What is defined as a program used to systematically monitor and evaluate the quality of services within an imaging department

quality assurance program

2
New cards

T/F: Continuous Quality Improvement (CQI) is part of the Quality Assurance (QA) process?

True

3
New cards

____ ____ focuses specifically on imaging equipment, acessories, and the images produced

quality control

4
New cards

T/F: equipment is routinely tested to make sure it is functioning properly

True

5
New cards

What do we use to help maintain image quality while keeping repeat exams and unnecessary patient exposure as low as possible

quality control

6
New cards

What are the 3 steps of the quality control program?

  1. Acceptance testing

  2. Routine performance monitoring

  3. Maintenance


7
New cards

This part of quality control occurs when equipment is installed to make sure it is operating properly

acceptance testing

8
New cards

This part of quality control occurs when there is routine testing to make sure equipment continues to function properly over time

routine performance monitoring

9
New cards

This part of quality control is performed to prevent problems

preventative maintenance

10
New cards

This part of quality control is performed after a probelm occurs

repair/error maintenance

11
New cards

____ removes low-energy photons that would be absorbed by the patient without contributing useful information to the image

filtration

12
New cards

What is an important patient-protection feature of the imaging system?

filtration

13
New cards

What are the 3 types of filtration?

  1. inherent - already in the tube housing and collimator

  2. added - aluminum placed in the path of the beam

  3. total - inherent + added


14
New cards

T/F: filtration can directly be measured

False, it cannot be measured directly

15
New cards

_____ is the thickness of absorbing material needed to reduce the intensity of the beam to one-half of its original value

HVL (half value layer)

16
New cards

How often is filtration and HVL evaluated?

annually or when changed to the tube or housing are made

17
New cards

T/F: the light field should accurately represent the area that will be exposed by the x-ray beam

True

18
New cards

This is referred to as an automatic collimation system

PBL (positive beam limitation)

19
New cards

T/F: PBL senses the size of the IR and adjusts the collimator shutters to match it

true

20
New cards

What is light field-radiation field congruence?

it determines whether the area shown by the positioning light matches the area exposed

21
New cards

How do we test for congruence?

  • a collimator test tool

  • the 8-penny test


22
New cards

How often should collimation be evaluated?

semiannually

23
New cards

_____ provides a simple method of evaluating collimator accuracy without a specialized collimation test tool

8-penny test

24
New cards

What type of equipment is transportable to the patients bedside or the operating room?

mobile equipment

25
New cards

What are the different types of mobile x-ray units?

  • direct

  • battery

  • Capacitor-discharge

  • High-frequency


26
New cards

T/F: C-arm mobile units have the ability to do fluoroscopy

True

27
New cards

T/F: when using a fluoroscopic unit, the tube is under the patient and the image intensifier is above the patient

True

28
New cards

Why is the tube under the patient in fluroscopy?

to reduce operator exposure

29
New cards

This type of x-ray unit is designed to image curved surfaces by moving around a stationary patient (ex. mandible)

panoramic

30
New cards

Where is a panoramic x-ray unit typically used?

in dentistry

31
New cards

_____ evaluates patients bone mineral density and mass for evidence of osteoporosis

bone densitometry

32
New cards

What is the most common procedure?

DEXA

33
New cards

T/F: the beam should be parallel when the tube is positioned perpendicular

False, the beam should be perpendicular

34
New cards

What can improper beam alignment cause?

  • image distortion

  • clipped anatomy

  • grid cutoff


35
New cards

Imaging systems must have a minimum filtration of ___ mm Al

2.5 mm Al

36
New cards

The light field must ve congruent within ___% of the SID

2%

37
New cards

Beam alignment must be within __% of the SID

1%

38
New cards

Distance indicator must be within ___% of the actual SID

2%

39
New cards

Centering must be accurate within ___% of the SID

1%

40
New cards

Spatial resolution is determined by the ____

FSS

41
New cards

Which produces better spatial resolution a small or large focal spot

small focal spot

42
New cards

How often should FSS be evaluated?

when new equipment is installed, a tube is replaced, or annually


43
New cards

Pinhole camera, star pattern, and slit camera are tools used to measure ___

FSS

44
New cards

This way to measure FSS is difficult to use and requires excessive exposure times

Pinhole camera

45
New cards

This way to measure FSS is easiest to use but is limited in size

star pattern

46
New cards

This way to measure FSS is considered the gold standard

slit camera

47
New cards

This is an example of what tool used to measure FSS?


Pinhole

48
New cards

This is an example of what tool used to measure FSS?

Slit camera

49
New cards

____ can be used instead of directly measuring FSS when evaluating spatial resolution

line-pair test tool

50
New cards

The _____ test tool shows how well the imaging system can distinguish between small objects that are close together

line-pair

51
New cards

Who checks the accuracy of kVp?

medical physicist

52
New cards

What 3 things does kVp accuracy affect?

  • patient dose

  • image quality

  • radiographic contrast


53
New cards

What are the most common devices used to measure accuracy of kVp

filtered ion chambers or filtered photodiodes

54
New cards

How often should kVp accuracy be evaluted?

annually or after changes to high-voltage generator components

55
New cards

It only takes a ___% change in kVp to affect optical density and radiographic contrast

4%

56
New cards

When testing, the measured kVp should be within ___% of the indicated kVp

10%

57
New cards

Exposure time is the responsibility of who?

the technologist

58
New cards

Exposure time affects both ____ and ___

patient dose and image production

59
New cards

Who evaluated the exposure timer and how often?

medical physicist annually

60
New cards

T/F: regardless of material thickness and exposure time, the exposure of the processed image should be constant

True

61
New cards

___ performance can be evaluated by exposing an image receptor through different thicknesses of aluminum or acrylic

AEC

62
New cards

___ acts as a safety feature if the AEC fails to terminate the exposure.

AEC backup timer

63
New cards

How is the backup timer tested?

by placing a lead filter in the beam

64
New cards

____ describes the ability of the x-ray unit to produce a consistent radiation output using different combinations of mA and exposure time

exposure linearity

65
New cards

A ____ is used to measure radiation output

dosimeter

66
New cards

exposure linearity radiation output for adjacent mA stations should be within ___%

10%

67
New cards

____ the ability of the radiographic unit to replicate an exposure using the same technique

Exposure reproducibility

68
New cards

Exposure reproducibility radiation output should not vary by more than ___%

5%

69
New cards

How often is lead protective apparel evaluated?

annually

70
New cards

What type of damages can occur to protective apperal?

  • cracking

  • tearing

  • bunching


71
New cards

T/F: you should avoid folding lead aprons

true

72
New cards

____ is defined as an undesirable and usually unexpected event caused by medical management rather than the patient’s underlying disease or condition

adverse event

73
New cards

What are some examples of adverse events?

  • patient falls

  • improper medication administration

  • procedure complications


74
New cards

T/F: an adverse event requires there to be permanent damage to the patient

False, it does not have to be permanent

75
New cards

____ is defined as an unexpected occurrence involving death or serious physical or psychological injury, or the risk thereof

sentinel event

76
New cards

What type of events are serious enough to require immediate investigation and response.

Sentinel events

77
New cards

T/F: exposure techniques differ between mobile units

True

78
New cards

T/F: the longer the fluoroscopy time, the greater the radiation exposure

true

79
New cards

What does a DEXA commonly scan?

lower spine and hips

80
New cards

The ___ compares the patients bone density to a young healthy adult

T-score

81
New cards

The ___ compares the patients bone density to adults of similar age

Z-score

82
New cards

T/F: positioning is critical when performing DEXA scans

True

83
New cards

T/F: breast tissue attenuates the x-ray beam similarly

True

84
New cards

What kVp and mAs should be used when imaging the breasts?

low kVp and high mAs since there is not a lot of contrast (24-34 kVp)

85
New cards

Compression during mammography helps to make breast thickness ___, reduce ___, and increase ____

uniform, scatter, spatial resolution

86
New cards

_____ can be used to better visualize very small structures but also causes increased radiation exposure

magnification

87
New cards

____ is a 3D mammography that is similar to CT

DBT (digital breast tomosynthesis)

88
New cards

What is being performed when an x-ray tube moves over the compressed breast from one side to the other creating multiple images from different angles

DBT (digital breast tomosynthesis)

89
New cards

T/F: DBT may improve detection of abnormalities and reduce false-positives

true

90
New cards

Which has a higher breast radiation dose, conventional mammography or digital breast tomosynthesis

digital breast tomosynthesis

91
New cards

____ uses movement to intentionally blur anatomy above and below the plane of interest

linear tomography

92
New cards

Linear tomography has largely been replaced by what imaging modality?

CT

93
New cards

The ____ angle is the arc created by the total movement of the x-ray tube

tomograohic

94
New cards

The ___ lies within the plane of the anatomic area to be imaged (the pivot point of the tomographic movement)

fulcrum

95
New cards

The ___ plane contains the area of interest

object

96
New cards

T/F: exposure time must be increased and a low mA must be used to achieve blurring

true

97
New cards

To achieve maximum blurring in linear tomography, the AOI should be ____ to the direction of movement

perpendicular

98
New cards

When performing linear tomography, structures that are parallel to the motion can appear as _____

streaks

99
New cards

T/F: the fulcrum is fixed

false, it can be fixed or adjustable