Automatic Exposure Control (AEC)
The termination of an x-ray exposure based upon optimum x-ray energy being sensed by a solid-state detector. This is user-selectable and it’s accuracy is position-dependent
Auto-tracking
A feature of modern x-ray systems that enables simultaneous vertical movement of an upright image receptor and overhead x-ray tube
Anode
Positive electrode of the x-ray tube
Bucky Mechanism
Grid that is an integral part of the x-ray table, located below the tabletop and above a cassette receptor tray. It decreases the amount of scatter radiation reaching the image receptor, and can improve image quality. It also moves during exposure so that no grid lines appear on the image
Cassette
Lightproof holder for the image receptor. It may be a computerized radiography (CR) plate or a wireless, digital radiography (DR) panel
Cathode
Negative electrode of the x-ray tube
Collimator
An essential device designed to define the dimensions and direction of the x-ray beams. This device consists of four rectilinear, radiopaque blades that are adjustable to control the x-ray’s field size and shape. It may be operated manually or automatically.
Diagnostic Yield
The amount of clinically useful, diagnostic information that is produced by a medical imaging modality.
Digital Imaging
Acquisition of static images in an electronic fashion to create an electronic data set; conversion of images to a digital format for image manipulation, enhancement, archival, and networking; often referenced as DR (digital radiography)
Diode
Electrical component that possesses polarity with a negative and positive terminal
DR Panel
Common term for a flat-panel digital image receptor using either indirect or direct capture technology
Flat-Panel Detector (FPD)
Type of digital detector employing amorphous silicon or selenium material bonded with thin-film transistor technology for digital image creation and amplification.
Fluoroscope
Device used for dynamic radiographic examinations of patient physiologic functionality; consists of an x-ray tube and image receptor, aligned with each other in an orthogonal relationship; the x-ray tube and receptor may be above or below the patient depending upon system design
Fluoroscopy
Examination by means of the fluoroscope, employing image intensification or a flat panel detector
Goniometer
Angulation scale incorporated into the x-ray tube-head assembly to indicate the degree of x-ray tube angle, relative to the image receptor
Latent Image
Invisible image created electronically after x-ray exposure and before image processing
Linear Accelerator
A major piece of equipment used for radiation therapy to administer x-ray or electron energies in the treatment of malignant tumors
Longitudinal
Lengthwise, or along the long axis
Medical Image Management and Processing System (MIMPS)
Computer network for the transmission, viewing, and archival storage of medical images; often integrated into a larger hospital information system (HIS) and radiology information system (RIS); replacing the older term PACS
Orthogonal
A perpendicular relationship between the x-ray beam central ray (CR) and image receptor
Overhead Tube Crane OTC/3-D Suspension
Mechanical support for suspending the x-ray tube and collimator assembly from the ceiling of the radiography room
Picture Archival and Communication System(PACS)
Computer network for the transmission, viewing, and archival storage of medical images; often integrated into a larger hospital information system (HIS) and radiology information system (RIS)
Piezoelectric Crystal
An integral component of the ultrasound transducer that converts electrical energy into sound energies of various frequencies above the human audible range. These ____ also convert sound energy (echoes) into electrical signals that become the sonographic image
Positive Beam Limitation (PBL)
Form of automatic x-ray beam collimation of field size ensuring that the x-ray exposure field is no larger that the receptor size
Postprocessing
Manipulation of medical images after they have been acquired through x-ray exposure in order to improve image quality and diagnostic yield
Pulsed Progressive Fluoroscopy (PPF)
A fluoroscopic mode in which the fluoroscopic milli-amperage (mA) characteristics can be modified to maintain optimum image quality at a lower radiation dose; mA traits such as pulse height, pulse width, pulse rate and pulse interval can be altered to optimize image quality
Pyrex Glass
Can withstand very high temperatures from the x-ray tube anode
Primary Barrier
A receptor of x-radiation that intercepts the primary beam and prevents exposure if not interlocked with the central ray of the x-ray beam. In fluoroscopy, the fluoroscopic digital panel or image intensifier tube are _______.
Quantum Mottle
An undesirable image quality characteristic that shows image graininess and a loss in visual acuity; most often the result of underexposure to the receptor
Radiolucent
Describes a material that easily transmits x-ray energy with very little absorption
Radiopaque
Describes a material that absorbs x-ray energy, predominantly through the photoelectric effect
Real-Time Images
Images in which dynamic patient motion is visualized instantly as fluoroscopic imaging is occurring
Remnant Radiation
All radiation exiting the patient during exposure and ultimately striking the receptor
Soft Copy
Visualization of x-ray images using a video monitor for display and interpretation
Spot Image
Equipment that permits the acquisition of static images during a dynamic fluoroscopic examination; images acquired digitally and stored electronically
Telethrerapy
Administration of therapeutic dosages of x-radiation or electrons to patient anatomy from a distance, in order to treat malignant tumors
Tether
Electrical wire connection between a digital detector and the x-ray generator and computer
Transverse
Placed crosswise; situated at right angles to the long axis of a part
Tredelenburg Tilt
Table tilt angle in which the patient’s head and thorax are lower than their legs
Tube Angulation
Pivoting the tube at the point where it is attached to its support; measured and displayed in degrees
Vertical
Perpendicular to the plane of the horizon
X-ray Tube
Device that produces x-rays
X-Ray Tube Head
Equipment consisting of the x-ray tube, collimator, and operator controls; permits manipulation of the x-ray tube in many directions for proper positioning