1
New cards

Every fixture shall have what surface requirements?

A smooth, hard, corrosion-resistant surface free of flaws and blemishes that may interfere with cleaning.

2
New cards

How many shower heads may be served by a single shower drain?

6.

3
New cards

Where 2 or more shower heads are served by a shower drain, the floor shall be?

Sloped and the drain located so that water from one head cannot flow over the area that serves another head.

4
New cards

Except for column showers, when a battery of shower heads is installed, the horizontal distance between 2 adjacent shower heads shall be not less than?

750 mm.

5
New cards

A dishwashing sink and a food preparation sink shall not have?

Concealed overflows.

6
New cards

Every trap shall have a trap seal depth of not less than?

38 mm.

7
New cards

The trap seal depth on fixtures draining to an acid waster system shall be a minimum of?

50 mm.

8
New cards

A _____ trap shall not be installed in a drainage system.

Bell.

9
New cards

Except for a floor-mounted service sink, every trap that serves a lavatory, a sink or a laundry tray shall be provided with a?

Cleanout plug.

10
New cards

Except for a floor-mounted service sink, every trap that serves a lavatory, a sink or a laundry tray shall be provided with a cleanout plug or be designed so?

That part of the trap can be removed for cleaning purposes.

11
New cards

The cleanout plug located at the lowest point of the trap that serves a lavatory, a sink or a laundry tray shall be made of what material?

Same material as the trap, except that a cast-iron trap shall be provided with a brass cleanout plug.

12
New cards

A drum trap shall not be used as a fixture trap unless?

Its required to serve as an interceptor and access for servicing is provided.

13
New cards

Every interceptor shall be designed so that?

It can be readily cleaned.

14
New cards

Every grease insterceptor shall be designed so that it does not become _____, and not have a ______>

Air bound. Water jacket.

15
New cards

A T fitting shall not be used in a drainage system, except to ?

Connect a vent pipe.

16
New cards

A cross fitting shall not be used in a?

Drainage system.

17
New cards

A single or double sanitary T fitting shall not be used in a?

Nominally horizontal soil-or-waste pipe.

18
New cards

Since a single or double sanitary T fitting shall not be used in a nominally horizontal soil-or-waster pipe what fitting shall be used?

A single or double wye with a 45.

19
New cards

When can a single sanitary T fitting be sued in a nominally horizontal soil-or-waste pipe?

May be used to connect a vent pipe.

20
New cards

A double sanitary T fitting shall not be used to connect the trap arms of?

Back outlet water closets installed back-to back or 2 urinals where no cleanout fitting is provided above the connection.

21
New cards

90 elbows of 4" or less whose centre-line radius is less than the size of the pipe shall not be used to join?

2 soil-or-waste pipes.

22
New cards

For sanitary drainage systems of 4" or less, 90 elbows shall only be permitted to?

Change the direction of piping from horizontal to vertical in direction of flow, where a trap arm enters a wall, on water closet going from vertical to horizontal as well as on horizontal by itself.

23
New cards

Concrete fittings fabricated on the site from lengths of pipe shall?

Not be used.

24
New cards

Concrete pipe shall not be used where?

Above ground inside a building.

25
New cards

Vitrified clay pipe and fittings shall not be used except for?

An underground part of a drainage system.

26
New cards

Polyethylene water pipe shall not be used except for?

A water service pipe.

27
New cards

Transition solvent cement shall only be used for joining?

An ABS drainage system to a PVC drainage system.

28
New cards

Cast-iron soil pipe and fittings shall not be used in a?

Water system.

29
New cards

Threaded cast-iron drainage fittings shall not be used in a?

Water system.

30
New cards

Screwed cast-iron water fittings used in a water system shall be?

Cement-mortar lined or galvanized.

31
New cards

Screwed cast-iron water fittings shall not be used in a?

Drainage system.

32
New cards

Screwed malleable iron water fittings used in a water system shall be?

Cement-mortar lined or galvanized.

33
New cards

Screwed malleable iron water fittings shall not be used in a?

Drainage system.

34
New cards

Galvanized steel is permitted to be used where?

In a drainage system or a venting system above ground inside a building.

35
New cards

Galvanized steel pipe and fittings shall not be used in a water distribution system except?

In buildings of industrial occupancy or for the repair of existing galvanized steel piping systems.

36
New cards

Corrugated steel pipe shall only be used where?

Underground outside a building in a storm drainage system.

37
New cards

A sheet metal leader shall not be used except where?

Above ground outside a building.

38
New cards

Brass or bronze threaded water fittings shall not be used in a?

Drainage system.

39
New cards

Copper tube shall not be used for?

The fixture drain or the portion of the vent pipe below the flood level rim of a flush-valve-operated urinal.

40
New cards

Where can K & L hard temper copper be used?

Everywhere except for water service pipe and underground water distribution systems.

41
New cards

Where can K & L soft temper copper be used?

Water service pipe, underground and above-ground water distribution systems.

42
New cards

Where can M hard temper copper be used?

Above-ground water distribution systems, above-ground drainage systems and above-ground venting systems.

43
New cards

Where can M soft temper copper be used?

No where.

44
New cards

Where can DWV copper be used?

Above-ground drainage systems and above-ground venting systems.

45
New cards

Solder-joint fittings for drainage systems shall not be used in a?

Water system.

46
New cards

Lead waste pipe and fittings shall not be used in a?

Water system or as a building sewer.

47
New cards

When there is a change in size of a lead closet bend, the change shall be in the?

Vertical section of the bend or made in a manner that prevents the retention of liquid in the bend.

48
New cards

Cement mortar shall not be used for?

Jointing.

49
New cards

Solders and fluxes having a lead content in excess of 0.2% shall not be used in a?

Potable water system.

50
New cards

When screws, bolts, nuts and washers are used to connect a water closet to a water closet flange, to anchor the water closet flange to the floor or to anchor the water closet to the floor they shall be made of?

Corrosion-resistant materials.

51
New cards

Every plug, cap, nut or bolt that is intended to be removable from a ferrous fitting shall be of a?

Non-ferrous material.

52
New cards

A clean-out fitting that, as a result of normal maintenance operations, cannot withstand the physical stresses of removal and re-installation or cannot ensure a gas-tight seal shall?

Not be installed.

53
New cards

A saddle hub or fittings shall not be installed in?

Drainage, venting or water systems.

54
New cards

All mixing valves supplying shower heads shall be of what type?

Pressure-balanced, thermostatic, or combination pressure-balanced/thermostatic type.

55
New cards

All mixing valves supplying shower heads shall be capable of?

Maintaining a water outlet temperature that does not exceed 49 C, and limiting thermal shock.

56
New cards

The temperature of water discharging into a bathtub shall?

Not exceed 49 C.

57
New cards

The orifice of every drinking fountain bubbler shall?

Be of the shielded type and direct the water upward at an angle of 45.

58
New cards

Every drinking fountain bubble shall include a means of?

Regulating the flow to the orifice.

59
New cards

Bubblers shall be installed only on?

Drinking fountains.