1/143
Looks like no tags are added yet.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai |
|---|
No study sessions yet.
false
true or false
The Architectural Design Process is a one size fits all process, every project follows the process exactly
Pre design
what architectural design process where the client selects an architect and the architect produces a design program
design program
a brief detailing the clients expectations and or needs for the work commissioned. it also includes the design requirements
Schematic design
what architectural design process where we search for an essential organizing principle, an idea that will suggest the overall arrangement and form of spaces
true
true/ false
Drawings at the schematic design phase
must be detailed enough to calculate a
rough estimate of its construction cost.
design development
what architectural design process where cost estimate is prepared, project schedule is reviewed, and what is produced in this phase is presented to the client for review and approval
contract documents
what architectural design process produces working drawings and specifications
bidding and negotiation
what architectural design process helps the client get the best or lowest deal
construction administration
what architectural design process where portions of the documents l be used by each of the many subtrades that carry out specific parts of the work
supplemental services
what architectural design process where other services stipulated in the contract within the services of the architect are presented
minimum=largest, maximum=smallest
what do you do in case of conflicting provisions with other code references
2.7m
what is the minimum ceiling height for a naturally ventilated floor
2.7m
minimum ceiling height for an artificially ventilated floor, 1st flr
2.4m
minimum ceiling height for an artificially ventilated floor, 2nd flr
2.1m
minimum ceiling height for an artificially ventilated floor, 3rd flr
1.8m
MINIMUM CEILING HEIGHT FOR MEZZANINE
6ss1m, 2m one side
minimum room size and area for human habitation
3sqm, 1.5m one side
minimum kitchen area
1.2sqm, 0.9m one side
minimum area of toilet and bath
10% of floor area, not less than 1sqm
for a room without artificial ventilation what is the minimum window opening
5% of floor area, not less than 240sqmm
window opening for toilets, bathroom, laundry room
750mm from side or rear property line
depth of eaves, canopies, awnings
.82x1m
what is the minimum dimension of windows for emergency egress
<0.82m
how far should the window for emergency egress be from the floor
0.90M
door opening as per the NBCP
0.71M
door opening as per fire code
1.2m
door leaf width as per nbcp
1.22m
door leaf width as per fire code
2
number of exits required as per fire code
60m nbcp, 61m fire code
max distance to exits as per nbcp and fire code with sprinkler
45m nbcp, 46m fire code
max distance to exits as per nbcp and fire code without sprinkler
1.12/1.1m
minimum corridor width
6m
max length of corridor with dead end
false, width of stairs should be equal with landing
true or false
if my stair width is 1.2m, my landing can be measured 1m
>100mm
for stairs and landing it should not be reduced in width by ______________ by a door when fully open
3.6m
maximum vertical distance between landings
2m
minimum headroom clearance for stairs
false
true or false:
i can consider that my site has a parking if there is a vacant lot beside me that is not part of my site or on the street
2.5x5m
parking slot dimension for diagonal and perpendicular
2.15x6m
parking slot dimension for parallel parking
3x9m
parking slot dimension for jeepney/ shuttle
3.6x12m
parking slot dimension for trucks or bus
3.6x18m
parking slot dimension for articulated trucks
2m
windows or balconies facing a neighbors property should be setbacked how many meters
1/3 of setback
maximum building projection
development controls
a set of interacting regulations concerning the physical utilization of a lot and governing the planning and design of spaces and or the use or occupancy of a building to be introduced
total lot area
the surface area of a property on which a building is proposed to be built
setback
horizontal distance measured 90 deg from the property line to the outermost face of the building
yard
area of required open space within a lot that is essential to allow light and ventilation in the building
Percentage of Site Occupancy
the percentage of the maximum allowable enclosed floor area of any building in relation to the TLA
AMBF/TLA
pso=________ /__________
ALLOWABLE MAXIMUM BUILDING FOOTPRINT
The maximum portion of the lot which may be occupied by the building at grade level after satisfying setback, yard, and court requirements
PSO x TLA or TLA-Area of yard
AMBF formula
Gross Floor Area
the total floor space within the perimeter of the permanent external walls of the building
TLA x FLAR
formula for GFA
Floor to Lot Area Ratio
the ratio between the GFA of a building and the TLA of the lot on which it stands
total gross floor area
the total floor space within the main and auxiliary buildings and all other enclosed support areas, together with all other usable horizontal areas/ surfaces above
TOTAL OPEN SPACE WITHIN LOT
the total open space required for each type of use or occupancy for a given lot expressed as percentage of the TLA
IMPERVIOUS AND UNPAVED SURFACE AREA
2 types of TOSL
IMPERVIOUS SURFACE AREA
the percentage of the maximum allowable floor area of any paved, tiled, or hardscape surface at the grade level outside the building inn relation to the TLA
UNPAVED SURFACE AREA
the portion of the lot reserved for plants and softscapes
maximum allowable construction area
area within the lot that can be paved, regardless of whether it is enclosed by a wall or not
condominium
what do you call an apartment with facilities
10%
how many percent of total accessible units should a single detached and duplex have
1 accessible unit per 26-50 units, plus 1 per 100 thereafter
accessible unit for school/ company, multiple dwelling units, high rise condo building according to bp344
ingress level
accessible units should be located where according to bp344
not allowed, abutment only
firewall size for an R1 zoning
80% of 1 side only
max length of firewall for R2
85% of each 2 sides, total must not exceed 65% of total lot perimeter
max length of firewall for R3
10m, 1.5
bhl and flar of r1
10m, 1.3-1.5
bhl and flar of basic r2
15m, 2.1-3
bhl and flar of max r2
10m, 1.8-2.1
bhl and flar of basic r3
36m, 7.1-8.1
bhl and flar of max r3
10m, 1.6-1.8
bhl and flar of r4
36-54m, 6-9
bhl and flar of r5
total area of sides and rear yards
where do you base the impervious surface area for an R1 zoning
15
hotels are buildings or group of buildings under the same management in which there are more than _____ sleeping accommodations for hire
lodging/ rooming house
what do you call a building or group of buildings in which separate sleeping rooms are rented providing sleeping accommodation for 15 people or fewer
1 accessible unit per 50units up to 150 units, plus 1 per 100 thereafter
for hotels how many accessible units should you have according to bp344
1 star
PH DOT- Star grading system
budget, limited facilities
2 star
PH DOT- Star grading system
more than basic accommodation
3 star
PH DOT- Star grading system
good level of accommodation
4 star
PH DOT- Star grading system
upscale in all areas
5 star
PH DOT- Star grading system
luxury and sophistication
front of the house, back of the house
general categories of space in a hoitel
apartelle
has several independent, furnished or semi furnished apartments, regularly leased to tourists and travellers for dwelling on a longer term basis
25
how many uinits should an apartelle have
pension house
It is a private or family-operated tourist boarding house, tourist guest house, or tourist lodging house employing non-professional domestic helpers regularly catering to tourists and travelers, containing several independent lettable rooms, providing common facilities such as toilets, bathrooms/showers, living and dining rooms and/or kitchen and where a combination of board and lodging may be provided.
5m
recommended setback for educational facilities from the street to reduce noise
10000
minimum lot area for rural elementary school
15000
minimum lot area for rural secondary school
5000
minimum lot area for urban elementary school
6000
minimum lot area for urban secondary school
7x9m
minimum classroom size according to DepEd
400sqm
minimum area of library in a school
up to 70% of the total perimeter of the property (except residential)
Under Section 704 of the NBCP, what is
the maximum length of firewall that can be
built, provided that the subject building
complies with the requirements stipulated?
1 every 10 classroom
public school minimum parking slot required
1 every 5 classrooms, 1 bus for every 100 students
private school minimum parking slot required
1 loading bay for 2 queued jeep slot
jeep loading bay requirement for both public and private school