108 vocabulary flashcards covering EPA Section 608 Type I Certification topics including refrigerant recovery procedures, equipment standards, and legal requirements for small appliances.
Name | Mastery | Learn | Test | Matching | Spaced | Call with Kai | Chat |
|---|
No analytics yet
Send a link to your students to track their progress
Type I Appliance Maximum Charge
A maximum allowable factory charge of 5pounds of refrigerant.
Small Appliance (EPA Definition)
Products manufactured, fully charged, and hermetically sealed in a factory containing 5lbs or less of refrigerant.
Self-Contained Recovery (Operating Compressor)
Requirement to recover at least 90% of the nameplate charge or achieve 4inches of mercury vacuum.
Refrigerant Mixing Policy
Refrigerants cannot be mixed in any appliance or recovery cylinder.
Passive System-Dependent Recovery
A process for small appliances that captures refrigerant in a non-pressurized container.
Defrost Heater
Used to speed recovery from a frost-free refrigerator by vaporizing liquid refrigerant.
Mixed Refrigerant Handling
Reclamation facilities may refuse to accept a tank or charge extra for processing it.
Refrigerator Access Valves
Installed on both high and low sides to improve the speed of recovery.
Process Stub
A straight piece of tubing on small appliances typically used for piercing access valves.
HCFC or HFC System-Dependent Limit
The maximum normal charge allowed to use system dependent recovery equipment is 15pounds.
Restricted Capillary Tube Recovery
Requires only one access valve on the high side of the system if the compressor is operating.
Passive Recovery Permissibility
Permissible for recovery from domestic refrigerators.
R-600a
An approved hydrocarbon refrigerant for new household refrigerators, freezers, and combination refrigeration/freezers.
Hydrocarbon Retrofitting
Hydrocarbons are not approved for retrofit applications into existing household refrigerators.
Releasing Trapped Refrigerant from Oil
Essential when using passive recovery devices on small appliances with non-operating compressors.
Access Fitting Testing
Fittings should be leak tested after installation and before proceeding with recovery.
Zero psig System Pressure
Indicates that refrigerant recovery is not required.
System-Dependent Recovery Limit
Applicable only to appliances containing 15pounds of refrigerant or less.
Charging Cylinder Venting
Vapor vented off the top of the cylinder must be recovered.
Non-condensable Example
Air is a primary example found in refrigeration systems.
Small Appliance Leak Repair
EPA does not require repair, but recommends doing so whenever possible.
Recovery (Non-Operating Compressor)
Equipment must recover 80% of the refrigerant or achieve 4inches of vacuum.
System Flushing Agent
Nitrogen can be used to flush the system after refrigerant has been recovered.
Type I Certification
Required for persons handling refrigerant during maintenance, service, or repair of small appliances.
New Domestic Small Appliance HC
R−600a is an approved hydrocarbon for use in these NEW systems.
Passive Recovery (Non-Operating Compressor)
Technicians should place access fittings on both the low and high sides of the system.
Passive Recovery (Operating Compressor)
Technicians should run the compressor and recover from the high side only.
RV Refrigerants
Ammonia, Hydrogen, and water; these should not be recovered.
Recovery Equipment Certification
Must be certified by an EPA-approved testing laboratory.
Compressor Heat Gun Application
Used to help vaporize trapped liquid refrigerant during the recovery process.
Active Recovery Equipment
Equipment that has its own independent means to recover refrigerant.
Small Appliance Service Certification
Personnel must hold Type I or Universal certification.
Technician Regulation Responsibility
The technician is responsible for complying with any future changes to EPA regulations.
Reclaiming Mixed Refrigerants
Mixing multiple refrigerants in the same cylinder makes them unreclaimable.
Recovery Odor (Strong)
A strong odor detected during recovery usually indicates a compressor burnout.
Deep Vacuum Precaution
The compressor should never be energized while the system is in this state.
R-12/R-22 Thermal Decomposition
Exposure to open flames or hot surfaces can form phosgene gas.
R-134a
The most common replacement for R−12 in new household refrigerators.
Certification Manufacturing Date
Recovery equipment manufactured after November 15, 1993 must be certified by an EPA laboratory.
Type I Charge Threshold
5pounds is the maximum factory charge for appliances classified as Type I.
Solderless Piercing Valves
Should not remain on systems after repairs because they tend to leak over time.
Nitrogen Usage Rule
Only nitrogen vapor should be used for pressurizing or clearing debris.
Cylinder Pressure Reading Accuracy
Important to ensure the refrigerant is stable at room temperature for an accurate reading.
ARI 740-1993
The standard that recovery devices manufactured after November 15, 1993 must meet.
Shipping Standards
Refillable tanks for recovered refrigerants must meet Department of Transportation standards.
R-22 Pressure at 75∘F
Pressurized to 130psig in the absence of non-condensables.
Refrigerant Type Determination
The necessary first step before beginning any refrigerant recovery procedure.
Section 608 Regulated Refrigerants
Refrigerants such as R−12 must be recovered using certified equipment.
Large Refrigerant Release Action
Requires leaving the area or using self-contained breathing apparatus (SCUBA).
Maintenance (Recovery Device)
Regularly checking for refrigerant leaks.
Pungent Odor
Detectable during recovery when a compressor burnout has occurred.
Recovery Aid (Inoperative Compressor)
It is necessary to heat and strike the compressor with a rubber mallet.
Refrigerant Suffocation Hazard
Refrigerants are heavier than air and displace oxygen in contained areas.
Non-Type I MVAC systems
An MVAC-like system holding 3pounds of R−12 is not a Type I appliance.
R-500 Recovery
Must be recovered into its own dedicated vessel or one already containing R−500.
Service Manifold Practices
Use hand valves or self-sealing hoses to minimize refrigerant release.
Certification Renewal
EPA Section 608 certification has no expiration date.
R-12 Drop-In Substitute
There is no direct service drop-in substitute available for small appliances.
Piercing Valve Material Limit
Should only be used on copper or aluminum tubing.
PTAC
Packaged terminal air conditioners with 5pounds or less of refrigerant, certified under Type I.
R-500 Pressure at 75∘F
Pressurized to 95psig in the absence of non-condensables.
Very-High-Pressure Appliance
Liquid phase saturation pressure above 355psia at 104∘F.
R-22 Drop-In Substitute
There is no direct service drop-in substitute for R−22 in small appliances.
Enclosed Spill Procedure
Technicians should vacate and ventilate the spill area.
R-12 Pressure at 75∘F
Pressurized to 75psig in the absence of non-condensables.
Nitrogen Tank Accessory
Must always be equipped with a regulator.
Active Recovery Vapor Draw
Draw from the high side to avoid accidental liquid removal from a vapor-only device.
Nitrogen Venting
Venting is allowed when nitrogen is used for pressurizing or blowing debris.
Low Loss Fittings
Used to prevent refrigerant loss from hoses when they are disconnected.
Sale of Refrigerants
Restricted to technicians who are EPA certified in refrigerant recovery.
R-410A Pressure at 90∘F
Pressurized to 300psig in the absence of non-condensables.
DOT Regulation 49 CFR
Requires number of cylinders of each gas recorded for hazard class 2.2 shipping papers.
Process Tube
A service aperture consisting of a straight piece of tubing on small appliances.
Appliance Service Port
Required on all appliances for adding or removing refrigerant.
Phosgene Gas Formation
Gas formed when R−12 and R−22 decompose at high temperatures.
Hydrochloric Acid
One of the acids formed from thermal decomposition of R−12 or R−22.
Hydrofluoric Acid
An acid product resulting from the decomposition of refrigerants at high temperatures.
Active Recovery High Side Pressure
Caused by non-condensables in the recovery cylinder or an un-opened inlet valve.
Small Appliance Exception (Self-Contained)
Persons working only on small appliances are exempt from keeping a self-contained machine at the shop.
System Flushing
Using nitrogen after recovery to clean the refrigeration cycle.
Type I Recovery Personal Scope
Applicable for maintenance, service, or repair of small appliances.
CFC Recovery Standard
Requires certification by an EPA-approved testing laboratory for equipment.
Vaporization (Frost-free Fridge)
Turning on the defrost heater to vaporize any trapped liquid refrigerant.
Cylinder Stabilization
The procedure of allowing cylinder temperature to reach room temperature before pressure checks.
Vacuum Pump Limit
Can only be used as a recovery device with a non-pressurized container.
Reclamation Mix Management
Options include refusing the mix or charging extra for special processing.
Self-Sealing Hoses
Equipment used to minimize refrigerant release during manifold connection.
Safe Work Practices (EPA)
Standard safety measures like wearing gloves and safety glasses during service.
Copper and Aluminum Tubing
The only materials on which piercing-type valves should be used.
Passive Recovery Side Access
Required on both the high and low side if the system compressor does not run.
Vented Vapor Recovery
Compulsory recovery of vapor from charging cylinders.
EPA Disposal Rule (Post-93)
Disposal recovery for small appliances requires using ARI 740-1993 certified equipment.
Hazard Class 2.2
Category for Non Flammable Compressed Gases on DOT shipping papers.
Mercury Vacuum (Standard)
4inches is the target for both operating and non-operating compressor recovery.
Nameplate Charge (Target)
90% is the recovery objective when the compressor is operating.
Liquid Pressure Saturation (VHP)
Pressure above 355psia at 104∘F defines a Very-High-Pressure appliance.
Refrigerant Displacement
The process by which leaking refrigerant displaces oxygen, leading to suffocation.
Burnout detection method
Detection of a pungent or strong odor during a system recovery.
Process Stub Access
The location where a piercing-type access valve is installed.
80 percent capture
The minimum recovery standard for small appliances with an inoperative compressor.