What is the INDEPENDENCE screw diameter
5.5 mm
What is the longest screw available in the ALIF Bone Screw Set
40 mm
INDEPENDENCE: Identify the number corresponding to the part that will retract the exposed hex on the attachment point of the ALIF Inserter/Distractor
2
INDEPENDENCE spacer is indicated for how many contiguous levels
2
INDEPENDENCE: How many mm is the posterior radiographic marker from the posterior edge
1.5 mm
INDEPENDENCE: the cephalad/caudal screw orientation is how many degrees
35
What are the sagittal profiles available with INDEPENDENCE
8, 15, 20 degrees
INDEPENDENCE: Identify the number corresponding to the variable angled screw
1
The INDEPENDENCE screws allows for how many degrees of conival variablity
5
T/F: INDEPENDENCE: The implant can’t be flipped, the one screw needs to be inserted into the inferior vertebrae
False
INDEPENDENCE: Which number corresponds to the implant with the correctly positioned self-centering sleeve
2
With the INDEPENDENCE medium spacers, what is the largest height available
21
What are the three INDEPENDENCE axial footprint options
24Ă—30, 26Ă—34, 29Ă—39
T/F: INDEPENDENCE MIS: The spacer should always be implanted as fas posterior as possible so that the positive stop on the triple barrel anchor guide contacts the vertebrae
False
INDEPENDENCE MIS: How can you ensure an anchor is correctly loaded into the triple barrel anchor guide
Choices:
- Lay instrument flat on the table
- Use the laser marked anchor indicator as a guide to the anchor orientation
- Use your thumb to secure the anchor in instrument
- Confirm that a click was felt or heard
- Confirm that anchors are fully seated
All of the Above
T/F: INDEPENDENCE MIS: Each anchor is to be incrementally impacted one at a time, using fluoroscopy to monitor the advancement of each anchor
True
INDEPENDENCE MIS: The triple barrel anchor guide will not disengage from the spacer, what can you advise the surgeon to do
Choices:
- Confirm the Hex Driver is fully seated into the Threaded Rod hex hole
- Rotate Hex Driver counterclockwise while simultaneously withdrawing the instrument, gently rocking left/right as needed.
All of the Above
INDEPENDENCE MIS: If an Anchor needs to be removed from the spacer once implanted, what should you advise the surgeon before the removal?
Choices:
- Confirm that the set screw has been rotated to the open position
- Confirm that the Freehand Inserter is attached to the spacer
- Confirm that the Anchor Removal Tool is fully threaded into the Anchor
- Both 1 and 3
Both 1 and 3
Which of the following sets do you need to do a MAGNIFY-S case?
Choices:
- 9126.9101- MAGNIFY™-S Instrument Set
- 9126.9102- MAGNIFY™-S 25x31 Implant Set
- 9126.9103- MAGNIFY™-S 26x34 Implant Set
- 9126.9104- MAGNIFY™-S 29x39 Implant Set
- 925.905- ALIF Instrument Set
- 925.906- ALIF Trials
- 925.907- ALIF Bone Screws
- 925.901- Anterior Disc Prep I
- 925.902- Anterior Disc Prep II
- All of the above
All of the above
MAGNIFY-S: Select the inserter(s) that allow placement of screw(s) with inserter attached to implant
Choices:
- Midline Inserter
- Offset Inserter
- Lateral Inserter
offset inserter and lateral inserter
T/F: MAGNIFY-S: When contracting the implant DO NOT use excess torque as implant integrity can be compromised
True
MAGNIFY-S: How many revolutions of torque limiting hex driver will result in 1mm expansion
1.5 revolutions
MAGNIFY-S: Can you pack into bone screw holes
No
MAGNIFY-S: The midline inserter does not attach to implant if set screws are in
Locked position
Which of the following in MONUMENT approved for
Choices:
- MONUMENT is approved as a stand-alone interbody fusion device
- MONUMENT is approved as a vertebral body replacement device
- MONUMENT is approved as an interbody fusion device with supplemental fixation (i.e. pedicle screws, facet fixation) from L1-S1
- MONUMENT is approved for the thoracic spine
MONUMENT is approved as an interbody fusion device with supplemental fixation (i.e. pedicle screws, facet fixation) from L1-S1
Which of the following is MONUMENT approved for?
Choices:
- Up to Grade 1 spondylolisthesis
- Up to Grade 2 spondylolisthesis
- Up to Grade 3 spondylolisthesis
- Up to Grade 4 spondylolisthesis
- Up to Grade 5 spondylolisthesis
Up to Grade 2 spondylolisthesis
How many millimeters of translation can MONUMENT achieve
8 mm
MONUMENT: One complete revolution of the IMPLANT REDUCTION DRIVER is
0.5 mm
MONUMENT: The implant reduction driver has a _____ hex with ____ of torque
2.5 mm hex with 1.5Nm of torque