18 Terms

1
New cards

Conduit, service conductors, panelboard, and overcurrent protective devices.

Electrical services consist of ___, ___, ___, and ___. (pg 304)

2
New cards

Service drop

If the power connects to the electric service overhead, the incoming service supply is referred to as a ___. (pg 304)

3
New cards

Service lateral

If the service is supplied underground, the supply is defined as a ___. (pg 304)

4
New cards

Cold sequence metering

When a disconnect is installed before the meter, it is known as ___. (pg 306)

5
New cards

Metal wireway

Sheet metal troughs with hinged or removable covers for housing and protecting electrical wires. (pg 308)

6
New cards

Busway

Metal enclosure containing factory-mounted bare or insulated conductors, which are usually copper or aluminum bars, rods, or tubes. (pg 309)

7
New cards

Cast aluminum, galvanized steel, or PVC.

Weatherheads may be of what materials? (pg 311)

8
New cards

Galvanized steel

Service masts are typically constructed of what material? (pg 311)

9
New cards

Panelboard

The final component in a commercial electrical service is the ___. (pg 311)

10
New cards

True

True or false: MLO panels do not have a main circuit breaker. (pg 311)

11
New cards

1,000V

A disconnect switch connected to the supply side of the meter (cold sequence) must be rated at no more than ___V. (pg 312)

12
New cards

Installed beneath the building encased in 2" of concrete or in conduit buried at least 18"

Conductors are considered outside of a building if ___ or ___. (pg 312)

13
New cards

13' 6"

The weatherhead or tie point for the service drop should be a minimum of ___ above final grade. (pg 313)

14
New cards

120/240V, single-phase

The most common service voltage for small commercial and other small loads is ___. (pg 314)

15
New cards

UL

Wire bending and connection space in distribution equipment is provided according to ___ standards. (pg 305)

16
New cards

400A and above

A group of CTs, one for each ungrounded conductor or set of conductors, is typically used in services rated ___.

17
New cards

Withstand torque of a fault current

Bracing of busbars is required primarily to ___.

18
New cards

False

True or false: Occupants are NOT required to have their own disconnecting means as per NEC 230.72(C). (pg 326)