DC Practical Damage Control/Compartmentation Frequently Tested Questions And Verified Answers With Rationales

0.0(0)
studied byStudied by 0 people
0.0(0)
full-widthCall Kai
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/80

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

81 Terms

1
New cards

On isometric damage control diagrams, what type of information is indicated by dotted lines?

Hidden boundaries, piping, and valves

2
New cards

What term is used to describe the division of the interior areas of a ship's hull into smaller spaces by the use of structural members?

Compartmentation

3
New cards

What do the four parts of a compartment number identify?

Deck number, frame number, position of compartment relative to centerline, compartment use.

4
New cards

List five of the eight subgroup items that may appear on a CCOL.

Access, misc classification, drainage system, plumbing drains, fire-main and sprinkling, sound tube valve and fitting, ventilation system, portable damage control equipment.

5
New cards

When set, provides the least amount of watertightness

X-ray

6
New cards

Set and maintained at sea, and when leaving and entering port during peacetime.

Yoke

7
New cards

Set when general emergency is sound

Zebra

8
New cards

Set when darken ship is required

Dog zebra

9
New cards

Fittings that serve vital piping and ventilation

William

10
New cards

When is the damage control closure log required to be maintained?

At all times

11
New cards

On the damage control closure log, what three items of information are provided in the column titled "identification of fittings"?

Type, number, classification

12
New cards

While in port, at home port, what condition is set and maintained as a minimum between the hours of 0630-1900 daily?

X-ray

13
New cards

Besides identifying the space, what other information is identified on the compartment bull's-eye?

Division responsible

14
New cards

Which of the following correctly identifies classification tags attached to fittings?

Zebra fitting have red tags: X-ray, yoke, Williams and dog fittings have black tags.

15
New cards

All sounding tube caps will be classified __.

Circle X-ray

16
New cards

Which type of fitting does NOT need to be logged each time the ship's material condition is set or checked?

Out of commission fittings

17
New cards

What can be used to plug or patch a hole?

Anything available

18
New cards

How many gallons of water per minute will flow through a 4in hole at 6ft below water line?

770 gal per min

19
New cards

Cover holes with jagged edges protruding inward, held in place by shoring or welding.

Box patch

20
New cards

Covers holes with jagged edges protruding inward, held in place using a folding T-bolt.

Bucket patch

21
New cards

Used for protruding outward holes.

Plate patch

22
New cards

Used on small (18" or less) inward protruding holes. Usually round and hinged through the center

Hinge patch

23
New cards

What two types of personal protection safety equipment should always be used when plugging or patching?

Helmet, steel-toe boots

24
New cards

What are three types of patches used on pipes for repair?

Jubilee, soft patch, syntho-glass

25
New cards

Which type of patch is modification of a commercial hose clamp?

Jubilee

26
New cards

What fibrous material is used to wrap around a plug or wedge prior to inserting?

Oakum

27
New cards

Which type of pip patching should NOT be used with high-pressure steam lines?

Soft patch

28
New cards

After patching a pipe with syntho-glass, how long should you wait before restoring pressure to the piping system?

30 minutes

29
New cards

What two pieces of personal protection equipment must be worn when using syntho-glass patches?

Eye protection, latex gloves

30
New cards

What two chemicals can be used on the skin to remove resin in the syntho-glass patch?

Alcohol, acetone

31
New cards

When flooding is discovered, what are the four most important pieces of info to pass as soon as possible?

Location, type of flood, depth of flood, source of flood

32
New cards

What are the three dewatering systems most typically installed on Coast Guard Vessels?

Installed Eductors, installed pumps, installed gravity drains

33
New cards

What valve on the installed Eductor system must be open to avoid accidental back flushing?

Discharge valve

34
New cards

What are three commonly installed pumps used to dewater ship spaces?

Fire pump, ASW pump, ballast pump

35
New cards

Which of the following is NOT a component of the electric submersible pump?

Check valve

36
New cards

List three methods in which the sub pump can be used to dewater a space.

Submersed, without submersing, in series

37
New cards

What two things must you do when operating the sub pump out of water?

Attach foot valve/strainer, prime the pump by filling it with water

38
New cards

What are jet-type pumps that contain no moving parts called?

Eductors

39
New cards

When using a portable Eductor, back flushing ante caused by what?

Restriction in discharge hose, insufficient water pressure

40
New cards

Why should you NOT use the CG-P6 pump below decks or in confined space?

Risk of Carbon monoxide poisoning

41
New cards

List four major components in shoring operations.

Shore, shore, strong back, wedge

42
New cards

Which of the following is an advantage of using wood shoring versus metal shoring?

Can be cut to exact size

43
New cards

What method of shoring is the simplest and strongest?

Direct pressure, I type

44
New cards

What is another name for the triangulation method of shoring?

K type

45
New cards

What is the weakest method of shoring?

Cross axial, H type

46
New cards

What is used to layout "K" type shoring when a shoring batten is not available?

Carpenters square, folding rule (or tape measure)

47
New cards

When laying out shoring with a framing square, what is used to determine the length of the shore and the angles that must be cut on each end of the shore?

Rise, run

48
New cards

When passing metal shoring, you must always keep the screw jack end in what direction?

Down

49
New cards

When shoring a watertight door or hatch with six dogs, how many shoring pressure points should be applied?

Six

50
New cards

When should the DC closure log be updated?

When there is a change in the status of a classified closure or fitting

51
New cards

What material condition must be set while underway?

Yoke

52
New cards

What is the simplest method of plugging a small hole?

Square-end plugs

53
New cards

What is the very first entry made at the top of a DC message blank?

Time

54
New cards

What does a casualty letter designation within a circle mean on the DC message blank?

Casualty engaged

55
New cards

Which of the following pipe patches requires 30 minutes for complete curing?

Syntho-glass

56
New cards

Which of the following pumps used a Venturi effect to draw water out of a space?

Eductors (jet-type pump)

57
New cards

Which of the following pumps requires use of a 2 1/2in discharge hose?

Submersible pump

58
New cards

Which of the following equipment can be used to lower the sub pump into a flooded compartment?

Basket strainer

59
New cards

Which of the following pumps is capable of delivering over 250 gpm at a 12ft suction lift through a 3in diameter suction hose?

CG-P6 portable pump

60
New cards

A flat plate or block that can be placed under the end of a shore to span irregularities is a __.

Shole

61
New cards

What is the simplest and strongest shoring method?

Direct pressure

62
New cards

In which type of shoring is forced exerted across the grain (long axis) of the shore?

Cross axial

63
New cards

The length of a shore should NEVER be more than how many times its minimum thickness?

30

64
New cards

What can be used to quickly determine the required length and angles to be cut for shoring?

Batten

65
New cards

When shoring doors and hatches, the basic rule is to put how many points of pressure on the closure?

One for every dog on the closure

66
New cards

Damaged pipes can normally be isolated by closing a __ on each side of the damaged section of pipe.

Cutout valves

67
New cards

List three piping systems that should be repaired immediately if damaged.

Firemain, ASW, chill water

68
New cards

What is the disadvantage of rigging a jumper system between fire stations?

Lose the use of two fireplugs for firefighting

69
New cards

What gate(s) do you remove from the fireplugs to rig a temporary jumper between fire hose stations to bypass damaged pipe?

WYE

70
New cards

What should you use to hold flanges in place on both sides of a replaced ruptured section of pipe?

Bolt or C-clamps

71
New cards

How should you normally isolate/bypass a damaged piping system?

Close the cutout valves

72
New cards

What is the QUICKEST way to bypass a ruptured pipe and restore pressure to the rest of the firemain?

Rig a jumper

73
New cards

What kind and size of thread should a flange have to rig a bypass for damaged pipe?

Male, 2 1/2in

74
New cards

When repairing a ruptured firemain using fireplugs, what should you use to connect the two lengths of hose?

2 1/2in female coupling

75
New cards

What document provides an itemized list of all classified fittings and closures used by DC personnel to set specific material conditions of readiness?

Compartment check-off list

76
New cards

Under what section on the CCOL will you find information that tells damage control petty officers which fittings are opened or closed when material conditions are set?

Material condition status

77
New cards

Which of the following headings is NOT used by the Coast Guard on the CCOL?

Oxygen, nitrogen, and inert gas valves

78
New cards

Which of the following should NOT be used to verify fitting information on the CCOL?

Naval engineering manual

79
New cards

Fireplugs are not classified, but they are required to be numbered and listed under which of the following CCOL sections?

Firemain, sprinkling and washdown

80
New cards

In which document can you verify the pipe runs and fittings listed on the CCOL?

DC diagrams

81
New cards

Recommended changes to the CCOL or DC Books MUST be submitted __.

Through the chain of command to ELC-02