BULLET/ SWALLOWED ITEMS, OBJECT INSERTED INTO BODY
FOREIGN BODIES
ARTIFICIAL JOINTS, SCREWS AND PLATES
PROSTHESIS
BARIUM/ IODINE
CONTRAST MEDIA
PACEMAKERS/ CHEST PORTS
IMPLANTS
JEWLERY OR PIERCINGS
REMOVEABLE
WHAT IS PACS
PICTURE ARCHIVING AND COMMUNICATION SYSTEM
- WHERE IMAGE CAN BE STORED ELECTRONICALLY
- SHARED WITH COMPUTERS OR SYSTEM
- SERVES AS ELECTRONIC FILE ROOM
- ACCESSION NUMBER ASSIGNED TO FILE PT HAS MRN/ EXAM HAS ACCESSION NUMBER
PACS
CHARACTERISITICS OF X-RAY
- INVISIBLE/ HIGHLY PENETRATING
- IONIZE MATTER
- STRAIGHT LINES
- TRAVELS SPEED OF LIGHT
- CAN CAUSE: BIOLOGICAL CHANGES, SCATTER, SECONDARY RADIATION
TYPES OF BACKGROUND RADIATION
- TERRESTRIAL
- INTERNAL SPACE
- RADON
- THORON
WHAT TYPE OF BACKGROUND RADIATION ACCOUNTS FOR MOST RADIATION (30%)
RADON & THORON
MOST RADIOSENSITIVE ORGANS
LENS OF EYE, THYROID, GONADS, BONE MARROW
ALARA STANDS FOR
AS LOW AS REASONABLY ACHIEVABLE
MINIMUM DISTANCE YOU SHOULD BE AT RADIATION EXPOSURE
6 FT
HIGH KVP =
LOW mAs
IR RECEIVED TOO MUCH RADIATION
OVEREXPOSED
IR DID NOT RECEIVE ENOUGH RADIATION
UNDEREXPOSED
SHORT EXPOSURE TIME REDUCES
MOTION BLUR
EVALUATE EXPOSURE
EXPOSURE INDICATORS
- RANGE SPECIFIC TO MANUFACTURER
EI EXPOSURE INDEX
DI STANDS FOR
DEVIATION INDEX
- MEASURES QUANTITY OF RADIATION RECEIVED
- WORN AT COLLAR LEVEL OUTSIDE/ LEAD COLLAR APRON
- RECEIVES EXPOSURE REPORT
DOSIMETER
OSL STANDS FOR
OPTICALLY STIMULATED LUMINESCENCE DOSIMETER
TLD STANDS FOR
THERMOLUMINESCENT DOSIMETER
- ALUMINUM OXIDE CRYSTALS
- MAXIMUM WEAR= 2 MONTHS
- SENSITIVITY- 1 MREM
OSL DOSIMETER
- LITHIUM FLOURIDE
- MAXIMUM WEAR= 3 MONTHS
-SENSITIVITY= 5 MREM
TLD DOSIMETER
ANODE IS WHAT CHARGE
POSITIVE
CATHODE IS WHAT CHARGE
NEGATIVE
WHAT METAL IS ANODE AND CATHODE MADE OF
TUNGSTEN
CATHODE IS THE SOURCE OF
ELECTRON
WHAT IS APPLIED TO ACCELERATE ELECTRONS
HIGH VOLTAGE (KVP)
ELECTRONS CRASH INTO WHAT TO PRODUCE X-RAYS
ANODE
X-RAYS ARE PRODUCED IN
CATHODE RAY TUBE
WHAT HAPPENS IF GLASS IS CRACKED ON X-RAY TUBE
CAN NO LONGER BE USED
RUNS THROUGH FILAMENT—-BECOMES HOT BOILING OFF ELECTRONS——THEN ACCELERATED TOWARD ANODE
THERMIONIC EMISSION
PERCENTAGE OF ENERGY IN THERMIONIC EMISSION RESULTING IN X-RAYS
1%
PERCENTAGE OF ENERGY IN THERMIONIC EMISSION RESULTING IN HEAT INSIDE TUBE
99%
HAVE TO TURN DIAL TO ADJUST SIZE OF LIGHT FIELD
MANUAL COLLIMATION
WHAT DOES PBL STAND FOR IN PBL COLLIMATION
POSITIVE BEAM LIMITATION
AUTOMATICALLY ADJUSTS BASED ON IR SIZE OR PART SELETED
PBL COLLIMATION
LENGTH OF TABLE
LONGITUDINAL
SIDE TO SIDE/ LATITUDINAL
TRANSVERSE
UP AND DOWN/ SID
VERTICAL
INDICATES ANGLE OF TUBE/ O DEGREES POINTED TO FLOOR
TUBE ANGLE INDICATOR
ALIGN TUBE TO BUCKY
DETENT
DOES TABLE TOP HAVE TO BE DETENTED?
NO
- WALL/ TABLE
- CONTAINS GRID
- PERMANENT/ REMOVEABLE
- TRAY GOES INTO IR
BUCKY
KILOVOLTAGE PEAK
kVp
SELECTS kVp APPLIED TO X RAY TUBE TO PRODUCE X-RAYS
kVp
CONTROLS ENERGY OF ELECTRONS & SUBSEQUENTLY ENERGY OF X-RAY BEAM
kVp
DIAGNOSTIC X-RAY RANGE FOR kVp
30- 150 kVp
kVp=
1000 volts
PENETRATING POWER/ QUALITY OF X-RAY
kVp
mA STANDS FOR
MILLIAMPERAGE
SELECTS X-RAY TUBE CURRENT ON CATHODE END OF TUBE
mA
CONTROLS # OF ELECTRONS PRODUCED BY THERMOIONIC EMISSIONS
mA
CONTROLS QUANTITY OF X-RAYS PRODUCED
mA
- CONTROLS AMOUNT OF X-RAY PHOTONS
- RADIATION EXPOSURE DELIVERED TO PATIENT OR INTENSITY OF BEAM
mA
MILLIAMPERAGE RAGE
50-1000 mA
- CONTROLS AMOUNT LENGTH/ EXPOSURE
- CONTROLS TIME ELECTRONS FLOW FROM CATHODE TO ANODE
- RANGES FROM MILLISECONDS TO 6 SECONDS
EXPOSURE TIME SELECTOR
MATHEMATICAL EQUATION FOR mAs
mA X s = mAs
- CONTROLS INITITATION OF EXPOSURE
- PREP HEATS CATHODE AND ROTATES ANODE
- WHEN EXPOSURE IS MADE & kV APPLIED ITS BEEPS
EXPOSURE SWITCH
WHAT DOES HOLDING DOWN ROTOR ON EXPOSURE SWITCH FOR EXTENDED TIME DO?
DECREASE LIFE OF X-RAY TUBE
AEC STANDS FOR
AUTOMATIC EXPOSURE CONTROL
- AUTOMATICALLY TERMINATED EXPOSURE WHEN PREDETERMINED AMOUNT OF EXPOSURE IS REACHED
AEC
PORTABLE FLUOROSCOPY UNIT
C-ARM
X-RAY EXITING TUBE
PRIMARY RADIATION
CHANGES DIRECTION WHEN X-RAY HITS BODY OR PART
SCATTER RADIATION
RADIATION THAT EXITS PATIENT AND REACHES IR
REMNANT RADIATION
REDUCTION DUE TO SCATTER AND ABSORPTION
ATTENUATION