1
New cards

Ground bearing floor infil

600mm max

2
New cards

Packing under sole plates

No more than 5mm

3
New cards

First joist to wall face

25-75mm

4
New cards

Floor expansion gap

10mm minimum

5
New cards

Intermediate expansion gap first floor

2mm per linear meter

6
New cards

Plywood panel floor expansion gap

1.5-2mm

7
New cards

Min clearance between glass edge and window frame

5mm

8
New cards

IGU edge clearance

3mm

9
New cards

Min edge cover to keep spacer below sight line and protect edge seal

12mm

10
New cards

Masonry - straightness in plan

8mm over 5m

11
New cards

Masonry - straightness in section

8mm up to 3m storey height

12
New cards

Masonry - plumb

8mm per storey up to 3m, 12mm total for taller walls

13
New cards

External reveals

4mm over 1m

14
New cards

Bed joint straightness

8mm over 5m

15
New cards

Bed joint thickness variation

1.5mm over 8 successive joints

16
New cards

Perpendicular joint alignment

15mm over 5 courses

17
New cards

Render flatness

4mm vertical and horizontal over 5m

18
New cards

Render cracks

Less than 2mm deep and 0.2mm wide

19
New cards

Curtain walling

2mm over storey height, 5mm overall

20
New cards

Rainscreen cladding

3mm across any storey height or structural bay width

21
New cards

Plastering and dry lining

3mm with a 450mm straight edge with equal offsets

22
New cards

Internal wall flatness

3mm with 2m straight edge with equal offsets

23
New cards

Internal walls plumb

8mm to 3m storey height. 12mm for taller

24
New cards

Ceiling level

3mm per 1m of ceiling up to 6m across

20mm max if over 6m across

25
New cards

Ceiling flatness

5mm to 2m level with equal offsets

26
New cards

Corner - external

5mm in 250mm

10mm in 500mm

27
New cards

Corners - Internal

5mm in 250mm

10mm in 500mm

28
New cards

Boxings

10mm deviation from square in 500mm

29
New cards

Sill flatness

3mm in every 2m

30
New cards

Heads and cills

3mm up to 1.5m

5mm where longer

31
New cards

Internal reveal plumb

3mm up to 1.5m

5mm where higher

32
New cards

Internal openings - Squareness

5mm up to 250mm deep

33
New cards

Sill level across reveal

3mm max across length

34
New cards

Window frames plumb

3mm up to 1.5m

5mm where higher

35
New cards

Internal door frames plumb

5mm max out of plumb one direction only

36
New cards

internal door jamb/ head gap

4mm max

37
New cards

Internal door distortion

5mm across height

3mm across width

38
New cards

Internal door - underside gap

10-22mm from unfinished floor

39
New cards

Internal door - finished floor

10mm gap

40
New cards

External door frames plumb

5mm max in one direction only

41
New cards

External door - distortion

5mm across height

3mm across width

42
New cards

Floors - level

3mm per 1m up to 6m across

20mm max if over 6m

43
New cards

Floor - Flatness

5mm with 2m level with equal offsets

44
New cards

Glazing - fine scratches

No more than 25mm long

45
New cards

Tile finishes - surface variation

3mm across 2m level with equal offsets

46
New cards

Adjacent floor tile level difference

1mm where joint less than 6mm

2mm where joint more than 6mm

47
New cards

Garage blockwork cracks

Up to 2mm wide

48
New cards

Drives and paths flatness

10mm across 2m level with equal offsets

49
New cards

Temporary standing water 1 hour after rain stops should not exceed….

5mm deep and 1m2

50
New cards