Specialized imaging QNA

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/129

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 3:14 AM on 9/11/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

130 Terms

1
New cards

Common terminology that the radiologist uses to describe the image are the

imaging features.

2
New cards

The descriptor indicating the site where anatomic changes are evident is the

location.

3
New cards

The degree of vascularity of the abnormal tissues is described as the

vascularity (or perfusion) of the tissue

4
New cards

The most common imaging technique for diagnosing breast tissue today is

mammography (or ultrasound / screening mammography).

5
New cards

Beyond general radiography, the first new imaging modality was __ which produced images without the use of ionizing radiation.

Ultrasound

6
New cards

To visualize the fetus, today the safest modality is

ultrasound (or obstetric ultrasonography).

7
New cards

CAT stands for

computed axial tomography.

8
New cards

The first alternative to image the brain was provided by

computed tomography (CT)

9
New cards

What did computed tomography (CT) eventually replaced for brain imaging?

Pneumoencephalography

10
New cards

Scientists integrated strong magnets and radiofrequencies to develop

nuclear magnetic resonance (NMR)

11
New cards

nuclear magnetic resonance (NMR) Name today

magnetic resonance imaging (MRI)

12
New cards

Researchers developed a positron-emitting radiopharmaceutical to produce molecular images to create the newest modality

positron emission tomography (PET)

13
New cards

The modality that combines digital images using hybrid equipment or special software is

Fusion imaging

14
New cards

Sound waves produced by a transducer describe the imaging theory of?

ultrasound (or ultrasonography)

15
New cards

Sound waves passing through a water-tissue interface can produce reflections. These reflections are called

Echoes

16
New cards

In US, tissues transmitting sound waves easily are

anechoic (or sonolucent).

17
New cards

Strong reflections in US are called

hyperechoic or echogenic.

18
New cards

When two structures have the same echogenicity, the term

isoechoic

19
New cards

Doppler imaging is used to study

Blood flow

20
New cards

In Doppler imaging, color is used to represent the

Direction for flow and velocity for speed

21
New cards

Examples of acoustic barriers in US are

Air (or gas) and bone

22
New cards

Scanning using a narrow x-ray beam and computation of the attenuation coefficient, which is then displayed as a gray scale on the monitor, is

computed tomography (CT).

23
New cards

This reflects the specific tissue attenuation as relative to water in CT.

CT number (or Hounsfield unit [HU])

24
New cards

The highest CT number represents

Bone (+1000)

25
New cards

The areas that appear black on CT have the?

Lowest Ct number

26
New cards

High-resolution images indicate that the thin sections must be

1.5mm (or 2mm)

27
New cards

Multiple single-scan CT equipment has been replaced by

spiral (or helical) CT.

28
New cards

The newest CT scanners have ___ to produce 8 to 64 slices per scan rotation.

multidetector array systems

29
New cards

The seventh generation scanner collects data using a? and this is a multidetector scanner

Cone beam

30
New cards

Integrating all image data in CT by using software to produce 3-D images is

Volume rendering (or 3-D imaging / virtual reality) imaging

31
New cards

To enhance the CT image, ___ projections highlight the brightest pixels, improving the image.

Maximum intensity

32
New cards

To produce MR images, the technologist selects a pulse sequence that includes the RF pulse and its timing, which is usually represented by the

Repetition time and echo time.

33
New cards

The most commonly used pulse sequence in MRI is referred to as

Spin echo

34
New cards

Fat tissue, subacute hemorrhage, and highly proteinaceous material cause a high signal intensity that appears bright on

T1 weighted MR images

35
New cards

Blood flow is visualized as a

signal void (or black area / flow void)

36
New cards

To better demonstrate the blood vessels, ___ is administered for MR angiography examinations.

contrast agent (or gadolinium)

37
New cards

With the application of gradients, the random movement of water can be demonstrated in

diffusion-weighted imaging

38
New cards

To ensure a greater contrast difference between fat and water,

fat suppression (STIR) imaging

39
New cards

MR imaging visualizes blood transit time to help determine circulation in viable tissue.

Perfusion

40
New cards

Injecting a radionuclide and detecting the gamma radiation describe

Nuclear medicine

41
New cards

The dose of____is calculated on the basis of the specific half-life and decay rate.

Radiopharmaceutical (or radionuclide)

42
New cards

The decay of the radionuclide is detected for imaging purposes by a

Gamma camera

43
New cards

To gather data from the three-dimensional perspective, the use of a rotating gamma camera is used in

SPECT

44
New cards

SPECT meaning

Single-Photon Emission Computed Tomography

45
New cards

SPECT imaging is useful in evaluating

cardiovascular disorders, infections, tumors, and neurologic disorders, such as seizures and trauma.

46
New cards

The production of two high-energy photons in opposite directions is known as

Annihlation

47
New cards

PET is especially useful for imaging in

oncology, cardiology, and neurology.

48
New cards

In fusion imaging ____imaging is accomplished with the use of software and direct fusion imaging is a result of hybrid equipment.

Integrated imaging

49
New cards

A drug that emits radiation

radiopharmaceutical

50
New cards

Ability to combine images from different modalities into one image

fusion imaging

51
New cards

Allows for faster imaging and easy reformatting in the coronal and sagittal planes in CT

Helican or spiral scan

52
New cards

Produces images with high soft tissue resolution through the use of magnets and RFs

MRI

53
New cards

MRI meaning

Magnetic resonance imaging

54
New cards

Capable of producing images of the fetus without the use of ionizing radiation

Ultrasound

55
New cards

Compiles images to provide a 3D CT image, which is especially useful in visualizing the vascular system

Volume rendered imaging

56
New cards

CT numbers represent this value

Attenuation

57
New cards

Equipment designed to integrate multimodality images

Direct fusion

58
New cards

Gadolinium chelates are used to visualize the blood vessels

MR angiography

59
New cards

Has a gantry and x-ray tube, which rotates, producing cross-sectional images

Computed tomography (CT)

60
New cards

Hot spots indicate an increase in uptake that is directly proportional to the emission of gamma radiation

Nuclear medicine

61
New cards

Imaging especially useful in determining metastases in oncology patients to determine treatment

Positron emission tomography (PET)

62
New cards

In US, the term used when the organ tissues are very similar

Isoechoic

63
New cards

Localizes the specific regions of neurologic function of the brain

Functional MR

64
New cards

NM imaging with the addition of a rotating gamma camera

SPECT (single photon emission tomography)

65
New cards

On T1-weighted images, fat, subacute hemorrhage, and intravenous contrast material produce this signal

high signal intensity

66
New cards

The most common pulsing sequence(s) used in MRI today

T1/T2-weighted image

67
New cards

Radiopharmaceuticals are detected with this device

gamma camera

68
New cards

The time between the end of the last RF pulse and the point when the receiving coil listens for the signal

Echo time

69
New cards

The value given to the amount of attenuation in CT

CT number

70
New cards

3D rendering demonstrating the surface or selected structures

Computed tomography (CT)

71
New cards

Comparison of echo intensities for adjacent tissue

Ultrasound

72
New cards

Diameter or width and length (mm or cm)

Size

73
New cards

Heterogeneous (septate) or homogeneous (fluids)

Structure

74
New cards

High signals (bright) include fat, subacute hemorrhage, melanin, slow-flowing blood, and IV contrast

magnetic resonance imaging (MRI)

75
New cards

Indistinctly marginated (infiltration into surrounding tissue)

Demarcation

76
New cards

Nodular (tumor or lymph nodes) or reticular (resembling a net)

Shape

77
New cards

Relative to surrounding tissue (hyperdense or hypodense; radiolucent or radiopaque)

Density

78
New cards

Three planes of colored images to demonstrate the biochemistry of tissue (biologic map)

Positron emission tomography (PET)

79
New cards

Screening mammography images include

craniocaudal and mediolateral oblique projections

80
New cards

Imaging in ultrasound relies on a

transducer to receive and send sound waves

81
New cards

Air and bone are ______ in ultrasound.Helical scanning uses:

acoustic barriers

82
New cards

Helical scanning uses:

table movement during scanning , continuous x-ray exposure during scanning

83
New cards

Cross-sectional images produced by high-frequency sound waves is the modality known as:

Ultrasound (US)

84
New cards

In US, the transducer

records the changes in signal pitch and direction AND produces high-frequency sound waves

85
New cards

Tissue that is echo free or lacking in signal is:

anechoic

86
New cards

The CT number represents the

attenuation of specific tissue relative to water

87
New cards

The CT number representing bone (appearing white) is

+1000

88
New cards

The CT number representing Soft Tissue / Blood (appearing Gray) is

+20

89
New cards

The CT number representing Water (appearing Dark Gray) is

0

90
New cards

The CT number representing Fat (appearing Very dark Gray) is

-50

91
New cards

The CT number representing air (appearing black) is

-1000

92
New cards

High-resolution CT

requires thin section slices of 1.5 to 2 mm

93
New cards

In CT, the images that demonstrate the inside of a structure through reconstruction are called

virtual reality

94
New cards

The modality of choice for the spine and central nervous system is

MRI

95
New cards

The time it takes to play out the entire set of RF pulses before repeating is

Repition time

96
New cards

On MRI, blood flow is described as a

Signal void

97
New cards

Tissue suppression in MRI

creates a greater difference in tissue contrast is used in the neck, abdomen, and pelvis helps to differentiate tumor from normal tissue when the tissues are close in consistency

98
New cards

Molecular movement and random thermal motion are what ______ MR images rely on to produce an image.

Diffusion

99
New cards

Gamma radiation detected by a gamma camera is emitted by:

Radiopharmaceuticals

100
New cards

In the gamma camera, when the gamma rays interact with the crystals, they produce:

Light