One-Hour Fire-Resistive Occupancy Separation
Two-Hour Fire-Resistive Occupancy Separation
Four-Hour Fire-Resistive Occupancy Separation
where all openings are protected by a fire-assembly with a designated hour resistive rating.
Three-Hour Fire-Resistive Occupancy Separation
where wall openings in any one-storey cannot exceed 25% of the wall length
no single opening shall have an area greater than 10.00sq. meters
and floor openings are protected by vertical enclosures with two-hour fire-resistive
Adjacent Property Line
For property location purposes under Section 704, the centerline of an adjoining street or alley is considered an
750millimeters from the side and rear property lines.
Eaves over required windows shall not be less than
Allowable Maximum Building Footprint (AMBF)
The resultant area established at grade level upon which a proposed building or structure may stand, measured horizontally from property lines or firewalls to the outermost exterior walls.
Low Density Residential (R-1) Firewall Exception
R-1 occupancies strictly prohibit firewalls, except for a carport roof support abutment up to 3.20meters high from grade, constructed of perforated/decorative concrete blocks above 1.50meters, with a length not exceeding 7.00meters or 50% of the side property line.
Medium Density Residential (R-2) Firewall Restriction
Firewalls for R-2 occupancies may only be erected on one side property line up to a maximum of 80% of its total length.
Townhouse Residential (R-4) Firewall Restrictions
Firewalls permitted on two side property lines up to a maximum of 85% of each side line's length, not exceeding 50% of the total lot perimeter, allowed for a maximum three-storey structure.
Residential Condominium (R-5) Two-Side Firewall Allowance
Firewalls on two sides allowed up to 75% of each side line length, max 50% of total perimeter, restricted to a maximum eight-storey podium structure.
Total Gross Floor Area (TGFA)
The allowable maximum gross floor area of a proposed building based on lot type percentages and storey multipliers, which must not exceed the Allowable Maximum Volume Building (AMVB).
Building Height Limit (BHL)
The maximum permitted height for buildings measured from established grade line to the topmost portion, excluding permitted roof projections such as signage, masts, antennas, and telecom towers.
Established Grade (Sloping Grade <= 3.00 meters)
When the elevation difference along the footprint perpendicular to the RROW is less than 3.00meters, the highest adjoining natural grade or finished sidewalk grade is the established grade.
Established Grade (Sloping Grade > 3.00 meters)
When the elevation difference along the footprint perpendicular to the RROW exceeds 3.00meters, the average grade level of the building footprint is considered the established grade.
Combustible Spire and Tower Height Extension
Spire, tower, or steeple projections of combustible materials not used for habitation or storage may extend a maximum of 6.00meters above the prescribed Building Height Limit (BHL).