Anterior Lumbar

0.0(0)
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
Card Sorting

1/28

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

29 Terms

1
New cards

What is the INDEPENDENCE screw diameter

5.5 mm

2
New cards

What is the longest screw available in the ALIF Bone Screw Set

40 mm

3
New cards
<p>INDEPENDENCE: Identify the number corresponding to the part that will retract the exposed hex on the attachment point of the ALIF Inserter/Distractor</p>

INDEPENDENCE: Identify the number corresponding to the part that will retract the exposed hex on the attachment point of the ALIF Inserter/Distractor

2

4
New cards

INDEPENDENCE spacer is indicated for how many contiguous levels

2

5
New cards

INDEPENDENCE: How many mm is the posterior radiographic marker from the posterior edge

1.5 mm

6
New cards

INDEPENDENCE: the cephalad/caudal screw orientation is how many degrees

35

7
New cards

What are the sagittal profiles available with INDEPENDENCE

8, 15, 20 degrees

8
New cards
<p>INDEPENDENCE: Identify the number corresponding to the variable angled screw</p>

INDEPENDENCE: Identify the number corresponding to the variable angled screw

1

9
New cards

The INDEPENDENCE screws allows for how many degrees of conival variablity

5

10
New cards

T/F: INDEPENDENCE: The implant can’t be flipped, the one screw needs to be inserted into the inferior vertebrae

False

11
New cards
<p>INDEPENDENCE: Which number corresponds to the implant with the correctly positioned self-centering sleeve</p>

INDEPENDENCE: Which number corresponds to the implant with the correctly positioned self-centering sleeve

2

12
New cards

With the INDEPENDENCE medium spacers, what is the largest height available

21

13
New cards

What are the three INDEPENDENCE axial footprint options

24Ă—30, 26Ă—34, 29Ă—39

14
New cards

T/F: INDEPENDENCE MIS: The spacer should always be implanted as fas posterior as possible so that the positive stop on the triple barrel anchor guide contacts the vertebrae

False

15
New cards

INDEPENDENCE MIS: How can you ensure an anchor is correctly loaded into the triple barrel anchor guide

Choices:

- Lay instrument flat on the table

- Use the laser marked anchor indicator as a guide to the anchor orientation

- Use your thumb to secure the anchor in instrument

- Confirm that a click was felt or heard

- Confirm that anchors are fully seated

All of the Above

16
New cards

T/F: INDEPENDENCE MIS: Each anchor is to be incrementally impacted one at a time, using fluoroscopy to monitor the advancement of each anchor

True

17
New cards

INDEPENDENCE MIS: The triple barrel anchor guide will not disengage from the spacer, what can you advise the surgeon to do

Choices:

- Confirm the Hex Driver is fully seated into the Threaded Rod hex hole

- Rotate Hex Driver counterclockwise while simultaneously withdrawing the instrument, gently rocking left/right as needed.

All of the Above

18
New cards

INDEPENDENCE MIS: If an Anchor needs to be removed from the spacer once implanted, what should you advise the surgeon before the removal?

Choices:

- Confirm that the set screw has been rotated to the open position

- Confirm that the Freehand Inserter is attached to the spacer

- Confirm that the Anchor Removal Tool is fully threaded into the Anchor

- Both 1 and 3

Both 1 and 3

19
New cards

Which of the following sets do you need to do a MAGNIFY-S case?

Choices:

- 9126.9101- MAGNIFY™-S Instrument Set

- 9126.9102- MAGNIFY™-S 25x31 Implant Set

- 9126.9103- MAGNIFY™-S 26x34 Implant Set

- 9126.9104- MAGNIFY™-S 29x39 Implant Set

- 925.905- ALIF Instrument Set

- 925.906- ALIF Trials

- 925.907- ALIF Bone Screws

- 925.901- Anterior Disc Prep I

- 925.902- Anterior Disc Prep II

- All of the above

All of the above

20
New cards

MAGNIFY-S: Select the inserter(s) that allow placement of screw(s) with inserter attached to implant

Choices:

- Midline Inserter

- Offset Inserter

- Lateral Inserter

offset inserter and lateral inserter

21
New cards

T/F: MAGNIFY-S: When contracting the implant DO NOT use excess torque as implant integrity can be compromised

True

22
New cards

MAGNIFY-S: How many revolutions of torque limiting hex driver will result in 1mm expansion

1.5 revolutions

23
New cards

MAGNIFY-S: Can you pack into bone screw holes

No

24
New cards

MAGNIFY-S: The midline inserter does not attach to implant if set screws are in

Locked position

25
New cards

Which of the following in MONUMENT approved for

Choices:

- MONUMENT is approved as a stand-alone interbody fusion device

- MONUMENT is approved as a vertebral body replacement device

- MONUMENT is approved as an interbody fusion device with supplemental fixation (i.e. pedicle screws, facet fixation) from L1-S1

- MONUMENT is approved for the thoracic spine

MONUMENT is approved as an interbody fusion device with supplemental fixation (i.e. pedicle screws, facet fixation) from L1-S1

26
New cards

Which of the following is MONUMENT approved for?

Choices:

- Up to Grade 1 spondylolisthesis

- Up to Grade 2 spondylolisthesis

- Up to Grade 3 spondylolisthesis

- Up to Grade 4 spondylolisthesis

- Up to Grade 5 spondylolisthesis

Up to Grade 2 spondylolisthesis

27
New cards

How many millimeters of translation can MONUMENT achieve

8 mm

28
New cards

MONUMENT: One complete revolution of the IMPLANT REDUCTION DRIVER is

0.5 mm

29
New cards

MONUMENT: The implant reduction driver has a _____ hex with ____ of torque

2.5 mm hex with 1.5Nm of torque