Incident Command System (ICS)
The system that will always be used at incident scenes.
Four tactical objectives of command
Remove endangered occupants; stabilize the incident/provide life safety; conserve property; provide safe accountability and welfare of personnel.
Ongoing aspect of an incident
Safe accountability and welfare of personnel.
Primary functions of command
Assume/announce command, size up, control communications, establish strategy/incident plan, organize command, revise the plan, and provide for transfer/termination of command.
Command radio designation
Identified as "Command" followed by the geographical location of the incident.
Initial command initiation
The first arriving fire rescue member/unit initiates command upon arrival.
First-arriving radio report contents
Unit designation, situation description, obvious conditions, strategy, safety considerations, and assumption/identification of command.
Three levels of command
Strategic, tactical, and task.
Strategic level operator
Incident Command.
Tactical level operator
Division/group officers.
Task level operator
Company officers.
Coordination level operator
Branch officers.
Three resource deployment types
Single resources, task forces, and strike forces.
Task force definition
Any combination of single resources temporarily assembled to perform group functions.
Strike force definition
A set number of resources of the same kind and type.
FLOP meaning
Finance, Logistics, Operations, Planning.
Section providing facilities, services, and materials
Logistics.
Section handling tactical priorities and personnel safety/welfare
Operations.
Section responsible for information analysis for decision-making
Planning.
Maximum recommended span of control
No more than 5 divisions/groups in fast-moving complex operations.
Engine company functions
Search, rescue, treatment, stretch hose, operate nozzle, and loss control.
Functions not performed by engine company
Ventilation or forcible entry.
Ladder company functions
Search, rescue, treatment, ventilation, forcible entry, raising ladders, access, and checking fire extension.
Rescue company functions
Search, rescue, treatment, RIT, and general firefighter duties as assigned.
Ladder functions when no ladder company is available
Performed by an engine crew assigned by command.
Proper-code automatic fire alarm response
1 engine.
First-alarm structure-fire assignment
3 engines, 1 ladder, 1 rescue, 1 BC.
Response for alarm with smoke, smell of smoke, water flow, or electrical involvement
First-alarm structure-fire response.
Response assigned to a pull-station fire alarm
First-alarm structure-fire response.
Level 1 staging definition
Automatically used for incidents involving a first-alarm assignment; uncommitted units stage approximately one block away in their direction of travel.
Level 2 staging usage
When command wants a reserve of resources or centralized resources on scene.
Level 2 staging automatic implementation
Greater alarms and incidents requiring large amounts of manpower/equipment.
Determiner of Level 2 staging location
The Staging Officer.
Second alarm assignment
An additional 2 engines.
Third alarm assignment
An additional 2 engines and 1 BC.
Automatic alarm for a large commercial working fire
Second alarm.
Automatic alarm for a working high-rise fire
Third alarm.
"Nothing Showing" indication
Investigating.
Three major apparent-condition reports
Nothing showing, smoke showing, and fire showing, with working fire/fully involved also used.
Characteristics included in size-up
Occupancy, size, and height.
Assumed building height unless reported otherwise
One story.
"Working fire" indication
Commitment of all responding companies and an incident expected to extend beyond 30 minutes.
Fireground progress benchmarks
Water flowing, fire under control, primary search complete, secondary search complete, salvage/overhaul, fire out, utilities secured, investigator needed, and Red Cross needed/not needed.
"Fire under control" meaning
Forward progress has stopped and remaining fire can be handled with resources on scene; it does not mean the fire is completely out.
Basic tactical priorities
Rescue/primary search, fire control, and loss control.
Seven sides of a division considered by command
Front, rear, right, left, top, bottom, and interior.
First priority in defensive operations
Personal safety.
Second defensive priority
Protect exposures.
Third defensive priority
Knock down the main body of fire.
Evaluation of conditions for defensive operations
Should occur after 10–15 minutes of interior operations with heavy fire.
Minimum crew size inside the hot zone
2 personnel.
Action with serious fatigue in crew members
The entire crew should be reassigned to Rehab.
Recommended work period before mandatory Rehab
Two air bottles or approximately 45 minutes.
Three passport colors
Primary = white; backup = green; reserve = red.
Location of the primary passport
On the company officer’s radio.
Location of the backup passport
In the engine.
Location of the reserve passport
In the command vehicle.
When a PAR is required
Missing/trapped firefighter, offensive-to-defensive transition, sudden hazardous event, primary-search all-clear, every 30 minutes, fire under control, or when command/safety determines it necessary.
Initial accountability officer
The first engineer on scene, until relieved.
Accountability officers' operational location
Outside the hot zone at the point of entry.
Signs of potential structural collapse
Cracks, bulges, movement sounds, smoke/water leakage, floor/roof movement, leaning/twisting columns or walls, sagging roof lines, and prolonged fire involvement.
Expansion of 100 feet of unprotected steel at 1,000°F
Approximately 9 inches.
Most likely failing part of a fire-involved building
The roof.
Evacuation signal
Three 5-second horn blasts.
High-rise definition under the study guide
A building higher than two stories or one that cannot be accessed with a 24-foot ground ladder.
Location of the high-rise resource area
Two floors below the fire floor or another safe location below the fire.
Lobby control establishment
The first arriving engineer establishes lobby control.
Lobby control management aspects
Elevators, stairwells, building communications, ground-level system controls, and equipment movement.
Maximum crews in an elevator at one time
No more than 2.
Initial elevator destination
Two floors below the suspected fire floor.
Usage restriction for elevators
Should not be used without fire override control or when smoke/fire is visible in the shaft.
Recommended high-rise perimeter for falling glass/debris
Approximately 200 feet.
Major functions of an engineer/driver
Maintaining, driving, pumping, and testing fire apparatus.
Main purpose of a fire pumper
Provide adequate water pressure for effective fire streams.
Minimum pump capacity for standard fire apparatus
750 GPM.
Minimum water tank capacity
300 gallons.
Minimum capacity for a mobile water supply apparatus
1,000 gallons.
Two basic mobile water-supply functions
Shuttle operations and nurse-tender operations.
Function of an inverter
Converts 12/24V DC to 110–220V AC.
Maximum capability for a vehicle-mounted generator
Up to 12,000 watts.
Operational readiness test definition
Inspection ensuring apparatus/equipment are present, clean, and ready for service.
Functional check definition
Operating a specific apparatus system/component to ensure it functions properly.
Frequency of apparatus brake testing
At least annually.
Air-pressure protection valve operation
Prevents nonessential devices from operating below 80 psi.
Brake fade definition
Loss of braking function from excessive brake use.
Common location for emergency apparatus collisions
Intersections.
Action before passing through an intersection with a red light
Come to a complete stop.
Distance between multiple responding apparatus
300–500 feet.
Total stopping distance definition
Reaction distance + braking distance.
Visual lead time definition
Time needed to stop or perform an evasive maneuver at the current speed.
Recommended collapse zone for apparatus positioning
1½ times the building height.
Safest apparatus position if collapse occurs
The corner of the building.
Positioning for hazardous-liquid incidents
Uphill.
Positioning for wildland fires
Downhill.
Reason to position apparatus upwind
To reduce the possibility of the apparatus becoming an exposure.
Standard nozzle pressure for a smooth-bore handline
50 psi.
Standard nozzle pressure for fog nozzles
100 psi.
Standard pressure for a smooth-bore master stream
80 psi.
Friction loss for a master-stream device
25 psi.
Key Engineer quick-reference numbers for 1¾-inch handlines
100 ft of Green FDNY = 20 psi; Red Sniper = 30 psi; Yellow/White BIG10 = 30 psi.