1
New cards
The body coil is an example of what type of coil?
A. Surface/Local coil
B. Parallel imaging coil
C. Volume coil
D. Phased array coil
volume Coil
2
New cards
Which type of coil allows the signal from the receiver of each coil to combine to form one image?
A. Surface/Local coil
B. Volume Coil
C. Parallel imaging coil
D. Phase array coil
Phase array coil
3
New cards
Which type of coil is used to image structures near the skin surface?
A. Phased array coil
B. Parallel imaging coil
C. Volume Coil
D. Surface/Local coil
Surface/Local Coil
4
New cards
Which type of coil uses the latest available technology to combine signal from multiple coils and simultaneously reduce scan time?
A. Surface/Local coil
B. Volume Coil
C. Parallel imaging coil
D. Phased array coil
Parallel Imaging Coil
5
New cards
When positioning the coil for scanning a patient, the technologist should:
A. Ensure the coil is plugged in properly and that the correct connector box is used.
B. Ensure that the coil has freedom to move as needed for the exam.
C. Ensure the coil is touching the anatomy to be imaged.
D. Ensure that the receiving surface of the coil is perpendicular to the Z axis of the magnet.
Ensure the coil is plugged in properly and that the correct connector box is used
6
New cards
Head normal mode limit
38 Celsius or 3.2 W/kg averaged over head mass
7
New cards
Torso normal mode limit
39 Celsius or 10 W/kg over any 10g
8
New cards
Extremities normal mode limit
40 Celsius of 10 W/kg over any 10g
9
New cards
The abbreviation MRA stands for:
MR Angiography
10
New cards
The abbreviation SAR stands for:
Specific Energy Absorption Rate
11
New cards
Which of the following patient injuries can be caused by improper placement of cardiac leads?
A. Patient burns
B. Temporary hearing loss
C. Short term memory loss
D. All of the above
Patient burns
12
New cards
Thorough patient prep should include which of the following?:
A. Proper Patient screening
B. Complete patient medical history
C. Adequate patient education
D. All of the above
All of the above
13
New cards
Gradient noise associated with high magnetic fields requires that patients use:
Earplugs
14
New cards
All claustrophobic patients that are scheduled for MRI examinations should be:
Handled delicately so as not to compound their anxiety
15
New cards
Which of the following is NOT a consideration of image quality?
A. Patient throughput
B. Scan Time
C. Contrast to noise ratio
D. Signal to noise ratio
Patient throughput
16
New cards
MRI is based on signal received from the patient. The signal is measured by the:
A. Strength of the magnet
B. Fluctuation temps within the magnet
C. Voltage induced in the receiver coil
D. Constant value received in the coil from the area under examination
Voltage induced in the receiver coil
17
New cards

The background electrical noise of the MRI system and the introduction of a patient into the MRI scanner combine to create:

A. Increased signal (SNR)

B. Increased field strength

C. Short scan times

D. Increased noise

Increased Noise Signal to noise is a ratio (SNR)

18
New cards
SNR will be decreased with all of the following EXCEPT:
A. Thin slices
B. Short NEX/NSA
C. Large FOV
D. Wide receive bandwith
Large FOV
19
New cards
The difference in SNR between 2 adjacent areas is known as:
contrast to noise
20
New cards

The ability to distinguish between two points as separate and distinct entities is known as:

A. Contrast to noise

B. Spatial resolution

C. Magnetization transfer

D. Signal to noise

B. Spatial resolution

21
New cards
Image contrast between pathology and normal tissue may be increased by all of the following EXCEPT:
A. Use of contrast media
B. Use of T2 weighted sequences
C. Use of T1 weighted sequences
D. Use of chemical pre-saturation
Use of T1 weighted sequence
22
New cards
Spatial resolution may be increased with the use of:
A. thin slices
B. fine matrices
C. small FOV
D. all of the above
D. All of the above
23
New cards
Scan time will be increased by using:
A. a coarse matrix
b. thick slices
c. the lowest NEX possible
d. a long TR
D. A long TR
24
New cards
Spin echo (SE) sequences are the most commonly used pulse sequences because:
A. They are always the fastest available scans
B. They are useful for visualization of blood dynamics
C. They produce optimum SRN and CRN
C. They produce optimum SRN and CRN
25
New cards
To achieve a T1 weighted image using a spin echo pulse sequence, the technologist should choose:
Short TE (minimum-20ms)
Short TR (300-600ms)
26
New cards
A spin echo (SE) exam is identified by its use of:
A. A variable excitation pulse followed by variable refocusing pulses
B. a 90 degree excitation pulse followed by one or more 180 degree refocusing pulses
C. a 90 degree excitation pulse followed by one or more gradient reversals
D. A variable excitation pulse followed by one or more gradient reversals
a 90 degree excitation pulse followed by one or more 180 degree refocusing pulses
27
New cards
The number of 180 degree rephrasing (refocusing) pulses is known as the:
A. Flip angle
B. Echo train length (ETL)
C. Receive bandwith
D. Number of excitations (NEX)
echo train length (ETL)
28
New cards
To correct for image blurring that may be associated with fast spin echo (FSE), a technologist may need to:
reduce the echo train length (ETL)
29
New cards

The pulse sequence that begins with a 180 degree pulse is known as a:
A. Inversion Recovery (IR)
B. Fast spin echo (FSE)
C. Gradient recalled echo (GRE)
D. Steady state free precession (SSFP)

inversion recovery (IR)

30
New cards
A STIR pulse sequence is useful because it reduces or eliminates signal from:
A. Muscle
B. Fat
C. CSF
D. Water
fat
31
New cards
A pulse sequence that uses a variable flip angle followed by gradient rephrasing is known as:
A. Gradient echo
B. Echo planar imaging
C. Spin echo
D. Inversion recovery
gradient echo
32
New cards
If a radiologist asks for a T2* exam, he/she wants a:
A. short TAU inversion recovery
B. fast spin echo
C. coherent or balanced gradient echo
D. spin echo
coherent or balanced gradient echo
33
New cards
Cardiac gating uses cardiac leads to ensure that the MRI signal is obtained:
A. at pre-determined timed intervals
B. at different phases of the cardiac cycle
C. at the same phase of the cardiac cycle
at the same phase of the cardiac cycle
34
New cards
The textbook suggests placing the white ECG lead:
in the midline on the superior aspect of the sternum
35
New cards
Signals of a good ECG trace include all of the following EXCEPT:
A. A regular rate- the PQRST complexes are spaced evenly apart
B. the R wave is significantly larger than the T wave
C. the P wave is significantly higher than the T wave
D. the PQRST complex has good amplitude
the P wave is significantly higher than the T wave
36
New cards
Introduction of the patient into the bore of the magnet may cause the following abnormality on trace images:
A. elevation of the T wave
B. reduction of the R wave
C. elevation of the P wave
D. widening of the QRS complex
elevation of the T wave
37
New cards
Regarding coil safety, the technologist should perform all of the following EXCEPT:
A. Tape the cables and pads to the side of the table
B. Place foam pads between the cables and the patient's chest
C. Ensure that the cables do not touch the bore when the patient is inside the magnet
D. Loop cables into coils to reduce excess cables outside the bore of the magnet
Loop cables into coils to reduce excess cables outside the bore of the magnet
38
New cards
Attaching a photo sensor to a finger or toe to detect the increase in blood volume in the capillary bed during systole is known as:
A. ECG Gating
B. Peripheral gating
C. cine imaging
D. respiratory compensation
peripheral gating
39
New cards
Cardiac gating requires a modification of the normal TR period. The TR period during cardiac gating is measured by the:
A. P wave to T interval
B. R wave to R wave interval
C. QRS to QRS complex interval
D. S wave to T wave interval
R wave to R wave interval
40
New cards
Which of the following is NOT a respiratory compensation technique?
A. peripheral gating
B. Navigators
C. Breath hold
D. Respiratory Gating
peripheral gating
41
New cards
Correct positioning of the respiratory bellows should be:
A. parallel to the iliac crests and positioned over the diaphragm
B. At an angle to catch both thoracic and abdominal movements during respiration
C. At an angle to catch respiratory movements in the abdomen and pelvis
D. Parallel to the iliac crests and positioned 1 inch superior to the umbilicus
at an angle to catch both thoracic and abdominal movements during respiration
42
New cards
In cine imaging, gradient moment nulling (GMN) may result in:
A. Decreased spatial resolution
B. increased flow artifacts
C. increased contrast to noise ration
D. decreased scan time
increased contrast to noise ratio
43
New cards
The most common positive contrast agent used in MRI is:
gadolinium
44
New cards
What is the effect on protons following the introduction of positive MRI contrast media?
A. water molecules spin faster
B. fat molecules spin faster
C. T1 and T2 relaxation times are reduced
D. The contrast media absorbs RF, allowing contrast to appear bright on the final image
T1 and T2 relaxation times are reduced
45
New cards
Positive contrast agents are most commonly used with what type of image weighting?
A. T1 contrast weighting
B. Neither T1 nor T2 contrast weighting
C. T2 contrast weighting
D. Both T1 and T2 contrast weighting
T1 contrast weighting
46
New cards
Gadolinium in its natural form is toxic to the body, so manufacturers combine it with ______________ to allow its expulsion from the body.
chelates
47
New cards
Which of the following is NOT a positive contrast agent?
A. Hyperpolarized helium
B. Iron oxide
C. Manganese
D. Gadolinium
iron oxide
48
New cards
Which of the following is NOT a negative contrast agent?
A. Air
B. Iron oxide
C. Gadolinium
D. Blueberry juice
gadolinium
49
New cards
According to the text, negative contrast agents are most often used to image:
A. Abdomen
B. extremities
C. brain
D. spine
abdomen
50
New cards
When performing MRI scans of the heart or vessels, the most effective contrast media choices are considered:
A. positive contrast agents
B. negative contrast agents
C. blood pool agents
D. All of the above
blood pool agents
51
New cards
Intravascular agents are unique in that they bind with:
A. hemoglobin
B. CSF
C. albumin
D. chelates
albumin
52
New cards
A sagittal image of the brain should include:
A. From the vermis to the vertex
B. from the foramen magnum to the top of the head
C. from the fourth ventricle to the top of the head
D. from the body of the mandible to the top of the corpus callosum
from the foramen magnum to the top of the head
53
New cards
Axial slices should be aligned:
A. Perpendicular to the anterior-posterior commissure axis
B. Parallel to the pons and medulla oblongata
C. Parallel to the tentorium cerebelli
D. Parallel to the anterior-posterior commissure axis
parallel to the anterior-posterior commissure axis
54
New cards
All head exams typically find the patient positioned
A. Supine, feet first, with the head in a flex coil
B. Supine, head first, with the head in the head coil
C. Prone, head first, with the head in the head coil
D. Prone, feet first, with the head in a flex coil
supine, head first, with the head in the head coil
55
New cards
The pulse sequence listed as especially useful for imaging the pediatric brain is:
A. Axial/oblique FSE T2
B. Sagittal SE T1
C. Axial/Oblique IR T1
D. Axial/Oblique FLAIR
Axial/oblique IR T1
56
New cards
FLAIR sequences are useful for their:
A. Increased signal from CSF
B. Suppression of signal from fat
C. Suppression of signal from CSF
D. Increased signal from fat
suppression of signal from CSF
57
New cards
Most tumor protocols require technologists to scan:
before and after contrast media administration
58
New cards
B-values are associated with what type of scan?
A. Fast spin echo (FSE)
B. echo planar imaging (EPI)
C. Gradient recalled echo (GRE)
D. Diffusion weighted imaging (DWI)
diffusion weighted imaging (DWI)
59
New cards
What is the typical b-value for imaging the brain?
A. 0
B. 500
C. 1500
D. 1000
1000
60
New cards
The most common pulse sequence utilized for acquiring proton density (PD) or T2 weighted images is a:
A. Fast spin echo (FSE)
B. FLAIR
C. spin echo (SE)
D. gradient recalled echo (GRE)
fast spin echo (FSE)
61
New cards
If a haemorrhagic lesion is suspected, what type of pulse sequence may be required?
A. Inversion recovery
B. Spin echo
C. Gradient echo (GRE)
gradient echo (GRE)
62
New cards
For the cervical spine, axial slices are prescribed:
A. with no angle
B. angled so they are perpendicular to the disc space
C. angled so they are parallel to the disc space
D. angled so they are parallel to the spinal cord
angled so they are parallel to the disc space
63
New cards
Sagittal images of the cervical spine should include:
A. the area from the base of the skull to the second thoracic vertebra
B. C1-T1
C. C2-C7
D. the area from the base of the skill to the 6th thoracic vertebra
the area from the base of the skull to the second thoracic vertebra
64
New cards
Based on the images found in your textbook, CSF on a T1 weighted image appears:
A. hyperintense to the spinal cord (bright)
B. isointense to the spinal cored (same)
C. hypointense to the spinal cord (dark)
hypointense to the spinal cord (dark)
65
New cards
Based on the images found in your text, a sagittal T2 weighted image shows CSF to be:
A. hyperintense to the spinal cord (bright)
B. isointense to the spinal cord (same)
D. hypointense to the spinal cord (dark)
hyperintense to the spinal cord (bright)
66
New cards
If bright CSF is desired on an axial image of the spine, then the technologist should choose:
A. FLAIR
B. spoiled gradient echo
C. T1 weighted FSE
D. Coherant gradient echo
coherent gradient echo
67
New cards
The most common and troublesome artifact in the cervical spine is the:
A. flow motion from CSF
B. arbitrary patient motion
C. swallowing motion
D. respiratory motion
flow motion from CSF
68
New cards
Coronal and sagittal slices of the thoracic spine should include anatomy from:
A. C6-the conus
B. C6-cauda equine
C. T1 through the cauda equine
D. C7- the conus
C7 through the conus
69
New cards
To correct for aliasing in the thoracic spine, the technologist should:
A. increase the FOV
B. decrease slice thickness
C. decrease the scan time
D. increase the NEX
increase the FOV
70
New cards
When imaging the lumbar spine, the technologist should include anatomy from:
A. the conus to the coccyx
B. the conus to the sacrum
C. the cauda equina to the sacrum
D. the cauda equina to the coccyx
the conus to the sacrum
71
New cards
The optimal imaging window for the evaluation of breast cancer is:
approximately 10 days post menses
72
New cards
How many hours should the patient wait prior to receiving a second dose of gadolinium (example: repeat exam)?
24 hours
73
New cards
Which of the following is NOT an obvious artifact when performing MRI of the chest?
A. respiratory motion
B. flow motion
C. cardiac motion
D. peristalsis
peristalsis
74
New cards
To improve image quality when scanning the chest, technologists should:
A. use a fine matrix
B. increase the slice gap
C. use a symmetrical FOV
D. use multiple NEX/NSA
use multiple NEX/NSA
75
New cards
Motion artifact will always occur along the:
A. slice select gradient
B. cannot be predicted
C. frequency encoding axis
D. phase encoding axis
phase encoding axis
76
New cards
When imaging the chest, technologists will reduce artifact from the aorta and IVC by applying spatial presaturation pulses:
A. superior and inferior to the FOV
B. across the heart
C. inferior to the chest
D. to the right and left of the FOV
superior and inferior to the FOV
77
New cards
Gradient moment nulling has the following effects on the MR image:
increases the minimum TE
reduces flow artifact
may be useful if bright blood is desired on GRE sequences
78
New cards
When prescribing slices for a four chamber view of the heart, the technologist should:
A. align parallel to the mitral valve
B. align parallel to the intraventricular septum
C. align perpendicular from the inferior border of the heart to the superior aspect of the arch of the aorta
D. align through the apex of the left ventricle and mitral valve
align through the apex of the left ventricle and mitral valve
79
New cards
Thymus imaging is generally acquired on:
pediatric patients
80
New cards
For brachial plexus imaging, axial slices are generally prescribed from:
A. the arch of the aorta to the third cervical vertebra
B. the arch of the aorta to the seventh cervical vertebra
C. the apex of the lungs to the base of the skill
the arch of the aorta to the third cervical vertebra
81
New cards
Axial slices of the liver should be prescribed:
A. from the ASIS to the arch of the aorta
B. from the pubis symphysis to the diaphragm
C. from the iliac crest to the arch of the aorta
D. from the inferior margin of the liver to the diaphragm
from the inferior margin of the liver to the diaphragm
82
New cards
For LIVER imaging, delayed scans after contrast enhancement are sometimes necessary to evaluate:
A. visualization of arterial and venous phases
B. enhancement of the kidneys
C. visualization of the gallbladder
D. enhancement and filling of the bladder
visualization of arterial and venous phases
83
New cards
For a MRCP, long TR and TE times serve to:
A. nullify the signal from all tissues except those with long T2 times
B. nullify the signal from all tissues except those with long T1 times
C. enhance the tissue from all tissues and vessels
D. enhance the signal from all tissues
nullify the signal from all tissues except those with long T2 times
84
New cards
The optimum TR for T1 weighted imaging of the liver is:
A. less than 400 ms
B. 400-800 ms
C. 1000-14000 ms
D. more than 2000 ms
less than 400 ms
85
New cards
As TR is decreased:
A. SNR is increased
B. available slices per acquisition are decreased
C. slice thickness is increased
D. FOV is decreased
available slices per acquisition are decreased
86
New cards
When scanning the kidneys, axial slices are prescribed from:
A. the inferior margin of the liver to the diaphragm
B. the iliac creast to the diaphragm
C. the inferior margin of the stomach to the arch of the aorta
D. the inferior margin of the kidneys to the superior aspect of the adrenals
the inferior margin of the kidneys to the superior aspect of the adrenals
87
New cards
Use of parallel imaging scan techniques will:
A. decrease scan time
B. have no affect on scan time
C. increase scan time
decrease scan time
88
New cards
What type of artifact is commonly seen around the kidneys, especially at high field strengths?
A. magic angle
B. truncation
C. peristalsis
D. chemical shift
chemical shift
89
New cards
To reduce peristalsis when scanning the pancreas:
A. bellows may be used
B. antispasmodic agents may be given
C. ECG gating may be used
D. pre-saturation pulses should be placed on the pancreas.
antispasmodic agents may be given
90
New cards
For contrast enhanced MRA studies, mid-term acquisitions demonstrate:
A. capillary phase
B. arterial phase
C. venous phase
capillary phase
91
New cards
Common indications for scanning of the male pelvis include all of the following EXCEPT:
A. infertility
B.cervical lesions
C. carcinoma
D.prostatic lesions
cervical lesions
92
New cards
The most common positioning for MRI scans of the pelvis require the patient be placed:
supine
93
New cards
If a local rectal coil is used, then it should be inserted:
A. after the localizer but before the exam sequences
B. after non-contrast images but before contrast images
C. it does not matter
D. prior to the start of the exam
prior to the start of the exam
94
New cards
(Select ALL that apply.) Which of the following sequences will BEST demonstrate female ovaries? Consider that both ovaries should be seen on the same image.
A. axial slices
B. sagittal slices
C. coronal slices
AXIAL AND CORONAL SLICES
95
New cards
Prostate imaging usually requires which of the following?
A. large FOV
B. thick slices
C. use of low resolution imaging
D. use of a rectal coil
use of rectal coil
96
New cards
To obtain sagittal images of the pelvis, the technologist should prescribe scans from:
A. the coccyx posteriorly to the anterior aspect of the pubis symphysis
B. from the pubic symphysis to the iliac crest
C. the left to the right pelvic side walls
D. the left greater trochanter to the right greater trochanter
the left to the right pelvic side walls
97
New cards
An axial image, that demonstrates a bright or hyperintense bladder, is mostly likely which of the following?
A. T1 weighted
B. T2 weighted
C. incoherent (spoiled) GRE
T2 weighted
98
New cards
(Select ALL that apply.) Fine matrix sizes in conjunction with short scan times can be acquired in the pelvis by using:
fast spin echo (FSE)
local/phased array/muli-array coils
rectangular FOV
surface coils
conventional spin echo (SE)
isotropic (square) FOV
fast spin echo (FSE)
local/phased array/muli-array coils
rectangular FOV
99
New cards
Gradient moment nulling (GMN) helps to reduce flow (motion) artifact, but is least beneficial during:
A. T2 weighted sequences
B. T1 weighted sequences
C. Gradient recalled echo (GRE) sequences
T1 weighted sequences
100
New cards
According to the authors of your textbook, when scanning the shoulder, the hand should be positioned so that the:
A. thumb is pointing up (neutral position)
B. thumb is pointing laterally (external rotation)
C. it does not matter
D. thumb is pointing down (internal rotation)
thumb is pointing up (neutral position)