one area and limit its spread

33
New cards
<p>Minimum dimension for the space labeled A</p>

Minimum dimension for the space labeled A

32”

34
New cards

What is occupant load factor?

Amount of floor space that a building code presumes is occupied by one person in a particular occupancy

35
New cards

Where are detectable warnings required?

Walking surfaces in front of hazardous vehicular areas

36
New cards

What is an area of refuge?

Area of a building where persons unable to use stairways can safely await instructions or assistance during an emergency evacuation

37
New cards

In addition to a specific diameter and mounting height, what other handrail feature is required on an accessible stairway?

Must extend beyond the upper and lower risers

38
New cards

Minimum clear width of an exit door

32”

39
New cards

What is a public way?

Any street, alley, or similar parcel land unobstructed from ground to sky at least 10 feet wide and permanently appropriated to the public

40
New cards

According to the IBC. what is a fire partition and where is it used?

Wall assembly have a fire resistance rating of one hour, used in:

  • walls separating dwelling units

  • walls separating guest rooms in Group R-1, R-2, I-I occupancies

  • walls separating tenant spaces in covered malls

  • corridor walls


41
New cards

For an accessible ramp, what is the maximum rise allowed between landings?

No more than 30”

42
New cards

What are two things a designer must know about a space before the necessary number of exits can be determined?

Floor area and the occupancy group