1/49
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
Ground bearing floor infil
600mm max
Packing under sole plates
No more than 5mm
First joist to wall face
25-75mm
Floor expansion gap
10mm minimum
Intermediate expansion gap first floor
2mm per linear meter
Plywood panel floor expansion gap
1.5-2mm
Min clearance between glass edge and window frame
5mm
IGU edge clearance
3mm
Min edge cover to keep spacer below sight line and protect edge seal
12mm
Masonry - straightness in plan
8mm over 5m
Masonry - straightness in section
8mm up to 3m storey height
Masonry - plumb
8mm per storey up to 3m, 12mm total for taller walls
External reveals
4mm over 1m
Bed joint straightness
8mm over 5m
Bed joint thickness variation
1.5mm over 8 successive joints
Perpendicular joint alignment
15mm over 5 courses
Render flatness
4mm vertical and horizontal over 5m
Render cracks
Less than 2mm deep and 0.2mm wide
Curtain walling
2mm over storey height, 5mm overall
Rainscreen cladding
3mm across any storey height or structural bay width
Plastering and dry lining
3mm with a 450mm straight edge with equal offsets
Internal wall flatness
3mm with 2m straight edge with equal offsets
Internal walls plumb
8mm to 3m storey height. 12mm for taller
Ceiling level
3mm per 1m of ceiling up to 6m across
20mm max if over 6m across
Ceiling flatness
5mm to 2m level with equal offsets
Corner - external
5mm in 250mm
10mm in 500mm
Corners - Internal
5mm in 250mm
10mm in 500mm
Boxings
10mm deviation from square in 500mm
Sill flatness
3mm in every 2m
Heads and cills
3mm up to 1.5m
5mm where longer
Internal reveal plumb
3mm up to 1.5m
5mm where higher
Internal openings - Squareness
5mm up to 250mm deep
Sill level across reveal
3mm max across length
Window frames plumb
3mm up to 1.5m
5mm where higher
Internal door frames plumb
5mm max out of plumb one direction only
internal door jamb/ head gap
4mm max
Internal door distortion
5mm across height
3mm across width
Internal door - underside gap
10-22mm from unfinished floor
Internal door - finished floor
10mm gap
External door frames plumb
5mm max in one direction only
External door - distortion
5mm across height
3mm across width
Floors - level
3mm per 1m up to 6m across
20mm max if over 6m
Floor - Flatness
5mm with 2m level with equal offsets
Glazing - fine scratches
No more than 25mm long
Tile finishes - surface variation
3mm across 2m level with equal offsets
Adjacent floor tile level difference
1mm where joint less than 6mm
2mm where joint more than 6mm
Garage blockwork cracks
Up to 2mm wide
Drives and paths flatness
10mm across 2m level with equal offsets
Temporary standing water 1 hour after rain stops should not exceed….
5mm deep and 1m2