digital imaging CT

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/43

encourage image

There's no tags or description

Looks like no tags are added yet.

Last updated 3:22 PM on 9/4/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

44 Terms

1
New cards

ADC

converts analog info to digital, making the analog info useful to the computer

used for image processing and reconstruction in CT

2
New cards

steps of ADC

scanning

sampling

quantization

3
New cards

scanning

For the picture to be digitized it is separated into small regions on a grid (matrix)​

4
New cards

hounsfield unit

pixel

5
New cards

sampling

brightness of each pixel is measured

6
New cards

quantization

brightness value of the pixel is assigned

7
New cards

scan field of view

area to be imaged within the gantry

wherein raw data is collected

8
New cards

smaller

better: larger of smaller SFOV?

9
New cards

SFOV

determines the number of detectors collecting data per scan

10
New cards

reconstruction or display field of view

determines how much of the collected raw data is used to create an image

11
New cards

DFOV

equal to or less that the size of the SFOV

12
New cards

matrix

the computerized grid of data onto which the slice is placed for the purpose of reconstructing the density info

13
New cards

512×512

1024×1024

common CT matrix sizes

14
New cards

over the SFOV

where is the CT matrix placed

15
New cards

decreased

smaller matrix: increase/ decrease noise

16
New cards

smaller matrix

larger pixels

decreased spatial resolution

decrease noise

17
New cards

larger matrix

smaller pixels

increased spatial resolution

increase noise

18
New cards

pixel size (d)

= FOV / matrix

19
New cards

voxels - volume element

tissue volume

determined by multiplying the pixel size by the thickness of the CT image slice

20
New cards

voxel

(pixel size)² x slice thickness =

21
New cards

hounsfield units

the levels of brightness displayed on the monitor for each pixel

22
New cards

0

water CT number

23
New cards

1000+

dense bone CT number

24
New cards

-1000

air CT number

25
New cards

CT number

µt - µw X 1000µw =​

26
New cards

µw

attenuation coefficient of water

27
New cards

µt

attenuation coefficient of tissue

28
New cards

higher CT numbers

light shades of gray/ white

29
New cards

lower CT numbers

darker shades of gray/ black

30
New cards

attenuation

reduction i the intensity of the beam a sit passes through an object

31
New cards

windowing

adjusting the gray scale

32
New cards

256

monitor can detect how many shades of gray

33
New cards

window level (wl)

HU value of the area of interest

center of range

34
New cards

window width (ww)

range of grays (CT numbers)

determines the number of HUs represented on an image

35
New cards

white

numbers above range will be?

36
New cards

black

numbers below range will be?

37
New cards

lower contrast

larger window width

38
New cards

high contrast

smaller window width

39
New cards

calculate CT numbers HU

divide widow width in half

subtract the quotient form the window level for lower limit

add the quotient to the window level to determine upper limit

40
New cards

slice thickness

the width of the volume of tissue being examined (voxel)

41
New cards

anatomical coverage

noise in image

patient dose

what does slice thickness affect?

42
New cards

slice thickness

thickness of the x-ray beam / slices per rotation =

43
New cards

magnification

permit viewer to enlarge part of the reconstructed image on the monitor for viewing or filming

44
New cards

mag

allows for easier examination of image

enlarges the individual pixels

post processing done to the image not to raw data

“zoom in”