FC A School Basic Alarms

0.0(0)
studied byStudied by 0 people
GameKnowt Play
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
Card Sorting

1/46

encourage image

There's no tags or description

Looks like no tags are added yet.

Study Analytics
Name
Mastery
Learn
Test
Matching
Spaced

No study sessions yet.

47 Terms

1
New cards

Buzzers that are AC operated have __________ contacts.

No

2
New cards

A ________________ current runs between the alarm module and the resistor.

6 Volts

3
New cards

What component enables a horn to produce sound?

Diaphragms

4
New cards

What are the three conditions that result from an alarm module regarding the monitoring of the return current?

Normal, Alarm, and Trouble.

5
New cards

Where is the supervisory resistor placed in the circuit?

Parallel to the alarm contacts of the last sensor in the contact.

6
New cards

True or False. The supervisory resistor monitors the sensor, not the electrical connections.

False

7
New cards

What audible signal device is used in quiet spaces?

Buzzer

8
New cards

What are the types of Horns used in the alarm safety and warning systems?

1. Motor-operated

2. Non-resonated

3. Resonated

9
New cards

What does "Dials" refer to on the visual indicator?

Number of lights on the indicator.

10
New cards

How are lights connected in the visual indicator?

In parallel and mounted behind each dial.

11
New cards

What are the 3 major units of the detector head in an lonization detector?

1. Outer Chamber

2. Inner Chamber

3. Cold Cathode Tube

12
New cards

Name the seven types of switches used with the alarm systems.

1. Liquid level float

2. Manual

3. Mechanical

4. Mercury Thermostatic

5. Thermostatic

6. Pressure

7. Water

13
New cards

How many sets of contacts does a single-pole, single-throw switch have?

1 set

14
New cards

What makes the IC/DM door mounted switch "tamper proof"?

Because there are 2 sets of switches, one for the switch cover and one for the door itself.

15
New cards

What acts as the conductor in the water switch, shorting the contacts to activate the alarm?

The presence of salt water.

16
New cards

What switch is used with the high temperature alarm system (CKT F)?

IC/J thermostatic switch

17
New cards

What are the temperature ranges of the mercury thermostatic switch and what are their colors?

RED - 105°F used in magazines.

BLACK 125°F used in storerooms and paint lockers.

BLUE 150°F used in all other spaces (ie. mess, decks, berthing, and office.

18
New cards

What are the two switch types and circuit designations of liquid level float switches?

Water (IC/RL and CKT FD) and Oil (IC/RH and CKT TD)

19
New cards

What is the only switch with a single pole double throw?

Door mounted switch

20
New cards

What is the switch type and circuit designation of a pressure switch?

IC/L and CKT N/A

21
New cards

Which liquid level float switch is reversible and is used with oil applications?

IC/RH

22
New cards

A sensitive switch is also referred to as a ____________________.

micro switch

23
New cards

The components of the liquid level float switch are contained within a __________________ cylinder housing.

Clear

24
New cards

The supervisory resistor must be placed at the ____________ of a circuit.

End

25
New cards

What type of switch is activated by the pressure or vacuum of a gas or liquid?

Pressure switches

26
New cards

What type of sensing device is used to sense gas or smoke?

Ionization Detectors

27
New cards

What type of switch is operated by the physical movement of a mechanism?

Mechanical switches

28
New cards

___________ use internal circuitry to activate an alarm that alerts personnel of hazardous conditions.

Detectors

29
New cards

The alarm switchboard is a(n) ______________ system installed onboard ship for the detection and warning of a variety of important functions or conditions that require continuous monitoring.

Electrical

30
New cards

What is the circuit designation of the liquid level alarm?

TD

31
New cards

What is the circuit designation of the magazine sprinkling alarm?

FH

32
New cards

What is the circuit designation for the high temperature (fire) alarm?

F

33
New cards

What part of the Alarm, Safety and Warning System monitors selected spaces and equipment?

Alarm switchboards and panels.

34
New cards

What is the circuit designation of the secure communications space door alarm (intrusion).

DL

35
New cards

What is the circuit designation of the flooding alarm?

FD

36
New cards

What is the circuit designation of the high security alarm (classified)?

FZ

37
New cards

What is the circuit designation of the airflow indicator alarm?

HF

38
New cards

Water Switch

knowt flashcard image
39
New cards

Mercury Thermostatic Switch

knowt flashcard image
40
New cards

What tool do you use on switches or detectors?

Burnishing tool

41
New cards

What common faults do you get on switches?

Pinched wires and broken terminal lugs (connections).

42
New cards

What is the switch type and circuit designation of a thermostatic switch?

IC/N and CKT N/A

43
New cards

What is the switch type and circuit designation of a mercury thermostatic switch?

IC/J and CKT F

44
New cards

What is the switch type and circuit designation of a door mounted switch?

IC/DM and CKT FZ

45
New cards

What is the switch type and circuit designation of a water switch?

IC=N/A and CKT FH

46
New cards

What is the switch type and circuit designation of a water liquid level float switch?

IC/RL and CKT FD

47
New cards

What is the switch type and circuit designation of a oil liquid level float switch?

IC/RH and CKT TD and is reversible.