Rad Physics-Chapter 8

0.0(0)
Studied by 0 people
call kaiCall Kai
Locked
learnLearn
examPractice Test
spaced repetitionSpaced Repetition
heart puzzleMatch
flashcardsFlashcards
GameKnowt Play
Card Sorting

1/24

flashcard set

Earn XP

Description and Tags

Vocabulary flashcards covering key terms, circuit components, generator types, and timers in x-ray machine circuitry.

Last updated 10:26 PM on 9/14/26
Name
Mastery
Learn
Test
Matching
Spaced
Call with Kai
Chat

No analytics yet

Send a link to your students to track their progress

25 Terms

1
New cards

Autotransformer

A transformer component located in the control console circuit that allows selection of major and minor kilovoltage peak (kVp\text{kVp}).

2
New cards

Line Voltage Compensator

A circuit device that compensates for fluctuations in incoming electrical line voltage (typically 220V220\,V to 240V240\,V AC) to ensure consistent radiographic exposure techniques.

3
New cards

High-Voltage Step-Up Transformer

A step-up transformer with a turns ratio between 500:1500:1 and 1000:11000:1 that converts low voltage from the autotransformer into high kilovoltage required for x-ray production.

4
New cards

Diode

A two-pole electronic rectifying component containing positive (pp) and negative (nn) semiconductor materials that allows electric current to flow in only one direction.

5
New cards

Rectifier Bridge

An arrangement of rectifying diodes that converts alternating current (AC) into direct current (DC) before it enters the x-ray tube.

6
New cards

Coolidge Tube

An improved x-ray tube developed by William Coolidge in 1913 that replaced Edison's carbonized cotton filament with a tungsten filament, enabling thermionic emission.

7
New cards
<p>Thermionic Emission</p>

Thermionic Emission

The process of heating the x-ray tube filament wire to extreme temperatures prior to exposure in order to boil off free electrons.

8
New cards

Filament Current

A low-voltage (5V\approx 5\,V), high-amperage (5A\approx 5\,A) current that flows through the filament wire to heat it whenever the rotor button is pressed.

9
New cards

Tube Current

The high-voltage current that propels freed electrons across the x-ray tube gap from the cathode filament to the anode during an exposure.

10
New cards

Filament Step-Down Transformer

A step-down transformer in the filament circuit with a typical turns ratio of 1:441:44 that reduces incoming voltage to about 5V5\,V to produce high current amperage.

11
New cards
<p>Ohm's Law</p>

Ohm's Law

The fundamental electrical relationship stating that voltage (VV) equals current (II) multiplied by resistance (RR), expressed as V=I×RV = I \times R.

12
New cards

Pre-Reading kVp Meter

A voltmeter connected in parallel before the step-up transformer in the console circuit to safely measure set kilovoltage without shock hazards.

13
New cards

mA Meter

An ammeter positioned in the secondary winding of the high-voltage step-up transformer to measure the true tube current flowing across the x-ray tube.

14
New cards

Voltage Ripple

The percentage variation in voltage waveform amplitude from peak voltage down to minimum voltage during electrical generation.

15
New cards

Single-Phase Generator

A generator utilizing 4 rectifying diodes that results in 100%100\% voltage ripple and an average beam energy of approximately 33%33\% of the set peak kilovoltage (kVp\text{kVp}).

16
New cards

Three-Phase 6-Pulse Generator

An x-ray generator producing 6 overlapping electricity pulses per cycle, yielding a 14%14\% voltage ripple and an average energy of approximately 91%91\% of the set kVp\text{kVp}.

17
New cards

Three-Phase 12-Pulse Generator

An x-ray generator producing 12 overlapping pulses per cycle, resulting in a 4%4\% voltage ripple and an average energy of approximately 97%97\% of the set kVp\text{kVp}.

18
New cards

High-Frequency Generator

An advanced x-ray generator that increases incoming waveform frequency to between 500Hz500\,\text{Hz} and 25,000Hz25,000\,\text{Hz}, achieving a voltage ripple of less than 1%1\% and an average voltage essentially equal to peak kVp\text{kVp}.

19
New cards

Generator Power Rating

A measurement of maximum generator power expressed in kilowatts (kW\text{kW}), calculated as mA×kVp1000\frac{\text{mA} \times \text{kVp}}{1000} for three-phase equipment and 0.7×mA×kVp1000\frac{0.7 \times \text{mA} \times \text{kVp}}{1000} for single-phase equipment.

20
New cards

Synchronous Motor Timer

A manual exposure timer driven by a synchronous motor spinning at 60 revolutions per second, capable of minimum exposure times of 160s\frac{1}{60}\,s.

21
New cards

Electronic Timer

A precision manual exposure timer that terminates exposure when a capacitor reaches a preset charge level, allowing times as short as 1ms1\,\text{ms} (11000s\frac{1}{1000}\,s).

22
New cards

mAs Timer

A timer circuit commonly used on mobile x-ray units that automatically selects the highest safe mA\text{mA} and terminates exposure when the preset cumulative mAs\text{mAs} is accumulated.

23
New cards

Automatic Exposure Control (AEC)

An automated exposure termination system that measures radiation reaching detectors behind the patient and automatically terminates the x-ray exposure once a preset electric charge threshold is accumulated.

24
New cards
<p>Gas Ionization Chamber</p>

Gas Ionization Chamber

A thin, rectangular radiation detector chamber containing air between two sheets of plexiglass, typically arranged in a triad configuration beneath the tabletop or upright bucky.

25
New cards
<p>Thyratron</p>

Thyratron

The exposure density control component on the console circuit that presets the required charge limit on an AEC capacitor before triggering the relay switch to shut off exposure.