Fill-in-the-blank practice flashcards covering power system grids, voltage classifications, distribution components, AC/DC comparison, Kelvin's Law, and cable types.

Last updated 3:13 AM on 8/30/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

18 Terms

1
New cards

NLDC stands for National Level Load Dispatch Centre, while SLDC stands for State Level Load __________.

Dispatch Centre

2
New cards

As of May/June 2026, India's target is to achieve 500GW500\,\text{GW} non-fossil capacity by 2030 and Net Zero by __________..

2070

3
New cards

In a primary transmission system, voltage is stepped up from 11kV11\,\text{kV} to values such as 132kV132\,\text{kV}, 220kV220\,\text{kV}, or __________.

400 kV

4
New cards

The secondary distribution system uses a 11kV/415V11\,\text{kV}/415\,\text{V} substation transformer with its secondary winding connected in __________.

Star

5
New cards

The main consideration in the design of a feeder is its __________ carrying capacity.

current

6
New cards

While designing a distributor, __________ along its length is the main consideration.

voltage drop

7
New cards

According to voltage classification, Ultra High Voltage (UHV) refers to voltages of __________ and above.

765 kV

8
New cards

According to IE Rule 55, the limit of frequency variation must not be more than __________.

±3%\pm 3\%

9
New cards

Underground cables categorized as Super Tension (S.T.) cables are designed for working voltages between 11kV11\,\text{kV} and __________.

33 kV

10
New cards

An H-type cable is suitable for operating voltages up to __________.

33 kV

11
New cards

A strategic, hours-long voltage sag caused by system overload to prevent a blackout is known as a __________.

brownout

12
New cards

Unlike AC transmission systems, DC transmission lines do not suffer from __________ effect.

skin

13
New cards

Steel-cored aluminum conductors on steel lattice towers are roughly __________ times cheaper than the equivalent underground cable.

16

14
New cards

The volume of conductor material required in a 3-phase AC transmission line is inversely proportional to V2cos2(ϕ)V^2 \cos^2(\phi), where cos(ϕ)\cos(\phi) is the __________.

power factor

15
New cards

Roughly, the most economical transmission voltage can be chosen as __________ per kilometer.

650 V

16
New cards

For overhead transmission lines, the breakeven distance where DC becomes more economical than AC is between 500km500\,\text{km} and __________.

800 km

17
New cards

Kelvin's Law states that the most economical conductor size occurs when the variable part of annual fixed charges equals the annual cost of __________.

energy wasted

18
New cards

Underground transmission systems are generally limited to working voltages up to __________.

66 kV